{"id":3116,"date":"2026-10-09T13:51:19","date_gmt":"2026-10-09T13:51:19","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=02edd22b5e64bbd7b7ae02e5d0bc4df93c3ed6071dad57c602e04a3158111c25"},"modified":"2026-10-09T13:51:19","modified_gmt":"2026-10-09T13:51:19","slug":"ts35-din-rail-dimensions","status":"publish","type":"post","link":"https:\/\/yocl.com\/de\/ts35-din-rail-dimensions\/","title":{"rendered":"TS35 DIN Schienenabmessungen: 35 \u00d7 7.5 vs 35 \u00d7 15"},"content":{"rendered":"<p><strong>Eine TS35 Hutschiene hat eine Nenn-DIN Profilbreite. Die hier verglichenen zwei Gr\u00f6\u00dfen haben Nenn-35 mm Profilh\u00f6hen von 7.5 mm und 15 mm. Profilh\u00f6he, Materialst\u00e4rke und Befestigungsschlitzabmessungen beschreiben unterschiedliche Merkmale; eine vollst\u00e4ndige Schienenspezifikation ben\u00f6tigt jede davon.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Nenn-Schienengr\u00f6\u00dfe<\/th>\n<th>Profilbreite<\/th>\n<th>Profilh\u00f6he\/-tiefe<\/th>\n<th>Was die Gr\u00f6\u00dfe identifiziert<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>35 \u00d7 7.5 mm<\/td>\n<td>35 mm<\/td>\n<td>7.5 mm<\/td>\n<td>Das flachere TS35 Hutschiene-Profil<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 15 mm<\/td>\n<td>35 mm<\/td>\n<td>15 mm<\/td>\n<td>Das tiefere TS35 Hutschiene-Profil<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Diese Nennma\u00dfe werden in YOCL angegeben <a href=\"https:\/\/yocl.com\/de\/product\/35x7-5mm-slotted-steel-din-rail\/\">35 \u00d7 7.5 mm Stahlschiene<\/a> und <a href=\"https:\/\/yocl.com\/de\/product\/35x15mm-slotted-steel-din-rail\/\">35 \u00d7 15 mm Stahlschiene<\/a> Aufzeichnungen. Es handelt sich um eine Nachschlagetabelle f\u00fcr die Querschnittsgr\u00f6\u00dfe, nicht um eine Toleranzzeichnung oder eine Garantie daf\u00fcr, dass ein bestimmtes Ger\u00e4t f\u00fcr beide H\u00f6hen passt.<\/p>\n<h2>Querschnittsgr\u00f6\u00dfe separat von der Dicke lesen<\/h2>\n<p>In <strong>35 \u00d7 7.5 mm<\/strong>, the 7.5 mm number describes the formed profile height. It does not mean that the rail material is 7.5 mm thick. The same distinction applies to the 15 mm height of the deeper section.<\/p>\n<p>For example, YOCL&#8217;s standard-slot 35 \u00d7 7.5 mm steel configuration offers <strong>0.9, 1.0 or 1.2 mm nominal material thickness<\/strong>. Its 35 \u00d7 15 mm steel configuration specifies <strong>1.5 mm Nenndicke<\/strong>. Keep these values in separate fields when reading a quotation or preparing a drawing.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ts35-din-rail-dimensions-profile-dimensions.webp\" alt=\"Conceptual TS35 end profiles showing nominal 35 mm width, 7.5 mm and 15 mm heights, and material thickness t\"><figcaption>Conceptual end profiles, not to scale, distinguish nominal section width and height from material thickness t. They do not specify flange details, bends or dimensional tolerances.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>Dimension field<\/th>\n<th>Describes<\/th>\n<th>Example from the YOCL range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Profile width \u00d7 height<\/td>\n<td>The formed rail section presented to the device<\/td>\n<td>35 \u00d7 7.5 mm or 35 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>Nennmaterialst\u00e4rke<\/td>\n<td>Thickness of the selected rail material<\/td>\n<td>1.0 mm standard-slot steel; 1.5 mm deep-profile steel<\/td>\n<\/tr>\n<tr>\n<td>Schlitzbreite \u00d7 L\u00e4nge<\/td>\n<td>One elongated fixing opening<\/td>\n<td>6.2 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>Slot pitch or hole layout<\/td>\n<td>Positions of successive fixing openings<\/td>\n<td>Obtain the selected configuration drawing<\/td>\n<\/tr>\n<tr>\n<td>Supplied rail length<\/td>\n<td>Length of the rail before any project-specific cutting<\/td>\n<td>1 m = 1,000 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A product description containing only \u201c35 mm DIN rail\u201d leaves the height, thickness, openings and length unresolved. It also leaves the detailed flange geometry and dimensional tolerances to the relevant drawing.