YOCL

FDD/FDVD Terminales Hembra Preaislantes (Crimpado Simple y Doble)

YOCL ELECTRIC FDD/FDVD female terminals pair a brass receptacle with a PVC insulating sleeve. FDD is the single-crimp version; FDVD adds a copper tube sleeve for double crimp.

  • 22 FDD and 22 matching FDVD models across three conductor groups.
  • Conductor sections: 0.5–1.5, 1.5–2.5 and 4–6 mm².
  • NEMA tab sizes and material thickness vary by model.
  • Compare B, D, d, L1, L2 and E in the dimensional table.
Inquire about this product

Overview

YOCL ELECTRIC FDD/FDVD Pre-insulating Female Terminals are brass female receptacles with PVC insulation. FDD models use a single crimp, while matching FDVD models use a double crimp with a copper tube sleeve. The source lists 22 paired rows across three conductor groups.

Features

  • Single and double crimp choices: matching FDD and FDVD model codes appear together in the table.
  • Brass receptacle and PVC sleeve: materials stated for the three conductor groups.
  • Tab selection: NEMA tab size and contact material thickness vary by model.
  • Size-based fit: barrel diameters, body lengths and terminal widths are given for each row.

Technical Specifications

Parameter Specification
Product type Pre-insulating female terminal
Series FDD (single crimp); FDVD (double crimp)
Terminal material Latón
Insulation PVC sleeve
Double-crimp construction Copper tube with sleeve
Listed models 22 FDD; 22 FDVD

The maximum current applies to the stated conductor group, not every model in the full series.

Size group Conductor section (mm²) AWG Max current (A) Color E (mm)
1.25 0.5–1.5 22–16 19 Red 10.0
2 1.5–2.5 16–14 27 Blue 10.0
5.5 4–6 12–10 48 Yellow 12.5

Dimension

All dimensions below are in millimeters. NEMA tab, material thickness, B, D, d, L1 and L2 follow the source table and drawings. E is given by conductor group above.

FDD single-crimp model FDVD double-crimp model NEMA tab (mm) Material thickness (mm) B (mm) D (mm) d (mm) L1 (mm) L2 (mm)
FDD1.25-110(5) FDVD1.25-110(5) 0.5 × 2.8 0.3 3.3 3.8 1.7 18.5 20.0
FDD1.25-110(8) FDVD1.25-110(8) 0.8 × 2.8 0.3 3.3 3.8 1.7 18.5 20.0
FDD1.25-187(5) FDVD1.25-187(5) 0.5 × 4.75 0.35 5.0 3.8 1.7 19.0 20.5
FDD1.25-187(8) FDVD1.25-187(8) 0.8 × 4.75 0.35 5.0 3.8 1.7 19.0 20.5
FDD1.25-205 FDVD1.25-205 0.5 × 5.2 0.35 5.7 3.8 1.7 19.0 20.5
FDD1.25-250 FDVD1.25-250 0.8 × 6.35 0.4 6.6 3.8 1.7 19.8 21.3
FDD1.25-312 FDVD1.25-312 0.8 × 8.0 0.4 8.2 3.8 1.7 23.0 24.5
FDD2-110(5) FDVD2-110(5) 0.5 × 2.8 0.3 3.3 4.3 2.3 18.5 20.0
FDD2-110(8) FDVD2-110(8) 0.8 × 2.8 0.3 3.3 4.3 2.3 18.5 20.0
FDD2-187(5) FDVD2-187(5) 0.5 × 4.75 0.35 5.0 4.3 2.3 19.0 20.5
FDD2-187(8) FDVD2-187(8) 0.8 × 4.75 0.35 5.0 4.3 2.3 19.0 20.5
FDD2-205 FDVD2-205 0.5 × 5.2 0.35 5.7 4.3 2.3 19.0 20.5
FDD2-250 FDVD2-250 0.8 × 6.35 0.4 6.6 4.3 2.3 19.0 20.5
FDD2-312 FDVD2-312 0.8 × 8.0 0.4 8.2 4.3 2.3 23.7 25.2
FDD2-375 FDVD2-375 1.2 × 9.4 0.5 9.9 4.3 2.3 27.6 29.1
FDD5.5-110 × 5 FDVD5.5-110 × 5 0.5 × 2.8 0.35 3.3 5.7 3.4 21.0 22.5
FDD5.5-110 × 8 FDVD5.5-110 × 8 0.8 × 2.8 0.35 3.3 5.7 3.4 21.0 22.5
FDD5.5-187 × 5 FDVD5.5-187 × 5 0.5 × 4.75 0.4 5.0 5.7 3.4 22.0 23.5
FDD5.5-187 × 8 FDVD5.5-187 × 8 0.8 × 4.75 0.4 5.0 5.7 3.4 22.0 23.5
FDD5.5-250 FDVD5.5-250 0.8 × 6.35 0.4 6.6 5.7 3.4 23.4 24.9
FDD5.5-312 FDVD5.5-312 0.8 × 8.0 0.5 8.2 5.7 3.4 27.3 28.8
FDD5.5-375 FDVD5.5-375 1.2 × 9.4 0.5 9.9 5.7 3.4 29.6 31.1

FDD/FDVD Pre-insulating Female Terminals (Single and Double Crimp) dimension drawing

Selection Guide

Select the FDD or FDVD crimp style, then match the conductor section and NEMA tab size to the mating terminal. Compare material thickness and B, D, d, L1, L2 and E dimensions with the available space.

Aplicaciones

For compatible female tab connections in electrical equipment.

Ordering Information

Provide the full FDD or FDVD model and quantity when requesting a quotation.

Detalles del proyecto

Los campos marcados con * son obligatorios.

Sus datos se utilizarán para responder a su consulta. Aviso de privacidad