{"id":2454,"date":"2026-10-06T12:34:25","date_gmt":"2026-10-06T12:34:25","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=cf559107b82a3d9cf45835dd6dfd355c3fc2ed3843accced2ba6439eaf2784e5"},"modified":"2026-10-06T12:34:25","modified_gmt":"2026-10-06T12:34:25","slug":"heat-shrink-tubing-size-chart","status":"publish","type":"post","link":"https:\/\/yocl.com\/es\/heat-shrink-tubing-size-chart\/","title":{"rendered":"Tabla de tama\u00f1os de tubo termorretr\u00e1ctil: di\u00e1metros expandido y recuperado"},"content":{"rendered":"<p><strong>Lea una tabla de tama\u00f1os de tubo termorretr\u00e1ctil utilizando dos di\u00e1metros interiores: el di\u00e1metro expandido antes de calentar y el di\u00e1metro recuperado libremente despu\u00e9s de encoger.<\/strong> El di\u00e1metro suministrado debe ser mayor que la caracter\u00edstica m\u00e1s grande; el di\u00e1metro recuperado debe ser menor que la superficie que necesita sujetar. Utilice los l\u00edmites de fila reales, en lugar de dividir un tama\u00f1o nominal por la relaci\u00f3n de contracci\u00f3n.<\/p>\n<p>Las tablas a continuaci\u00f3n reproducen <strong>entradas de tama\u00f1o 61 en tres series YOCL<\/strong>. Todas las dimensiones est\u00e1n en <strong>mil\u00edmetros<\/strong>. Son declaraciones de producto espec\u00edficas de la serie, no una tabla universal para cada material termorretr\u00e1ctil.<\/p>\n<h2>YOCL tablas de tama\u00f1os de tubo termorretr\u00e1ctil<\/h2>\n<h3>Aproximadamente 2:1 tubo de pared simple \u2014 HTS<\/h3>\n<p>La <a href=\"https:\/\/yocl.com\/es\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">YOCL tabla de dimensiones HTS<\/a> proporciona tama\u00f1os nominales emparejados y campos antes\/despu\u00e9s de encoger con <strong>tolerancias \u00b1<\/strong>. Mantenga esas tolerancias al leer un tama\u00f1o como 12.0\/6.0; el par no significa que ambos di\u00e1metros sean exactos.<\/p>\n<table>\n<thead>\n<tr>\n<th>Par de tama\u00f1os nominales (mm)<\/th>\n<th>ID antes de encoger (mm)<\/th>\n<th>Campo post-encogimiento\u2020 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1.0\/0.5<\/td>\n<td>1.0 \u00b1 0.3<\/td>\n<td>0.5 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>1.5\/0.75<\/td>\n<td>1.5 \u00b1 0.3<\/td>\n<td>0.75 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>2.0\/1.0<\/td>\n<td>2.0 \u00b1 0.3<\/td>\n<td>1.0 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>2.5\/1.25<\/td>\n<td>2.5 \u00b1 0.3<\/td>\n<td>1.25 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>3.0\/1.5<\/td>\n<td>3.0 \u00b1 0.3<\/td>\n<td>1.5 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>3.5\/1.75<\/td>\n<td>3.5 \u00b1 0.3<\/td>\n<td>1.75 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>4.0\/2.0<\/td>\n<td>4.0 \u00b1 0.3<\/td>\n<td>2.0 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td>5.0\/2.5<\/td>\n<td>5.0 \u00b1 0.3<\/td>\n<td>2.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>6.0\/3.0<\/td>\n<td>6.0 \u00b1 0.4<\/td>\n<td>3.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>7.0\/3.5<\/td>\n<td>7.0 \u00b1 0.4<\/td>\n<td>3.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>8.0\/4.0<\/td>\n<td>8.0 \u00b1 0.4<\/td>\n<td>4.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>9.0\/4.5<\/td>\n<td>9.0 \u00b1 0.4<\/td>\n<td>4.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>10.0\/5.0<\/td>\n<td>10.0 \u00b1 0.4<\/td>\n<td>5.0 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>11.0\/5.5<\/td>\n<td>11.0 \u00b1 0.4<\/td>\n<td>5.5 \u00b1 0.2<\/td>\n<\/tr>\n<tr>\n<td>12.0\/6.0<\/td>\n<td>12.0 \u00b1 0.4<\/td>\n<td>6.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>13.0\/6.5<\/td>\n<td>13.0 \u00b1 0.4<\/td>\n<td>6.5 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>14.0\/7.0<\/td>\n<td>14.0 \u00b1 0.4<\/td>\n<td>7.