{"id":2001,"date":"2026-10-04T04:57:50","date_gmt":"2026-10-04T04:57:50","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2001"},"modified":"2026-10-04T04:57:57","modified_gmt":"2026-10-04T04:57:57","slug":"tb-terminal-blocks","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/tb-terminal-blocks\/","title":{"rendered":"TB Serie Platten-Schraubklemmen"},"content":{"rendered":"<h2>\u00dcbersicht<\/h2>\n<p>YOCL ELECTRIC TB Series Plate-Screw Terminal Blocks connect conductors in industrial control and distribution systems. The closed, integrated construction uses plate-type screw clamping with OT and UT terminals. The listed TB and TBC models are rated 600 V, with individual current ratings from 15 A to 100 A.<\/p>\n<h2>Merkmale<\/h2>\n<ul>\n<li>Plate-type screw clamping for OT and UT terminals.<\/li>\n<li>Protective dust covers and clear PVC markings.<\/li>\n<li>Five model-specific current groups.<\/li>\n<li>Baseplate mounting provisions for panel installation.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marke<\/td>\n<td>YOCL ELEKTRO<\/td>\n<\/tr>\n<tr>\n<td>Serie<\/td>\n<td>TB \/ TBC<\/td>\n<\/tr>\n<tr>\n<td>Verbindung<\/td>\n<td>Plate-type screw clamping<\/td>\n<\/tr>\n<tr>\n<td>Konstruktion<\/td>\n<td>Closed, integrated structure<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage<\/td>\n<td>600 V<\/td>\n<\/tr>\n<tr>\n<td>Current ratings<\/td>\n<td>15, 25, 45, 60 and 100 A, depending on model<\/td>\n<\/tr>\n<tr>\n<td>Listed conductor ranges<\/td>\n<td>Model-dependent; see table<\/td>\n<\/tr>\n<tr>\n<td>Terminal compatibility<\/td>\n<td>OT \/ UT<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Model Specifications<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Rated current<\/th>\n<th>Listed poles<\/th>\n<th>Conductor range<\/th>\n<th>Mounting size L1<\/th>\n<th>Outline dimensions L \u00d7 W \u00d7 H<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>TB-1503<\/td>\n<td>15 A<\/td>\n<td>3<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>34 mm<\/td>\n<td>45.3 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-1504<\/td>\n<td>15 A<\/td>\n<td>4<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>44 mm<\/td>\n<td>54.3 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-1505<\/td>\n<td>15 A<\/td>\n<td>5<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>57 mm<\/td>\n<td>63.3 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-1506<\/td>\n<td>15 A<\/td>\n<td>6<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>61 mm<\/td>\n<td>72 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-1510<\/td>\n<td>15 A<\/td>\n<td>10<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>96 mm<\/td>\n<td>108 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-1512<\/td>\n<td>15 A<\/td>\n<td>12<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>114 mm<\/td>\n<td>125 \u00d7 22 \u00d7 15 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2503<\/td>\n<td>25 A<\/td>\n<td>3<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>44 mm<\/td>\n<td>55 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2504<\/td>\n<td>25 A<\/td>\n<td>4<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>57 mm<\/td>\n<td>67 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2505<\/td>\n<td>25 A<\/td>\n<td>5<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>\u2014<\/td>\n<td>80 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2506<\/td>\n<td>25 A<\/td>\n<td>6<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>81 mm<\/td>\n<td>91 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2510<\/td>\n<td>25 A<\/td>\n<td>10<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>129 mm<\/td>\n<td>139 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-2512<\/td>\n<td>25 A<\/td>\n<td>10<\/td>\n<td>0.5\u20132.5 mm\u00b2<\/td>\n<td>154 mm<\/td>\n<td>164.5 \u00d7 30 \u00d7 17 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4503<\/td>\n<td>45 A<\/td>\n<td>3<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>58.5 mm<\/td>\n<td>69.5 \u00d7 68 