{"id":2897,"date":"2026-10-07T14:39:08","date_gmt":"2026-10-07T14:39:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2897"},"modified":"2026-10-07T14:39:17","modified_gmt":"2026-10-07T14:39:17","slug":"ip67-straight-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/de\/product\/ip67-straight-panel-sockets\/","title":{"rendered":"IP67 Gerade Einbaubuchsen f\u00fcr Schalttafeleinbau"},"content":{"rendered":"<h2>\u00dcbersicht<\/h2>\n<p>YOCL ELECTRIC IP67 gerade Einbaubuchsen bieten einen festen weiblichen Anschlusspunkt f\u00fcr kompatible Industriestecker. Die Serie umfasst 16 \/ 32 \/ 63 \/ 125 A Nennwerte und 2P+E, 3P+E, 3P+N+E Kontaktbelegungen. Jedes Modell kombiniert eine spezifische Stromst\u00e4rke, Spannung, Erdungsposition und Geh\u00e4usedesign.<\/p>\n<p>Die Auswahltabellen fassen die verf\u00fcgbaren Geh\u00e4useversionen in einer Produktfamilie zusammen. Verwenden Sie den vollst\u00e4ndigen NM-Modellcode, um die elektrische Konfiguration und die entsprechenden Einbauma\u00dfe anzugeben.<\/p>\n<h2>Merkmale<\/h2>\n<ul>\n<li>Gerade Buchsenachse und Montageflansch f\u00fcr eine Einbauinstallation.<\/li>\n<li>IP67 Schutzart f\u00fcr die aufgef\u00fchrten Modelle.<\/li>\n<li>Klappdeckel an der Steckdosenfront.<\/li>\n<li>Blaue und rote Konfigurationen, aufgef\u00fchrt nach exaktem Modell in den Auswahltabellen.<\/li>\n<li>Modellspezifische Leiterbereiche und Einbauma\u00dfe f\u00fcr die Auswahl des elektrischen Anschlusses und des Installationsraums.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spezifikation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marke<\/td>\n<td>YOCL ELEKTRO<\/td>\n<\/tr>\n<tr>\n<td>Produkttyp<\/td>\n<td>IP67 Gerade Einbaubuchsen f\u00fcr Schalttafeleinbau<\/td>\n<\/tr>\n<tr>\n<td>Kontaktgender<\/td>\n<td>Buchse<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Gerade Einbau-<\/td>\n<\/tr>\n<tr>\n<td>Schutzart<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Nennstromoptionen<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Kontaktbelegungen<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Spannungskonfigurationen<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Erdungskontaktpositionen<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Leiterquerschnitt<\/td>\n<td>Modellspezifische Werte in den Auswahltabellen<\/td>\n<\/tr>\n<tr>\n<td>Geh\u00e4usevarianten<\/td>\n<td>Ausf\u00fchrung 1 Geh\u00e4use, 16\/32 A; Ausf\u00fchrung 2 Geh\u00e4use, 63\/125 A; Ausf\u00fchrung 2 Geh\u00e4use, 16\/32 A; Standardgeh\u00e4use, 63\/125 A<\/td>\n<\/tr>\n<tr>\n<td>Modelloptionen<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Modellauswahltabellen<\/h2>\n<p>Spannungs- und Stromwerte geh\u00f6ren zur exakten Modellzeile. Ein Bindestrich bedeutet, dass kein modellspezifischer Wert in den gelieferten Daten verf\u00fcgbar ist.<\/p>\n<h3>Ausf\u00fchrung 1 Geh\u00e4use, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>Nennstrom (A)<\/th>\n<th>Kontakte<\/th>\n<th>Spannung (V)<\/th>\n<th>Erdungsposition<\/th>\n<th>Farbe<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Blau<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Rot<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Abmessung<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Ausf\u00fchrung 1 Geh\u00e4use, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a, b (mm)<\/th>\n<th>c, d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>56<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>56<\/td>\n<td>89<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>56<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>67<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Flange 76 \u00d7 76; fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modell<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-02.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-03.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-04.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<h2>Auswahlhilfe<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Bestellinformationen<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP67 gerade Einbaubuchsen f\u00fcr feste industrielle Stromanschl\u00fcsse.<\/p>\n<ul>\n<li>Stromst\u00e4rken: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Kontaktbelegung: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Buchse mit Klappdeckel und Einbauflansch.<\/li>\n<li>Vollst\u00e4ndige Modellauswahltabellen enthalten Spannung, Position des Schutzkontakts, Leiterquerschnitte und geh\u00e4usespezifische Abmessungen.<\/li>\n<li>Auswahl und Anfrage \u00fcber vollst\u00e4ndigen NM-Modellcode.<\/li>\n<\/ul>","protected":false},"featured_media":2892,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2897","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product\/2897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media\/2892"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/media?parent=2897"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_brand?post=2897"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_cat?post=2897"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/de\/wp-json\/wp\/v2\/product_tag?post=2897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}