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>15.0\/7.5<\/td>\n<td>15.0 \u00b1 0.4<\/td>\n<td>7.5 \u00b1 0.4<\/td>\n<\/tr>\n<tr>\n<td>16.0\/8.0<\/td>\n<td>16.0 \u00b1 0.5<\/td>\n<td>8.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>17.0\/8.5<\/td>\n<td>17.0 \u00b1 0.5<\/td>\n<td>8.5 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>18.0\/9.0<\/td>\n<td>18.0 \u00b1 0.5<\/td>\n<td>9.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>20.0\/10.0<\/td>\n<td>20.0 \u00b1 0.5<\/td>\n<td>10.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>22.0\/11.0<\/td>\n<td>22.0 \u00b1 0.5<\/td>\n<td>11.0 \u00b1 0.3<\/td>\n<\/tr>\n<tr>\n<td>25.0\/12.5<\/td>\n<td>25.0 \u00b1 0.8<\/td>\n<td>12.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>28.0\/14.0<\/td>\n<td>28.0 \u00b1 0.8<\/td>\n<td>14.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>30.0\/15.0<\/td>\n<td>30.0 \u00b1 0.8<\/td>\n<td>15.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>35.0\/17.5<\/td>\n<td>35.0 \u00b1 0.8<\/td>\n<td>17.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>40.0\/20.0<\/td>\n<td>40.0 \u00b1 1.5<\/td>\n<td>20.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>45.0\/22.5<\/td>\n<td>45.0 \u00b1 1.5<\/td>\n<td>22.5 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>50.0\/25.0<\/td>\n<td>50.0 \u00b1 1.5<\/td>\n<td>25.0 \u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td>60.0\/30.0<\/td>\n<td>60.0 \u00b1 1.5<\/td>\n<td>30.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>70.0\/35.0<\/td>\n<td>70.0 \u00b1 1.5<\/td>\n<td>35.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>80.0\/40.0<\/td>\n<td>80.0 \u00b1 1.5<\/td>\n<td>40.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>90.0\/45.0<\/td>\n<td>90.0 \u00b1 1.5<\/td>\n<td>45.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>100.0\/50.0<\/td>\n<td>100.0 \u00b1 1.5<\/td>\n<td>50.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>120.0\/60.0<\/td>\n<td>120.0 \u00b1 1.5<\/td>\n<td>60.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>150.0\/75.0<\/td>\n<td>150.0 \u00b1 1.5<\/td>\n<td>75.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>180.0\/90.0<\/td>\n<td>180.0 \u00b1 1.5<\/td>\n<td>90.0 \u00b1 1.5<\/td>\n<\/tr>\n<tr>\n<td>200.0\/100.0<\/td>\n<td>200.0 \u00b1 1.5<\/td>\n<td>100.0 \u00b1 1.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u2020 La fuente titula su columna posterior al encogimiento como \u201cM\u00e1x. I.D. despu\u00e9s de encoger\u201d al enumerar valores \u00b1. Dichos valores se reproducen aqu\u00ed sin cambios, en lugar de reformularse como l\u00edmites no cualificados. Obtenga los l\u00edmites definitivos de suministro\/recuperaci\u00f3n para el tama\u00f1o HTS elegido antes de aprobar un ajuste cercano a cualquiera de los l\u00edmites.<\/p>\n<h3>3:1 tubo con adhesivo \u2014 HS3X<\/h3>\n<p>La <a href=\"https:\/\/yocl.com\/es\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL HS3X tabla de dimensiones<\/a> indica un <strong>ID m\u00ednimo suministrado<\/strong> y <strong>ID m\u00e1ximo recuperado<\/strong>. Las entradas m\u00e9tricas a continuaci\u00f3n conservan los valores publicados de YOCL; no se recalculan a partir de las etiquetas de tama\u00f1o en fracciones de pulgada.<\/p>\n<table>\n<thead>\n<tr>\n<th>Tama\u00f1o m\u00e9trico de entrada (mm)<\/th>\n<th>ID suministrado (mm), m\u00ednimo<\/th>\n<th>ID recuperado (mm), m\u00e1ximo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2.4<\/td>\n<td>\u22652.4<\/td>\n<td>\u22640.8<\/td>\n<\/tr>\n<tr>\n<td>3.2<\/td>\n<td>\u22653.2<\/td>\n<td>\u22641.0<\/td>\n<\/tr>\n<tr>\n<td>4.8<\/td>\n<td>\u22654.8<\/td>\n<td>\u22641.6<\/td>\n<\/tr>\n<tr>\n<td>6.4<\/td>\n<td>\u22656.4<\/td>\n<td>\u22642.2<\/td>\n<\/tr>\n<tr>\n<td>7.9<\/td>\n<td>\u22657.9<\/td>\n<td>\u22642.7<\/td>\n<\/tr>\n<tr>\n<td>9.5<\/td>\n<td>\u22659.5<\/td>\n<td>\u22643.2<\/td>\n<\/tr>\n<tr>\n<td>12.7<\/td>\n<td>\u226512.7<\/td>\n<td>\u22644.2<\/td>\n<\/tr>\n<tr>\n<td>15.0<\/td>\n<td>\u226515.0<\/td>\n<td>\u22645.2<\/td>\n<\/tr>\n<tr>\n<td>19.1<\/td>\n<td>\u226519.1<\/td>\n<td>\u22646.3<\/td>\n<\/tr>\n<tr>\n<td>25.4<\/td>\n<td>\u226525.4<\/td>\n<td>\u22648.5<\/td>\n<\/tr>\n<tr>\n<td>30.0<\/td>\n<td>\u226530.0<\/td>\n<td>\u226410.2<\/td>\n<\/tr>\n<tr>\n<td>39.0<\/td>\n<td>\u226539.0<\/td>\n<td>\u226413.5<\/td>\n<\/tr>\n<tr>\n<td>50.0<\/td>\n<td>\u226550.0<\/td>\n<td>\u226417.