<\/p>\n<h2>YOCL TS35 Thickness, Slot and Length Chart<\/h2>\n<p>Use the following chart as a <strong>YOCL product-configuration lookup<\/strong>, not as a universal table for every TS35 rail. All profile, thickness and slot values are in millimetres; supplied lengths are in metres.<\/p>\n<table>\n<thead>\n<tr>\n<th>Profil<\/th>\n<th>Material and configuration<\/th>\n<th>Nenndicke (mm)<\/th>\n<th>Schlitzbreite \u00d7 L\u00e4nge (mm)<\/th>\n<th>Supplied lengths (m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Steel, standard slots<\/td>\n<td>0.9 \/ 1.0 \/ 1.2<\/td>\n<td>6.2 \u00d7 15<\/td>\n<td>0.5 \/ 1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Steel, long slots<\/td>\n<td>0.9 \/ 1.0 \/ 1.2<\/td>\n<td>5.2 \u00d7 25<\/td>\n<td>0.5 \/ 1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Steel, blue-white appearance<\/td>\n<td>1.0<\/td>\n<td>6.2 \u00d7 15<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Steel, conventional 1.0 mm section<\/td>\n<td>1.0<\/td>\n<td>6.2 \u00d7 15<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Steel, ribbed section<\/td>\n<td>0.8<\/td>\n<td>5.2 \u00d7 15<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 15<\/td>\n<td>Steel, slotted<\/td>\n<td>1.5<\/td>\n<td>6.2 \u00d7 15<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Aluminium, smaller slots<\/td>\n<td>0.7 \/ 0.9 \/ 1.1<\/td>\n<td>4.2 \u00d7 12<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr>\n<td>35 \u00d7 7.5<\/td>\n<td>Aluminium, longer slots<\/td>\n<td>1.1<\/td>\n<td>4.8 \u00d7 25<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Sources: YOCL&#8217;s <a href=\"https:\/\/yocl.com\/de\/product\/35x7-5mm-slotted-steel-din-rail\/\">35 \u00d7 7.5 mm slotted steel configuration table<\/a>, <a href=\"https:\/\/yocl.com\/de\/product\/35x15mm-slotted-steel-din-rail\/\">35 \u00d7 15 mm slotted steel specifications<\/a> und <a href=\"https:\/\/yocl.com\/de\/product\/35x7-5mm-slotted-aluminium-din-rail\/\">35 \u00d7 7.5 mm slotted aluminium configuration table<\/a>, checked October 9, 2026. Each slash-separated entry is a listed choice within that row. Keep the selected configuration, thickness, slot size and length together.<\/p>\n<p>Two details are easy to miss:<\/p>\n<ul>\n<li><strong>A thickness does not uniquely identify the slot pattern.<\/strong> The 1.1 mm aluminium rail is listed with either 4.2 \u00d7 12 mm or 4.8 \u00d7 25 mm openings.<\/li>\n<li><strong>Length choices vary by configuration.<\/strong> The steel standard-slot and long-slot rows list 0.5 m lengths; the blue-white, conventional and ribbed rows list 1 m and 2 m.<\/li>\n<\/ul>\n<p>\u201cBlue-white\u201d identifies the catalogue appearance option. The label does not supply a coating thickness or corrosion classification. The ribbed row likewise supplies dimensions, not an independently verified load rating.<\/p>\n<h2>Slot Length Is Not Fixing Pitch<\/h2>\n<p>F\u00fcr eine <strong>6.2 \u00d7 15 mm slot<\/strong>, 6.2 mm is the opening width and 15 mm is the opening length. Those values do not state the distance between successive openings.<\/p>\n<p>The deeper steel rail illustrates the distinction particularly clearly: <strong>15 mm profile height<\/strong> und <strong>15 mm slot length<\/strong> appear in the same specification, but they describe different features.