{"id":1452,"date":"2026-10-01T09:53:01","date_gmt":"2026-10-01T09:53:01","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1452"},"modified":"2026-10-01T09:53:08","modified_gmt":"2026-10-01T09:53:08","slug":"jt-ladder-self-locking-stainless-steel-cable-ties","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/jt-ladder-self-locking-stainless-steel-cable-ties\/","title":{"rendered":"JT Ladder Self-Locking Stainless Steel Cable Ties"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>The YOCL ELECTRIC JT Ladder Self-Locking Stainless Steel Cable Ties use a ladder-style band with multiple-hook locking. The supplied dimension table covers uncoated JT and coated JTP versions in 7 mm and 12 mm widths.<\/p>\n<p>The locking system avoids additional rolling and folding of the band. An enlarged slot at the tail supports use with a hook-type installation tool. Listed stainless steel grades are 201, 304 and 316.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Self-locking ladder band:<\/strong> Multiple-hook construction for securing bundles.<\/li>\n<li><strong>Tool access:<\/strong> Enlarged tail slot for a hook-type tool.<\/li>\n<li><strong>Finish choices:<\/strong> Uncoated metal and coated versions.<\/li>\n<li><strong>Width-specific strength:<\/strong> 667 N minimum tensile strength at 7 mm width and 1,000 N at 12 mm width.<\/li>\n<li><strong>Coated band protection:<\/strong> A coating provides an additional barrier at band edges and between the metal band and bundled materials.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Dimensioned series<\/td>\n<td>JT uncoated; JTP coated<\/td>\n<\/tr>\n<tr>\n<td>Locking construction<\/td>\n<td>Ladder-style band, multiple hooks<\/td>\n<\/tr>\n<tr>\n<td>Stainless steel grades listed<\/td>\n<td>201; 304; 316<\/td>\n<\/tr>\n<tr>\n<td>Width options<\/td>\n<td>7 mm; 12 mm<\/td>\n<\/tr>\n<tr>\n<td>Thickness options listed<\/td>\n<td>0.25 mm; 0.30 mm<\/td>\n<\/tr>\n<tr>\n<td>Lengths listed<\/td>\n<td>150; 225; 300; 400; 450; 550; 600; 700 mm<\/td>\n<\/tr>\n<tr>\n<td>Minimum tensile strength, 7 mm width<\/td>\n<td>667 N \/ 150 lbf<\/td>\n<\/tr>\n<tr>\n<td>Minimum tensile strength, 12 mm width<\/td>\n<td>1,000 N \/ 225 lbf<\/td>\n<\/tr>\n<tr>\n<td>Coating materials listed in the source<\/td>\n<td>Polyester; epoxy; nylon 11<\/td>\n<\/tr>\n<tr>\n<td>Recommended installation tools<\/td>\n<td>CT02; HT-338<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The source does not assign individual coating materials, steel grades or thicknesses to specific order codes. Select these details for the required supplied configuration.<\/p>\n<h2>Dimension<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/jt-ladder-self-locking-stainless-steel-cable-ties-dimension.webp\" alt=\"JT Ladder Self-Locking Stainless Steel Cable Ties dimension drawing\"><\/p>\n<p>The table uses the source&#8217;s explicit length column. Some printed item numbers contain a different length suffix, so they are not used as order codes here. Inch values are rounded conversions from millimetres.<\/p>\n<table>\n<thead>\n<tr>\n<th>Width W (mm)<\/th>\n<th>Length L (mm)<\/th>\n<th>Width (inch)<\/th>\n<th>Length (inch)<\/th>\n<th>Minimum tensile strength (N)<\/th>\n<th>Minimum tensile strength (lbf)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>7<\/td>\n<td>150<\/td>\n<td>0.28<\/td>\n<td>5.9<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>225<\/td>\n<td>0.28<\/td>\n<td>8.9<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>300<\/td>\n<td>0.28<\/td>\n<td>11.8<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>400<\/td>\n<td>0.28<\/td>\n<td>15.7<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>450<\/td>\n<td>0.28<\/td>\n<td>17.7<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>550<\/td>\n<td>0.28<\/td>\n<td>21.7<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>600<\/td>\n<td>0.28<\/td>\n<td>23.6<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>700<\/td>\n<td>0.28<\/td>\n<td>27.6<\/td>\n<td>667<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>150<\/td>\n<td>0.47<\/td>\n<td>5.9<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>225<\/td>\n<td>0.47<\/td>\n<td>8.9<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>300<\/td>\n<td>0.47<\/td>\n<td>11.8<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>400<\/td>\n<td>0.47<\/td>\n<td>15.7<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>450<\/td>\n<td>0.47<\/td>\n<td>17.7<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>550<\/td>\n<td>0.47<\/td>\n<td>21.7<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>600<\/td>\n<td>0.47<\/td>\n<td>23.6<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>700<\/td>\n<td>0.47<\/td>\n<td>27.6<\/td>\n<td>1,000<\/td>\n<td>225<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Listed band thicknesses are 0.25 mm (approximately 0.010 inch) and 0.30 mm (approximately 0.012 inch). Overall bundle diameter D is illustrated but no numerical range is supplied.<\/p>\n<h2>Related Single-Hook Series<\/h2>\n<p>The supplied page also identifies JTE and JTEP as single-hook versions. It does not provide a separate dimension or tensile-strength table for those series; the JT\/JTP values above are not assigned to them.<\/p>\n<h2>Temperature and Finish Selection<\/h2>\n<p>The source gives \u221280 \u00b0C to +538 \u00b0C under the multiple-hook JT\/JTP heading and \u221280 \u00b0C to +150 \u00b0C under the single-hook JTE\/JTEP heading. It does not separate the temperature rating of each bare-metal or coated configuration. A +538 \u00b0C rating is therefore not assigned to every coated version in this product data.<\/p>\n<p>Specify the required working temperature and coating when selecting the supplied configuration.<\/p>\n<h2>Ordering Information<\/h2>\n<p>Specify JT or JTP, band width, actual length, thickness, stainless steel grade and required finish. For coated versions, specify the coating material and working temperature. Select CT02 or HT-338 tooling as appropriate for the supplied band configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>JT ladder self-locking stainless steel cable ties with multiple-hook locking, available as uncoated JT or coated JTP versions.<\/p>\n<ul>\n<li>Listed stainless steel grades: 201, 304 and 316.<\/li>\n<li>Widths: 7 mm and 12 mm; listed lengths: 150\u2013700 mm.<\/li>\n<li>Minimum tensile strength: 667 N for 7 mm; 1,000 N for 12 mm.<\/li>\n<li>Listed thickness options: 0.25 mm and 0.30 mm.<\/li>\n<li>Recommended tools: CT02 and HT-338.<\/li>\n<\/ul>","protected":false},"featured_media":1449,"template":"","meta":[],"product_brand":[],"product_cat":[41],"product_tag":[],"class_list":["post-1452","product","type-product","status-publish","has-post-thumbnail","product_cat-stainless-steel-cable-ties","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/1452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/1449"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=1452"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=1452"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=1452"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=1452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}