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4504<\/td>\n<td>45 A<\/td>\n<td>4<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>75 mm<\/td>\n<td>86 \u00d7 38 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4505<\/td>\n<td>45 A<\/td>\n<td>5<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>91.5 mm<\/td>\n<td>102.5 \u00d7 38 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4506<\/td>\n<td>45 A<\/td>\n<td>6<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>108 mm<\/td>\n<td>119 \u00d7 38 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4510<\/td>\n<td>45 A<\/td>\n<td>10<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>174 mm<\/td>\n<td>185 \u00d7 38 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TB-4512<\/td>\n<td>45 A<\/td>\n<td>12<\/td>\n<td>1.5\u20134 mm\u00b2<\/td>\n<td>207 mm<\/td>\n<td>218 \u00d7 38 \u00d7 21 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-603<\/td>\n<td>60 A<\/td>\n<td>3<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>60.5 mm<\/td>\n<td>84.5 \u00d7 54.5 \u00d7 31.5 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-604<\/td>\n<td>60 A<\/td>\n<td>4<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>82.5 mm<\/td>\n<td>113 \u00d7 54.5 \u00d7 31.5 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-605<\/td>\n<td>60 A<\/td>\n<td>6<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>118 mm<\/td>\n<td>129 \u00d7 54.5 \u00d7 31.5 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-1003<\/td>\n<td>100 A<\/td>\n<td>3<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>75.5 mm<\/td>\n<td>86.5 \u00d7 43.5 \u00d7 35 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-1004<\/td>\n<td>100 A<\/td>\n<td>4<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>96 mm<\/td>\n<td>108 \u00d7 43.5 \u00d7 35 mm<\/td>\n<\/tr>\n<tr>\n<td>TBC-1006<\/td>\n<td>100 A<\/td>\n<td>6<\/td>\n<td>2.5\u20136 mm\u00b2<\/td>\n<td>140 mm<\/td>\n<td>153 \u00d7 43.5 \u00d7 35 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A dash indicates that the mounting value is not specified.<\/p>\n<h2>Auswahlhilfe<\/h2>\n<ul>\n<li>Match the selected model&#8217;s current rating, conductor range and pole count to the circuit.<\/li>\n<li>Check L1 and outline dimensions against the available panel space.<\/li>\n<li>Specify the required OT or UT termination arrangement when ordering.<\/li>\n<\/ul>\n<h2>Anwendungen<\/h2>\n<ul>\n<li>Industrial control panels and machinery.<\/li>\n<li>Power distribution systems.<\/li>\n<li>Motor control centres.<\/li>\n<li>HVAC and building automation.<\/li>\n<\/ul>\n<h2>Bestellinformationen<\/h2>\n<p>Specify <strong>YOCL ELEKTRO<\/strong>, the <strong>TB or TBC model<\/strong>, circuit requirements, terminal arrangement, mounting constraints and quantity.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC TB Series Plate-Screw Terminal Blocks provide wire termination for industrial control and power distribution systems.<\/p>\n<ul>\n<li><strong>24 TB and TBC models<\/strong>, rated <strong>600 V<\/strong>.<\/li>\n<li>Model-specific current ratings: <strong>15 A, 25 A, 45 A, 60 A and 100 A<\/strong>.<\/li>\n<li>Listed conductor ranges span <strong>0.5\u20136 mm\u00b2<\/strong>, depending on model.<\/li>\n<li><strong>Plate-type screw clamping<\/strong> for <strong>OT and UT terminals<\/strong>.<\/li>\n<li>Closed construction, protective dust covers and clear PVC markings.<\/li>\n<\/ul>","protected":false},"featured_media":2000,"template":"","meta":[],"product_brand":[],"product_cat":[22],"product_tag":[],"class_list":["post-2001","product","type-product","status-publish","has-post-thumbnail","product_cat-terminal-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/2001","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/2000"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=2001"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=2001"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=2001"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=2001"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}