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>4:1 tubo con adhesivo \u2014 HS4X<\/h3>\n<p>La <a href=\"https:\/\/yocl.com\/es\/product\/hs4x-4-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">YOCL HS4X tabla de dimensiones<\/a> utiliza pares de tama\u00f1os suministrados\/recuperados y l\u00edmites expl\u00edcitos de \u2265\/\u2264. Por ejemplo, 16.0\/4.0 identifica un di\u00e1metro interior suministrado de al menos 16.0 mm y un di\u00e1metro interior recuperado de no m\u00e1s de 4.0 mm.<\/p>\n<table>\n<thead>\n<tr>\n<th>Tama\u00f1o m\u00e9trico de entrada (mm)<\/th>\n<th>ID suministrado (mm), m\u00ednimo<\/th>\n<th>ID recuperado (mm), m\u00e1ximo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4.0\/1.0<\/td>\n<td>\u22654.0<\/td>\n<td>\u22641.0<\/td>\n<\/tr>\n<tr>\n<td>6.0\/1.5<\/td>\n<td>\u22656.0<\/td>\n<td>\u22641.5<\/td>\n<\/tr>\n<tr>\n<td>8.0\/2.0<\/td>\n<td>\u22658.0<\/td>\n<td>\u22642.0<\/td>\n<\/tr>\n<tr>\n<td>12.0\/3.0<\/td>\n<td>\u226512.0<\/td>\n<td>\u22643.0<\/td>\n<\/tr>\n<tr>\n<td>16.0\/4.0<\/td>\n<td>\u226516.0<\/td>\n<td>\u22644.0<\/td>\n<\/tr>\n<tr>\n<td>20.0\/5.0<\/td>\n<td>\u226520.0<\/td>\n<td>\u22645.0<\/td>\n<\/tr>\n<tr>\n<td>24.0\/6.0<\/td>\n<td>\u226524.0<\/td>\n<td>\u22646.0<\/td>\n<\/tr>\n<tr>\n<td>32.0\/8.0<\/td>\n<td>\u226532.0<\/td>\n<td>\u22648.0<\/td>\n<\/tr>\n<tr>\n<td>52.0\/13.0<\/td>\n<td>\u226552.0<\/td>\n<td>\u226413.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Estas tablas cubren solo HTS, HS3X y HS4X. Otros tipos de pared simple, semirr\u00edgidos, barras colectoras o grados especializados necesitan sus propias tablas de dimensiones; una relaci\u00f3n de coincidencia no hace que sus tama\u00f1os sean intercambiables.<\/p>\n<h2>Los di\u00e1metros expandido, recuperado e instalado son estados diferentes<\/h2>\n<p><strong>Di\u00e1metro interior (ID)<\/strong> mide el orificio del tubo. <strong>Di\u00e1metro exterior (OD)<\/strong> mide el cable o componente que debe rodear.<\/p>\n<ul>\n<li><strong>Expandido\/suministrado:<\/strong> the bore available before heating, used for the pass-over check.<\/li>\n<li><strong>Recuperado libremente:<\/strong> the bore reached under specified recovery conditions without an internal object restricting contraction.<\/li>\n<li><strong>Instalado:<\/strong> the sleeve conforms around the object. A cable that is larger than the free-recovery bore prevents it reaching that bore.<\/li>\n<\/ul>\n<p>For the HS4X 12.0\/3.0 row, the two catalogue fields are \u226512.0 mm supplied and \u22643.0 mm recovered. Neither field promises that an installed sleeve around a larger cable will have a 3.0 mm bore.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/heat-shrink-tubing-size-chart-diameter-states.webp\" alt=\"End-on schematic showing expanded and freely recovered inside-diameter limits for YOCL HS4X 12.0\/3.0 tubing, with arrows across the bore.\"><figcaption>HS4X 12.0\/3.0 catalogue limits. Schematic, not to scale; an internal object restricts recovery and changes the installed state.<\/figcaption><\/figure>\n<p>Read the signs as part of the specification: <strong>\u2265<\/strong> supplies a lower bound; <strong>\u2264<\/strong> supplies an upper bound; <strong>\u00b1<\/strong> retains variation around the stated value. Do not erase these signs when copying dimensions into an enquiry.