Terminales de horquilla no aislados SNB (tipo TU)

SNB TU-type non-insulated fork terminals are copper terminals for bolted conductor connections. The source lists 43 models with distinct fork widths, bolt-hole sizes and body dimensions.

  • Listed conductor groups span 0.5–10 mm²; the 14 and 22 groups have no stated conductor range.
  • Group-specific Imax values range from 19 to 115 A in the catalog.
  • Choose by exact model, conductor group and bolt-hole diameter.
Consultar sobre este producto

Descripción general

SNB Non-Insulated Fork Terminals (TU Type) are copper fork terminals for bolted conductor connections. The supplied catalog lists 43 models across seven SNB groups, with group-specific material thickness and Imax values.

Características

  • Non-insulated copper construction: the source identifies a bare copper terminal with no insulating sleeve.
  • Fork connection: the fork tip is designed for a bolted connection; its bolt hole is listed for each model.
  • Model-specific geometry: B, F and L vary by model, while E, D and d are specified by group.

Especificaciones técnicas

Parámetro Especificación
Tipo de producto Non-insulated fork terminal, TU type
Serie SNB
Listed models 43
Material Copper
Dimension units mm

The catalog calls the current figures Imax. They apply to their respective groups; no test or installation conditions are given. For SNB 14 and SNB 22, the source does not state a conductor section or AWG range.

Group Conductor section AWG Imax Material thickness (mm) E (mm) D (mm) d (mm)
SNB 1.25 0.5–1.5 mm² 22–16 19 A 0.7 4.8 3.4 1.7
SNB 2 1.5–2.5 mm² 16–14 27 A 0.8 4.8 4.1 2.3
SNB 3.5 2.5–4 mm² 14–12 37 A 1.0 6.0 5.0 3.0
SNB 5.5 4–6 mm² 12–10 48 A 1.0 6.0 5.6 3.4
SNB 8 8–10 mm² 8 62 A 1.2 8.5 7.2 4.5
SNB 14 Not stated Not stated 88 A 1.5 10.5 9.0 5.8
SNB 22 Not stated Not stated 115 A 1.7 12 11.5 7.7

Dimensión

The drawing labels the fork bolt-hole diameter d2 and the dimensions B, F, L, E, D and d. All figures below are in millimeters. Values for E, D and d are repeated by model to make selection straightforward.

Modelo US bolt no. Bolt-hole d2 (mm) B (mm) F (mm) L (mm) E (mm) D (mm) d (mm)
SNB 1.25-3 #4 3.2 5.7 6.5 16.0 4.8 3.4 1.7
SNB 1.25-3.5S #6 3.7 5.7 6.5 16.0 4.8 3.4 1.7
SNB 1.25-3.5L #6 3.7 6.4 6.5 16.0 4.8 3.4 1.7
SNB 1.25-4S #8 4.3 6.4 6.5 16.0 4.8 3.4 1.7
SNB 1.25-4M #8 4.3 7.2 6.5 16.0 4.8 3.4 1.7
SNB 1.25-4L #8 4.3 8.1 6.5 16.0 4.8 3.4 1.7
SNB 1.25-5S #10 5.3 8.1 6.5 16.0 4.8 3.4 1.7
SNB 1.25-5L #10 5.3 9.5 6.5 16.0 4.8 3.4 1.7
SNB 1.25-6S 1/4 6.5 9.5 6.5 16.0 4.8 3.4 1.7
SNB 1.25-6L 1/4 6.5 12.0 11.0 22.0 4.8 3.4 1.7
SNB 1.25-8 5/16 8.5 14.0 12.0 23.5 4.8 3.4 1.7
SNB 2-3 #4 3.2 5.7 6.5 16.0 4.8 4.1 2.3
SNB 2-3.5S #6 3.7 5.7 6.5 16.0 4.8 4.1 2.3
SNB 2-3.5L #6 3.7 6.4 6.5 16.0 4.8 4.1 2.3
SNB 2-4S #8 4.3 6.4 6.5 16.0 4.8 4.1 2.3
SNB 2-4M #8 4.3 7.2 6.5 16.0 4.8 4.1 2.3
SNB 2-4L #8 4.3 8.1 6.5 16.0 4.8 4.1 2.3
SNB 2-5S #10 5.3 8.1 6.5 16.0 4.8 4.1 2.3
SNB 2-5L #10 5.3 9.5 6.5 16.0 4.8 4.1 2.3
SNB 2-6S 1/4 6.5 9.5 6.5 16.0 4.8 4.1 2.3
SNB 2-6L 1/4 6.5 12.0 11.0 22.0 4.8 4.1 2.3
SNB 2-8 5/16 8.5 14.0 12.5 23.5 4.8 4.1 2.3
SNB 3.5-3.5 #6 3.7 8.0 7.0 18.3 6.0 5.0 3.0
SNB 3.5-4 #8 4.3 8.0 7.0 18.3 6.0 5.0 3.0
SNB 3.5-5S #10 5.3 8.0 7.0 18.3 6.0 5.0 3.0
SNB 3.5-6S 1/4 6.5 9.0 7.5 19.5 6.0 5.0 3.0
SNB 3.5-6 1/4 6.5 12.0 12.1 21.5 6.0 5.0 3.0
SNB 5.5-3.5 #6 3.7 8.3 7.5 19.5 6.0 5.6 3.4
SNB 5.5-4S #8 4.3 8.3 7.5 19.5 6.0 5.6 3.4
SNB 5.5-4L #8 4.3 9.0 7.5 19.5 6.0 5.6 3.4
SNB 5.5-5 #10 5.3 9.0 7.5 19.5 6.0 5.6 3.4
SNB 5.5-6S 1/4 6.5 9.0 7.5 19.5 6.0 5.6 3.4
SNB 5.5-6L 1/4 6.5 12.0 12.0 25.5 6.0 5.6 3.4
SNB 5.5-8 5/16 8.5 14.0 11.5 24.5 6.0 5.6 3.4
SNB 8-4 #8 4.3 8.0 7.2 23.0 8.5 7.2 4.5
SNB 8-5S #10 5.3 10.8 7.2 21.5 8.5 7.2 4.5
SNB 8-5 #10 5.3 10.8 7.2 23.0 8.5 7.2 4.5
SNB 8-6 5/16 8.5 14.5 10.7 23.0 8.5 7.2 4.5
SNB 8-8 5/16 8.5 11.0 10.7 28.0 8.5 7.2 4.5
SNB 14-6 1/4 6.5 11.0 10.7 28.0 10.5 9.0 5.8
SNB 14-8 5/16 8.5 14.0 10.7 28.0 10.5 9.0 5.8
SNB 22-6 1/4 6.5 14.0 9.5 34.5 12 11.5 7.7
SNB 22-8 5/16 8.5 14.0 13.5 34.5 12 11.5 7.7

SNB Non-Insulated Fork Terminals (TU Type) dimension drawing