{"id":2844,"date":"2026-10-07T13:14:30","date_gmt":"2026-10-07T13:14:30","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2844"},"modified":"2026-10-07T13:14:38","modified_gmt":"2026-10-07T13:14:38","slug":"ip44-angled-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/ip44-angled-panel-sockets\/","title":{"rendered":"IP44 Winkel-Einbaubuchsen"},"content":{"rendered":"<h2>\u00dcbersicht<\/h2>\n<p>YOCL ELEKTRO IP44 abgewinkelte Einbaubuchsen bieten einen festen Buchsenanschluss f\u00fcr kompatible Industriestecker. Die Serie umfasst 16 \/ 32 A Nennstr\u00f6me und 2P+E, 3P+E, 3P+N+E Kontaktbelegungen. Jedes Modell kombiniert eine spezifische Stromst\u00e4rke, Spannung, Erdungsposition und Geh\u00e4usedesign.<\/p>\n<p>Die Auswahltabellen fassen die verf\u00fcgbaren Geh\u00e4useversionen in einer Produktfamilie zusammen. Verwenden Sie den vollst\u00e4ndigen NM-Modellcode, um die elektrische Konfiguration und die entsprechenden Einbauma\u00dfe anzugeben.<\/p>\n<h2>Merkmale<\/h2>\n<ul>\n<li>Abgewinkelter Steckdoseneinsatz und Montageflansch f\u00fcr eine Schalttafeleinbau.<\/li>\n<li>IP44 Schutzart f\u00fcr die aufgef\u00fchrten Modelle.<\/li>\n<li>Klappdeckel an der Steckdosenfront.<\/li>\n<li>Blaue und rote Konfigurationen, aufgef\u00fchrt nach exaktem Modell in den Auswahltabellen.<\/li>\n<li>Modellspezifische Leiterbereiche und Einbauma\u00dfe f\u00fcr die Auswahl des elektrischen Anschlusses und des Installationsraums.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marke<\/td>\n<td>YOCL ELEKTRO<\/td>\n<\/tr>\n<tr>\n<td>Produkttyp<\/td>\n<td>IP44 Winkel-Einbaubuchsen<\/td>\n<\/tr>\n<tr>\n<td>Kontaktgender<\/td>\n<td>Buchse<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Winkel-Panelmontage<\/td>\n<\/tr>\n<tr>\n<td>Schutzart<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Nennstromoptionen<\/td>\n<td>16 \/ 32 A<\/td>\n<\/tr>\n<tr>\n<td>Kontaktbelegungen<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Spannungskonfigurationen<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Erdungskontaktpositionen<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Leiterquerschnitt<\/td>\n<td>Modellspezifische Werte in den Auswahltabellen<\/td>\n<\/tr>\n<tr>\n<td>Geh\u00e4usevarianten<\/td>\n<td>H housing, 16\/32 A; Standard housing, 16\/32 A<\/td>\n<\/tr>\n<tr>\n<td>Modelloptionen<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Modellauswahltabellen<\/h2>\n<p>Spannungs- und Stromwerte geh\u00f6ren zur exakten Modellzeile. Ein Bindestrich bedeutet, dass kein modellspezifischer Wert in den gelieferten Daten verf\u00fcgbar ist.<\/p>\n<h3>H-Geh\u00e4use, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413H<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-423H<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-414H<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-424H<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-415H<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-425H<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-423<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-414<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-424<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-415<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-425<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Abmessung<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>H-Geh\u00e4use, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413H<\/td>\n<td>64<\/td>\n<td>75<\/td>\n<td>52<\/td>\n<td>60<\/td>\n<td>50<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>NM-423H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-414H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-424H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-415H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-425H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing holes \u00d85.<\/p>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413<\/td>\n<td>62<\/td>\n<td>68<\/td>\n<td>47<\/td>\n<td>48<\/td>\n<td>36<\/td>\n<td>37<\/td>\n<td>55<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>NM-423<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>43<\/td>\n<td>75<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<td>NM-414<\/td>\n<td>76<\/td>\n<td>86<\/td>\n<td>62<\/td>\n<td>62<\/td>\n<td>47<\/td>\n<td>37<\/td>\n<td>64<\/td>\n<td>57<\/td>\n<\/tr>\n<tr>\n<td>NM-424<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>43<\/td>\n<td>75<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<td>NM-415<\/td>\n<td>76<\/td>\n<td>86<\/td>\n<td>62<\/td>\n<td>62<\/td>\n<td>47<\/td>\n<td>37<\/td>\n<td>72<\/td>\n<td>65<\/td>\n<\/tr>\n<tr>\n<td>NM-425<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>47<\/td>\n<td>81<\/td>\n<td>70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing holes \u00d85.<\/p>\n<h2>Auswahlhilfe<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Bestellinformationen<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTRO IP44 abgewinkelte Einbaubuchsen f\u00fcr feste industrielle Stromanschl\u00fcsse.<\/p>\n<ul>\n<li>Strombelastbarkeit: 16 \/ 32 A.<\/li>\n<li>Kontaktbelegung: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Buchse mit Klappdeckel und Einbauflansch.<\/li>\n<li>Vollst\u00e4ndige Modellauswahltabellen enthalten Spannung, Position des Schutzkontakts, Leiterquerschnitte und geh\u00e4usespezifische Abmessungen.<\/li>\n<li>Auswahl und Anfrage \u00fcber vollst\u00e4ndigen NM-Modellcode.<\/li>\n<\/ul>","protected":false},"featured_media":2843,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2844","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/2844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/2843"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=2844"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=2844"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=2844"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=2844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}