<\/p>\n<p>Also keep the nominal ratio separate. The HS3X 6.4 mm entry lists a recovered limit of <strong>\u22642.2 mm<\/strong>, while 6.4 \u00f7 3 is approximately 2.13 mm. Replacing 2.2 with that calculation would change the published specification.<\/p>\n<p>For the wider terminology map, see <a href=\"https:\/\/yocl.com\/es\/what-is-heat-shrink-tubing\/\">\u00bfQu\u00e9 es el tubo termorretr\u00e1ctil? Relaciones, paredes y revestimientos adhesivos<\/a>.<\/p>\n<h2>Use both diameter limits from the same row<\/h2>\n<p>For a preliminary check of <strong>round parts and open-ended tubing<\/strong>, identify:<\/p>\n<ul>\n<li><strong>Largest pass-over OD:<\/strong> the widest round feature the unshrunk sleeve must cross, including a connector or joint.<\/li>\n<li><strong>Smallest covered OD:<\/strong> the narrowest round cable surface onto which the sleeve needs to recover.<\/li>\n<\/ul>\n<p>Then compare both dimensions with one size row:<\/p>\n<p><strong>Minimum supplied ID &gt; largest pass-over OD<\/strong><\/p>\n<p><strong>Maximum freely recovered ID &lt; smallest covered OD<\/strong><\/p>\n<p>de la NASA <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revisi\u00f3n F, \u00a73.8.1.1.1(a)<\/a> documents this expanded-larger\/recovered-smaller relationship for electrical ground-support-equipment fabrication. It supports the dimensional principle, rather than approval of a YOCL assembly.<\/p>\n<p>Equality leaves no dimensional margin. Include component tolerances and the model&#8217;s installation allowance; this chart does not prescribe a universal clearance percentage. Flat busbars, irregular connectors and bundles need a geometry review rather than a single round-diameter comparison.<\/p>\n<h3>Worked example: a 14 mm feature and a 5 mm cable<\/h3>\n<p>Assume the largest round feature is <strong>14 mm OD<\/strong> and the smallest cable jacket is <strong>5 mm OD<\/strong>. These are illustrative inputs, not measurements of a particular installation.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/heat-shrink-tubing-size-chart-pass-over-dimensions.webp\" alt=\"Illustrative round connection with a 14 mm outside-diameter feature and a 5 mm cable jacket, identifying the two dimensions used in the tubing-fit example.\"><figcaption>Measure the largest pass-over feature and the smallest covered surface separately. These illustrative dimensions are the inputs to the table below.<\/figcaption><\/figure>\n<table>\n<thead>\n<tr>\n<th>Series and metric size<\/th>\n<th>Minimum supplied ID<\/th>\n<th>Maximum recovered ID<\/th>\n<th>Supplied minimum &gt;14 mm?<\/th>\n<th>Recovered maximum &lt;5 mm?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>HS3X 12.7 mm<\/td>\n<td>12.7 mm<\/td>\n<td>4.2 mm<\/td>\n<td>No establecido<\/td>\n<td>Superado<\/td>\n<\/tr>\n<tr>\n<td>HS3X 15.0 mm<\/td>\n<td>15.0 mm<\/td>\n<td>5.2 mm<\/td>\n<td>Superado<\/td>\n<td>No establecido<\/td>\n<\/tr>\n<tr>\n<td>HS4X 16.0\/4.0 mm<\/td>\n<td>16.0 mm<\/td>\n<td>4.0 mm<\/td>\n<td>Superado<\/td>\n<td>Superado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>HS4X 16.0\/4.0 passes both dimensional inequalities for these inputs.<\/strong> It remains a candidate requiring application review. The HS3X 12.7 row does not establish clearance over 14 mm. Moving up to HS3X 15.0 establishes that clearance, but its 5.2 mm recovered upper limit does not establish contraction below a 5 mm jacket.<\/p>\n<p>\u201cNot established\u201d does not claim every specimen will fail. It means the published bound is insufficient to assure that check. Choose the nearest listed row that satisfies <strong>both<\/strong> requirements with the specified allowance, rather than simply taking the next larger size.<\/p>\n<h2>What the diameter chart does not decide<\/h2>\n<p>Measure the actual insulated cable OD. <strong>American Wire Gauge (AWG)<\/strong> or conductor cross-sectional area does not specify the jacket diameter, and a flattened sleeve&#8217;s width is not its inside diameter. A nominal fractional-inch label likewise cannot replace the model&#8217;s stated diameter fields.