{"id":2846,"date":"2026-10-07T13:33:13","date_gmt":"2026-10-07T13:33:13","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2846"},"modified":"2026-10-07T13:35:45","modified_gmt":"2026-10-07T13:35:45","slug":"ip44-industrial-appliance-inlets","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/ip44-industrial-appliance-inlets\/","title":{"rendered":"IP44 Industrielle Ger\u00e4teeinl\u00e4sse"},"content":{"rendered":"<h2>\u00dcbersicht<\/h2>\n<p>YOCL ELEKTRO IP44 Industriesteckverbinder bieten einen m\u00e4nnlichen Stromanschluss an Maschinen, Verteilern und Ger\u00e4tegeh\u00e4usen. Die Familie umfasst 16 A und 32 A Ausf\u00fchrungen in 2P+E, 3P+E und 3P+N+E Konfigurationen. Gerade Frontplattensteckverbinder und geschlossene Aufputz-Steckverbinderdesigns sind hier gruppiert, sodass die Versorgungsschnittstelle zusammen mit ihrer Montageart ausgew\u00e4hlt werden kann. Ein passender weiblicher Kabelsteckverbinder bietet den abnehmbaren Kabelanschluss.<\/p>\n<h2>Merkmale<\/h2>\n<ul>\n<li>IP44 Ausf\u00fchrungen f\u00fcr spritzwassergesch\u00fctzte industrielle Anschl\u00fcsse.<\/li>\n<li>Gerade Frontplatten-Designs in Standard- und K-Geh\u00e4usen sowie Aufputz-Designs mit abgewinkeltem Steckgesicht.<\/li>\n<li>16 A und 32 A Auswahlm\u00f6glichkeiten mit Angabe der Leiterbereiche f\u00fcr jedes Modell.<\/li>\n<li>6h Erdungsposition bei den aufgef\u00fchrten Modellen.<\/li>\n<li>Blaue und rote Geh\u00e4usefarben unterscheiden die aufgef\u00fchrten elektrischen Konfigurationen.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marke<\/td>\n<td>YOCL ELEKTRO<\/td>\n<\/tr>\n<tr>\n<td>Produkttyp<\/td>\n<td>Industriesteckverbinder \/ Ger\u00e4testeckereingang<\/td>\n<\/tr>\n<tr>\n<td>Schutzart<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Nennstromauswahl<\/td>\n<td>16 A, 32 A<\/td>\n<\/tr>\n<tr>\n<td>Kontaktbelegung<\/td>\n<td>2P+E; 3P+E; 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Erdungskontaktposition<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Einbau- oder Aufbaugeh\u00e4usemontage, je nach Modell<\/td>\n<\/tr>\n<tr>\n<td>Passende Kabelverbindung<\/td>\n<td>Passender Buchsen-Industriesteckverbinder<\/td>\n<\/tr>\n<tr>\n<td>Leiterkapazit\u00e4t<\/td>\n<td>Modellspezifisch; siehe Auswahltabelle<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Modellauswahl<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Montage \/ Geh\u00e4use<\/th>\n<th>Strom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung<\/th>\n<th>Erdungsposition<\/th>\n<th>Kontaktgeh\u00e4use<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>P denotes a phase contact, N neutral and E protective earth. A dash means that no voltage is assigned in this selection table.<\/p>\n<h2>Abmessung<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Lettered outline dimensions (mm)<\/th>\n<th>Fixed mounting geometry<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use the lettered dimensions with the matching inlet outline. Flange geometry and housing size differ between body versions; select the complete model code when checking installation space.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-02.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-03.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<h2>Anschlusswahl<\/h2>\n<p>Match rated current, contact configuration, voltage and earth-contact position at both sides of the connection. Select panel or surface mounting before comparing the housing dimensions. The IP rating applies to the correctly assembled connection with its compatible mating interface; maintain the specified sealing and closure arrangement.<\/p>\n<h2>Bestellinformationen<\/h2>\n<p>Send YOCL ELECTRIC the full model code, required quantity, supply voltage, contact configuration and installation arrangement. Include conductor cross-section and the mating cable connector when requesting a complete equipment power connection.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELEKTRO IP44 Industriesteckverbinder in 16 A und 32 A Ausf\u00fchrungen. W\u00e4hlen Sie 2P+E, 3P+E oder 3P+N+E Kontakte, Frontplatten- oder Aufputzmontage und die passende Leiterkapazit\u00e4t aus der Modelltabelle.<\/p>","protected":false},"featured_media":2845,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2846","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/2845"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=2846"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=2846"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}