{"id":954,"date":"2026-09-29T18:08:12","date_gmt":"2026-09-29T18:08:12","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=954"},"modified":"2026-09-29T18:08:18","modified_gmt":"2026-09-29T18:08:18","slug":"vo-bwc-armoured-cable-gland","status":"publish","type":"product","link":"https:\/\/yocl.com\/ar\/product\/vo-bwc-armoured-cable-gland\/","title":{"rendered":"BWC Cable Gland"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>YOCL ELECTRIC BWC Cable Glands are armoured cable glands for steel wire armoured (SWA) cable in dry indoor installations. The catalogue describes a brass body, with or without nickel plating, and mechanical retention of the cable armour. Thirteen models are listed with metric and NPT thread references.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Armour retention:<\/strong> the assembly is designed to grip armoured cable at the equipment entry.<\/li>\n<li><strong>Brass body options:<\/strong> plain brass or nickel-plated brass as described in the catalogue.<\/li>\n<li><strong>IP2X without a shroud:<\/strong> the protection grade stated for the BWC gland without the optional shroud.<\/li>\n<li><strong>Model-specific installation torque:<\/strong> torque values are supplied for the listed models.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0633\u0644\u0633\u0644\u0629 \u0627\u0644\u0645\u0646\u062a\u062c<\/td>\n<td>BWC<\/td>\n<\/tr>\n<tr>\n<td>Cable type<\/td>\n<td>Steel wire armoured (SWA)<\/td>\n<\/tr>\n<tr>\n<td>Body material<\/td>\n<td>Brass; nickel-plated brass option<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection<\/td>\n<td>IP2X without a shroud<\/td>\n<\/tr>\n<tr>\n<td>Intended environment<\/td>\n<td>Dry indoor<\/td>\n<\/tr>\n<tr>\n<td>Thread reference columns<\/td>\n<td>Metric and NPT<\/td>\n<\/tr>\n<tr>\n<td>Referenced standard<\/td>\n<td>BS 6121, as stated in the catalogue<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>13<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The table reproduces the source dimensions and installation torque by model. A and B are separate catalogue cable measurements; confirm their measurement points on the cable before selecting a gland. The NPT column lists alternatives where supplied. A dash means the source does not provide a value. All dimensional values are millimeters; torque is N\u00b7m.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Size<\/th>\n<th>Metric thread C<\/th>\n<th>Metric min D<\/th>\n<th>NPT C<\/th>\n<th>NPT min D<\/th>\n<th>Cable max A<\/th>\n<th>Cable min B<\/th>\n<th>Cable max B<\/th>\n<th>Max length E<\/th>\n<th>Armour min F<\/th>\n<th>Armour max F<\/th>\n<th>Max hex flats<\/th>\n<th>Max hex corners<\/th>\n<th>Torque (N\u00b7m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VO-BWC001<\/td>\n<td>0-20S<\/td>\n<td>M20\u00d71.5<\/td>\n<td>10<\/td>\n<td>1\/2 or 3\/4<\/td>\n<td>15<\/td>\n<td>12.0<\/td>\n<td>11.5<\/td>\n<td>16.0<\/td>\n<td>23.0<\/td>\n<td>0.90<\/td>\n<td>1.25<\/td>\n<td>22<\/td>\n<td>25<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC002<\/td>\n<td>1-20<\/td>\n<td>M20\u00d71.5<\/td>\n<td>10<\/td>\n<td>1\/2 or 3\/4<\/td>\n<td>15<\/td>\n<td>15.0<\/td>\n<td>14.5<\/td>\n<td>20.5<\/td>\n<td>26.0<\/td>\n<td>0.90<\/td>\n<td>1.25<\/td>\n<td>25\/27<\/td>\n<td>28\/30<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC003<\/td>\n<td>2-25<\/td>\n<td>M25\u00d71.5<\/td>\n<td>10<\/td>\n<td>1\/2 or 1<\/td>\n<td>15\/19<\/td>\n<td>20.0<\/td>\n<td>20.5<\/td>\n<td>26.5<\/td>\n<td>29.0<\/td>\n<td>1.25<\/td>\n<td>1.60<\/td>\n<td>35<\/td>\n<td>39<\/td>\n<td>50.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC004<\/td>\n<td>3-32<\/td>\n<td>M32\u00d71.5<\/td>\n<td>10<\/td>\n<td>1 or 1\u00bc<\/td>\n<td>19<\/td>\n<td>26.5<\/td>\n<td>26.5<\/td>\n<td>33.5<\/td>\n<td>32.0<\/td>\n<td>1.60<\/td>\n<td>2.00<\/td>\n<td>42<\/td>\n<td>47<\/td>\n<td>70.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC005<\/td>\n<td>4-40<\/td>\n<td>M40\u00d71.5<\/td>\n<td>15<\/td>\n<td>1\u00bc or 1\u00bd<\/td>\n<td>19\/21<\/td>\n<td>34.0<\/td>\n<td>33.0<\/td>\n<td>42.5<\/td>\n<td>36.0<\/td>\n<td>1.60<\/td>\n<td>5.00<\/td>\n<td>52<\/td>\n<td>59<\/td>\n<td>90.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC006<\/td>\n<td>5-50<\/td>\n<td>M50\u00d71.5<\/td>\n<td>15<\/td>\n<td>1\u00bd or 2<\/td>\n<td>21<\/td>\n<td>44.5<\/td>\n<td>42.5<\/td>\n<td>52.5<\/td>\n<td>45.0<\/td>\n<td>2.00<\/td>\n<td>2.50<\/td>\n<td>65<\/td>\n<td>73<\/td>\n<td>100.