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ts35-din-rail-dimensions-slot-size-and-pitch.webp\" alt=\"Conceptual fixing openings showing 6.2 by 15 mm and 5.2 by 25 mm slot sizes, with centre-to-centre pitch P identified separately\"><figcaption>Slot width and length describe one opening; pitch P describes centre-to-centre spacing. This layout is conceptual and not to scale: obtain the selected rail drawing for the actual hole layout.<\/figcaption><\/figure>\n<p>When matching a rail to an existing backplate drawing, obtain the hole-layout information separately. Slot dimensions alone do not establish:<\/p>\n<ul>\n<li>spacing between openings;<\/li>\n<li>the position of the first opening relative to a rail end;<\/li>\n<li>where a project-specific cut falls relative to the slot pattern;<\/li>\n<li>the specified fastener, head clearance or receiving arrangement.<\/li>\n<\/ul>\n<p>A longer opening can provide more positioning allowance along the slot, but its width and the rest of the fixing arrangement still need to match. A 5.2 \u00d7 25 mm opening should therefore not be treated as an enlarged version of a 6.2 \u00d7 15 mm opening in every direction.<\/p>\n<h2>Does a Device Accept Both TS35 Heights?<\/h2>\n<p><strong>Check the device&#8217;s mounting specification rather than deciding from the shared 35 mm width.<\/strong> YOCL\u2019s <a href=\"https:\/\/yocl.com\/de\/product\/sj-terminal-blocks\/\">SJ cage-spring terminal-block record<\/a> explicitly lists <strong>TH35-7.5 oder TH35-15<\/strong>. That declaration applies to the stated SJ range; it does not establish two-height acceptance for every rail-mounted device.<\/p>\n<p>TS35 appears in these rail descriptions, while TH35 appears in the SJ mounting declaration. Match the complete section designation and drawing when checking either label.<\/p>\n<p>For a device documented for both heights, review its installed outline and access requirements against the panel layout. The nominal profile-height difference is <strong>15 \u2212 7.5 = 7.5 mm<\/strong>. That arithmetic does not by itself establish the change in every terminal, release point or device surface: use the actual assembly drawing.<\/p>\n<p><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29026\" target=\"_blank\" rel=\"noopener\">IEC 60715:2017<\/a> covers dimensions and functions relevant to compatible mechanical rail mounting. Its public catalogue scope does not supply the full dimensional tolerance drawings. The charts here use YOCL&#8217;s nominal product values and do not assert IEC conformity or working-load capacity.<\/p>\n<p>For orientation across top-hat, G-profile and mini rails, use <a href=\"https:\/\/yocl.com\/de\/din-rails-explained\/\">DIN Schienen erkl\u00e4rt: Profile, Montage und Zubeh\u00f6rpassform<\/a>.<\/p>\n<h2>TS35 Dimensions in Inches<\/h2>\n<p>Use <strong>inches = millimetres \u00f7 25.4<\/strong>. The international inch is exactly 25.4 mm, as documented by <a href=\"https:\/\/www.nist.gov\/pml\/owm\/si-units-length\" target=\"_blank\" rel=\"noopener\">NIST&#8217;s length-unit reference<\/a>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Nominal metric dimension<\/th>\n<th>Calculated inch equivalent, rounded to 3 decimal places<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>35 mm width<\/td>\n<td>1.378 in<\/td>\n<\/tr>\n<tr>\n<td>7.5 mm profile height<\/td>\n<td>0.295 in<\/td>\n<\/tr>\n<tr>\n<td>15 mm profile height<\/td>\n<td>0.591 in<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These are rounded conversions of nominal dimensions, not manufacturing tolerances. Retain the original metric dimensions when identifying the profile and use the specified drawing units for a fit check.