YOCL

HV/HVD Pre-Insulated Hook Terminals

YOCL ELECTRIC HV/HVD Pre-Insulated Hook Terminals connect copper conductors to bolted terminals. This combined series includes HV single-crimp and HVD double-crimp models in 13 matched pairs, covering 0.5–6 mm² conductor groups.

  • Copper terminals with PVC insulating sleeves in red, blue and yellow groups.
  • Choose HV or HVD construction, then select by conductor range and hook opening d2.
  • Model-specific B, F and L dimensions and group-specific E, D1 and D2 dimensions are listed below.
Inquire about this product

Overview

YOCL ELECTRIC HV/HVD Pre-Insulated Hook Terminals are copper hook terminals with PVC insulating sleeves for bolted conductor connections. HV identifies the single-crimp construction; HVD identifies the double-crimp construction with an additional copper tube and sleeve described in the supplied catalog. The 13 matched model pairs cover conductor groups from 0.5 to 6 mm².

Features

  • Hook-shaped contact: the open hook shape is shown for a compatible bolt or stud connection.
  • Two crimp constructions: HV single crimp and HVD double crimp share each listed hook and overall dimension pair; the barrel construction differs.
  • Copper and PVC materials: copper terminal material and PVC insulation are stated for all three groups.
  • Group-specific selection: conductor range, Imax, sleeve dimensions and material thickness are stated by group.

Technical Specifications

Parameter Specification
Product type Pre-insulated hook terminal
Series HV single crimp; HVD double crimp
Listed models 13 HV and 13 HVD
Terminal material Copper
Insulation PVC
HVD construction Additional copper tube with sleeve, described as double pressure in the source
Drawing dimension units mm

The source labels the current values Imax (maximum current). Each value applies to its corresponding conductor group; test and installation conditions are not given.

Model group Color Conductor range AWG Imax Material thickness E (mm) D1 (mm), HV D2 (mm), HVD
HV/HVD 1.25 Red 0.5–1.5 mm² AWG 22–16 19 A 0.7 mm 10.0 4.3 4.5
HV/HVD 2 Blue 1.5–2.5 mm² AWG 16–14 27 A 0.8 mm 10.0 4.9 5.2
HV/HVD 5.5 Yellow 4–6 mm² AWG 12–10 48 A 1.0 mm 13.0 6.7 7.0

Dimension

The drawing uses B, F, L and E for overall dimensions. The hook opening is d2; D1 applies to the HV barrel and D2 to the HVD barrel. All dimensions below are in millimeters.

HV single-crimp model HVD double-crimp model Color US bolt no. Hook opening d2 (mm) B (mm) F (mm) L (mm)
HV 1.25-3.5 HVD 1.25-3.5 Red #6 3.7 8.0 7.0 21.0
HV 1.25-4 HVD 1.25-4 Red #8 4.3 8.0 7.0 21.0
HV 1.25-5 HVD 1.25-5 Red #10 5.3 8.0 7.0 21.0
HV 1.25-6 HVD 1.25-6 Red 1/4 6.5 11.6 11.0 27.0
HV 2-3.5 HVD 2-3.5 Blue #6 3.7 8.5 7.4 22.0
HV 2-4 HVD 2-4 Blue #8 4.3 8.5 7.4 22.0
HV 2-5 HVD 2-5 Blue #10 5.3 9.5 7.3 22.0
HV 2-6 HVD 2-6 Blue 1/4 6.5 12.0 11.0 27.0
HV 5.5-3.5 HVD 5.5-3.5 Yellow #6 3.7 7.2 6.1 22.7
HV 5.5-4 HVD 5.5-4 Yellow #8 4.3 9.5 9.5 26.8
HV 5.5-5 HVD 5.5-5 Yellow #10 5.3 9.5 9.5 26.8
HV 5.5-6 HVD 5.5-6 Yellow 1/4 6.5 12.0 10.3 29.5
HV 5.5-8 HVD 5.5-8 Yellow 5/16 8.5 15.0 13.5 34.0

E, D1 and D2 are shared within each conductor group in the technical specification table above.

HV/HVD Pre-Insulated Hook Terminals dimension drawing

Selection Guide

Choose HV or HVD construction and the conductor group first. Then compare the hook opening d2 with the intended bolt or stud, and check B, F, L and the applicable barrel dimensions against available connection space. Use the exact HV or HVD model code when ordering.

Ordering Information

Specify the HV or HVD model and quantity when requesting a quotation.

Detalles del proyecto

Los campos marcados con * son obligatorios.

Sus datos se utilizarán para responder a su consulta. Aviso de privacidad