<\/p>\n<p>The installed sleeve also needs enough space and coverage. Check wall thickness with its measurement state, finished outside dimensions and the product&#8217;s longitudinal-change information. Do not assume a freely recovered wall value is the wall on a partly recovered cable, or apply the diameter shrink ratio to cut length. Where a wall field is labelled \u201ctotal\u201d, do not add its adhesive thickness again.<\/p>\n<p>For the liner decision, use <a href=\"https:\/\/yocl.com\/es\/single-wall-vs-dual-wall-heat-shrink-tubing\/\">Tubos termorretr\u00e1ctiles de pared simple vs. pared doble<\/a>. A successful diameter check alone establishes neither an electrical rating nor a sealed connection.<\/p>\n<p>To confirm a size, use the <a href=\"https:\/\/yocl.com\/es\/heat-shrink-tubing-manufacturer\/\">Cat\u00e1logo de tubos termorretr\u00e1ctiles YOCL<\/a> and provide the series, exact size row, largest pass-over dimension, smallest covered dimension and required coverage length. Request the applicable dimensional limits and installation information for the intended material and duty.<\/p>\n<h2>Referencias<\/h2>\n<ol>\n<li>Informaci\u00f3n del producto YOCL \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/hts-2-1-single-wall-heat-shrink-tubing\/\">HTS 2:1 Tubo termorretr\u00e1ctil de pared simple<\/a>. Complete 39-row dimension table, nominal pair meaning and published \u00b1 fields; checked 6 October 2026.<\/li>\n<li>Informaci\u00f3n del producto YOCL \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/hs3x-3-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS3X 3:1 Tubo termorretr\u00e1ctil de doble pared con adhesivo<\/a>. Complete 13-row dimension table and supplied\/recovered limits; checked 6 October 2026.<\/li>\n<li>Informaci\u00f3n del producto YOCL \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/hs4x-4-1-dual-wall-adhesive-lined-heat-shrink-tubing\/\">HS4X 4:1 Tubo termorretr\u00e1ctil de doble pared con adhesivo<\/a>. Complete nine-row dimension table and supplied\/recovered limits; checked 6 October 2026.<\/li>\n<li>Centro Espacial Kennedy de la NASA \u2014 <a href=\"https:\/\/standards.nasa.gov\/sites\/default\/files\/standards\/KSC\/F\/KSC-E-165-REV-F.pdf\" target=\"_blank\" rel=\"noopener\">KSC-E-165 Revision F, 20 December 2021<\/a>, <em>Electrical Ground Support Equipment Fabrication, Specification for<\/em>. Section 3.8.1.1.1(a), printed page 59; dimensional principle within its ground-support-equipment scope.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Read a heat shrink tubing size chart using two inside diameters: the expanded bore before heating and the freely recovered bore after shrinking. The supplied bore must clear the largest feature; the recovered bore must be smaller than the surface it needs to grip. Use the actual row limits, rather than dividing a nominal size [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2453,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[165],"tags":[],"class_list":["post-2454","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heat-shrink-insulation"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/2454","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/comments?post=2454"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/2454\/revisions"}],"predecessor-version":[{"id":2455,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/2454\/revisions\/2455"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/2453"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=2454"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/categories?post=2454"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/tags?post=2454"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}