<\/p>\n<h2>Worked Example: Specify the Aluminium Slot Variant<\/h2>\n<p>Suppose a bill of materials requests <strong>35 \u00d7 7.5 mm aluminium DIN rail, 1.1 mm thick, 2 m long<\/strong>. That description still matches two rows in the YOCL chart because both slot patterns are listed at 1.1 mm thickness.<\/p>\n<p>If the required opening is 4.2 \u00d7 12 mm, a more precise dimensional enquiry is:<\/p>\n<blockquote>\n<p>TS35 top-hat aluminium DIN rail; 35 \u00d7 7.5 mm profile; 1.1 mm nominal thickness; 4.2 \u00d7 12 mm fixing slots; 2,000 mm supplied length. Quantity: specify separately. Provide the required fixing layout and the device mounting reference for confirmation.<\/p>\n<\/blockquote>\n<p>The values identify one listed configuration. They do not approve its fasteners, support spacing or device fit. Those remaining checks need the project drawing and relevant mounting documentation.<\/p>\n<p>Verwenden Sie die <a href=\"https:\/\/yocl.com\/de\/din-rails-manufacturer\/\">YOCL DIN rail range<\/a> to route that description to the corresponding product record. Include any drawing revision and dimensional tolerances required by the project instead of assuming that the nominal size chart supplies them.<\/p>\n<h2>Referenzen<\/h2>\n<ul>\n<li>YOCL ELECTRIC \u2014 <a href=\"https:\/\/yocl.com\/de\/product\/35x7-5mm-slotted-steel-din-rail\/\">35 \u00d7 7.5 mm geschlitzter Stahl DIN Schiene<\/a>; first-party nominal section, thickness, slot and length configuration data.<\/li>\n<li>YOCL ELECTRIC \u2014 <a href=\"https:\/\/yocl.com\/de\/product\/35x15mm-slotted-steel-din-rail\/\">35 \u00d7 15 mm geschlitzter Stahl DIN Schiene<\/a>; first-party nominal section and fixing-opening specifications.<\/li>\n<li>YOCL ELECTRIC \u2014 <a href=\"https:\/\/yocl.com\/de\/product\/35x7-5mm-slotted-aluminium-din-rail\/\">35 \u00d7 7.5 mm geschlitztes Aluminium DIN Schiene<\/a>; first-party thickness-and-slot pairings and supplied lengths.<\/li>\n<li>YOCL ELECTRIC \u2014 <a href=\"https:\/\/yocl.com\/de\/product\/sj-terminal-blocks\/\">SJ K\u00e4figklemmen DIN Reiheneinbauklemmen<\/a>; erstseitige TH35-7.5 \/ TH35-15 Montageerkl\u00e4rung.<\/li>\n<li>IEC \u2014 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29026\" target=\"_blank\" rel=\"noopener\">IEC 60715:2017<\/a>, edition 2.0; public catalogue scope for compatible mechanical rail mounting. Full standard not consulted.<\/li>\n<li>NIST \u2014 <a href=\"https:\/\/www.nist.gov\/pml\/owm\/si-units-length\" target=\"_blank\" rel=\"noopener\">SI Units \u2014 Length<\/a>; exact international-inch conversion.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>A TS35 top-hat DIN rail has a nominal 35 mm profile width. The two sizes compared here have nominal profile heights of 7.5 mm and 15 mm. Profile height, material thickness and fixing-slot dimensions describe different features; a complete rail specification needs each of them. Nominal rail size Profile width Profile height\/depth What the size [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3115,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[173],"tags":[],"class_list":["post-3116","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-din-rails-wiring-tools"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/posts\/3116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/comments?post=3116"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/posts\/3116\/revisions"}],"predecessor-version":[{"id":3117,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/posts\/3116\/revisions\/3117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/3115"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=3116"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/categories?post=3116"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/tags?post=3116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}