{"id":2856,"date":"2026-10-07T13:58:16","date_gmt":"2026-10-07T13:58:16","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2856"},"modified":"2026-10-07T13:58:26","modified_gmt":"2026-10-07T13:58:26","slug":"ip44-industrial-cable-couplers","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/ip44-industrial-cable-couplers\/","title":{"rendered":"IP44 Industrielle Kabelkupplungen"},"content":{"rendered":"<h2>\u00dcbersicht<\/h2>\n<p>YOCL ELECTRIC IP44 Industrielle Kabelkupplungen sind Kabelsteckverbinder f\u00fcr industrielle Kabelverbindungen. Diese Familie vereint die tats\u00e4chlichen 16 A und 32 A Modelle, die unten aufgef\u00fchrt sind, mit 2P+E, 3P+E und 3P+N+E Kontaktbelegungen. Jedes Modell hat seine eigene Spannung, Erdungskontakt-Position und sein eigenes Geh\u00e4usedesign.<\/p>\n<p>Das Steckverbinderende hat Buchsenkontakte und eine sch\u00fctzende Frontabdeckung; der hintere Eingang nimmt das Versorgungskabel auf. H-Design, K-Design, wei\u00dfer hinterer K\u00f6rper und spezielle Uhrenpositionsversionen bleiben separate Modellgruppen, damit das Geh\u00e4usefoto und die Ma\u00dfdaten mit dem richtigen Steckverbinder \u00fcbereinstimmen.<\/p>\n<h2>Merkmale<\/h2>\n<ul>\n<li>IP44 Schutzart f\u00fcr die aufgef\u00fchrten Modelle.<\/li>\n<li>Buchsenkontakte und eine Schutzabdeckung f\u00fcr das Kabelsteckverbinderende.<\/li>\n<li>Nennstromoptionen: 16 A und 32 A; die tats\u00e4chlichen Kombinationen sind durch die Modelltabellen definiert.<\/li>\n<li>2P+E, 3P+E und 3P+N+E Versionen werden einzeln identifiziert.<\/li>\n<li>Schutzkontakt-Layouts: 4h, 6h und ausgew\u00e4hlte 9h, gem\u00e4\u00df dem genannten Modell.<\/li>\n<li>Separate Geh\u00e4usegruppen erhalten die Leiterkapazit\u00e4t und die Ma\u00dfdaten jedes Modells.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marke<\/td>\n<td>YOCL ELEKTRO<\/td>\n<\/tr>\n<tr>\n<td>Produkttyp<\/td>\n<td>Kabelsteckverbinder Buchse<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Kabelmontage<\/td>\n<\/tr>\n<tr>\n<td>Schutzart<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Bemessungsstr\u00f6me<\/td>\n<td>16 A und 32 A<\/td>\n<\/tr>\n<tr>\n<td>Kontaktbelegungen<\/td>\n<td>2P+E (3 Kontakte); 3P+E (4 Kontakte); 3P+N+E (5 Kontakte)<\/td>\n<\/tr>\n<tr>\n<td>Erdkontaktstellungen<\/td>\n<td>4h, 6h und ausgew\u00e4hlte 9h<\/td>\n<\/tr>\n<tr>\n<td>Spannungskonfigurationen<\/td>\n<td>Siehe die einzelnen Modellzeilen; gepaarte F\u00fcnf-Kontakt-Nennwerte bleiben wie angegeben erhalten.<\/td>\n<\/tr>\n<tr>\n<td>Leiterquerschnitte<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Geh\u00e4usedesign H \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Printed reference<\/th>\n<th>Strom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>514<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>526<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>NM5<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>NM6<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Geh\u00e4usedesign K \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Strom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Wei\u00dfe R\u00fcckseiten-Designs \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Strom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Gelb<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Spezielle 9h Kontaktanordnungen \u2014 16 \/ 32 A<\/h2>\n<p>These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Strom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213L-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-223L-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Rot<\/td>\n<\/tr>\n<tr>\n<td>NM-214L-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Blau<\/td>\n<\/tr>\n<tr>\n<td>NM-224L-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Blau<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Abmessung<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Geh\u00e4usedesign H \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>a = 156.5; b = 51.3; c = 61.2<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>a = 161.7; b = 50.2; c = 69<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>a = 200; b = 70.8; c = 79.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Geh\u00e4usedesign K \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>a = 143; b = 80; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>a = 150; b = 82; c = 64<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>a = 167; b = 97; c = 72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Wei\u00dfe R\u00fcckseiten-Designs \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>a = 131; b = 79; c = 56; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>a = 141; b = 93; c = 64; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>a = 154; b = 101; c = 71; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-02.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-03.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-04.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-05.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<h2>Auswahlhilfe<\/h2>\n<p>Choose a female cable coupler when the mating connection is made at the end of a cable. A wall-mounted socket or an appliance inlet belongs to a different mounting and contact family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Bestellinformationen<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP44 industrial cable couplers, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 Industrielle Kabelkupplungen f\u00fcr Kabelendverbindungen, mit unterschiedlichen Geh\u00e4usedesigns und vollst\u00e4ndigen NM-Modellauswahltabellen.<\/p>\n<ul>\n<li>Nennstr\u00f6me: 16 A und 32 A.<\/li>\n<li>Kontaktbelegungen: 2P+E, 3P+E und 3P+N+E.<\/li>\n<li>4h, 6h und ausgew\u00e4hlte 9h Schutzkontakt-Anordnungen, je nach Modell.<\/li>\n<li>Kabelsteckverbinder mit Frontabdeckung.<\/li>\n<li>Spannung, Leiterkapazit\u00e4t und Abmessungen anhand des vollst\u00e4ndigen Modellcodes ausw\u00e4hlen.<\/li>\n<\/ul>","protected":false},"featured_media":2850,"template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":["post-2856","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-couplers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/2856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/2850"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=2856"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=2856"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=2856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=2856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}