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC007<\/td>\n<td>6-63<\/td>\n<td>M63\u00d71.5<\/td>\n<td>15<\/td>\n<td>2 or 2\u00bd<\/td>\n<td>21\/30<\/td>\n<td>56.5<\/td>\n<td>52.5<\/td>\n<td>65.5<\/td>\n<td>50.0<\/td>\n<td>2.00<\/td>\n<td>2.50<\/td>\n<td>80<\/td>\n<td>90<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC008<\/td>\n<td>7-75<\/td>\n<td>M75\u00d71.5<\/td>\n<td>15<\/td>\n<td>2\u00bd or 3<\/td>\n<td>30\/32<\/td>\n<td>67.5<\/td>\n<td>65.5<\/td>\n<td>78.0<\/td>\n<td>60.0<\/td>\n<td>2.50<\/td>\n<td>3.15<\/td>\n<td>96<\/td>\n<td>108<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC009<\/td>\n<td>8-80<\/td>\n<td>M80\u00d72.0<\/td>\n<td>20<\/td>\n<td>3<\/td>\n<td>32<\/td>\n<td>74.0<\/td>\n<td>78.0<\/td>\n<td>82.0<\/td>\n<td>65.0<\/td>\n<td>2.50<\/td>\n<td>3.15<\/td>\n<td>96<\/td>\n<td>108<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC010<\/td>\n<td>9-90<\/td>\n<td>M90\u00d72.0<\/td>\n<td>20<\/td>\n<td>3 or 3\u00bd<\/td>\n<td>32\/33<\/td>\n<td>81.5<\/td>\n<td>82.0<\/td>\n<td>91.0<\/td>\n<td>69.0<\/td>\n<td>3.00<\/td>\n<td>3.50<\/td>\n<td>111<\/td>\n<td>125<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC011<\/td>\n<td>10-100<\/td>\n<td>M100\u00d72.0<\/td>\n<td>20<\/td>\n<td>3\u00bd or 4<\/td>\n<td>33\/34<\/td>\n<td>91.0<\/td>\n<td>90.0<\/td>\n<td>100.0<\/td>\n<td>88.0<\/td>\n<td>3.00<\/td>\n<td>3.50<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC012<\/td>\n<td>11-110<\/td>\n<td>M110\u00d72.0<\/td>\n<td>20<\/td>\n<td>4<\/td>\n<td>34<\/td>\n<td>98.0<\/td>\n<td>100.0<\/td>\n<td>114.0<\/td>\n<td>88.0<\/td>\n<td>3.00<\/td>\n<td>4.00<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>120.0<\/td>\n<\/tr>\n<tr>\n<td>VO-BWC013<\/td>\n<td>12-120<\/td>\n<td>M120\u00d72.0<\/td>\n<td>20<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>103.0<\/td>\n<td>103.0<\/td>\n<td>118.0<\/td>\n<td>100.0<\/td>\n<td>3.00<\/td>\n<td>4.00<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<td>120.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/bwc-cable-gland-dimension.webp\" alt=\"BWC Cable Gland dimension drawing\"><\/p>\n<h2>Selection Guide<\/h2>\n<p>Match the entry thread to the equipment, then check the cable\u2019s inner and outer sheath dimensions and armour thickness against the A, B and F values. Confirm available thread engagement, maximum installed length and tool clearance before specifying the model.<\/p>\n<h2>Installation Notes<\/h2>\n<p>The supplied assembly sequence is summarized below. Use the model-specific torque in the table for the outer-to-inner gland connection.<\/p>\n<ol>\n<li>Measure the cable\u2019s inner and outer sheaths with a dimension tape.<\/li>\n<li>Cut back the outer sheath to expose the armour, keeping the exposed length no longer than the outer component.<\/li>\n<li>Remove the locknut, then slide the shroud and outer component over the cable.<\/li>\n<li>Pass the cable end through the inner component and splay the armour wires over the cone.<\/li>\n<li>Tighten the outer component onto the inner component to the listed installation torque using a spanner.<\/li>\n<li>Insert the gland bush into the equipment cable entry, tighten the locknut, then slide the shroud over the gland.<\/li>\n<\/ol>\n<h2>Ordering Information<\/h2>\n<p>Provide the full BWC model code, cable and armour dimensions, thread form, required finish and quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC BWC Cable Glands provide mechanical retention for armoured cable in dry indoor installations. The catalogue lists 13 models from VO-BWC001 to VO-BWC013, with metric and NPT entry thread references.<\/p>\n<ul>\n<li>Brass construction, with a nickel-plated option.<\/li>\n<li>IP2X ingress protection stated without a shroud.<\/li>\n<li>Model-specific cable, armour, hexagon and installation torque values are listed below.<\/li>\n<\/ul>","protected":false},"featured_media":952,"template":"","meta":[],"product_brand":[],"product_cat":[89],"product_tag":[],"class_list":["post-954","product","type-product","status-publish","has-post-thumbnail","product_cat-armored-hazardous-area-glands","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/product\/954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/media\/952"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/media?parent=954"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/product_brand?post=954"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/product_cat?post=954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/ar\/wp-json\/wp\/v2\/product_tag?post=954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}