{"id":3160,"date":"2026-10-12T02:23:06","date_gmt":"2026-10-12T02:23:06","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=c21635a44e341af8d80099e3f899435c0e760ca29d9767c937286b7c6ec9f1f8"},"modified":"2026-10-12T10:33:41","modified_gmt":"2026-10-12T10:33:41","slug":"cable-tie-size-and-tensile-strength-chart","status":"publish","type":"post","link":"https:\/\/yocl.com\/es\/cable-tie-size-and-tensile-strength-chart\/","title":{"rendered":"Tabla de tama\u00f1o y resistencia a la tracci\u00f3n de bridas: c\u00f3mo leer los datos"},"content":{"rendered":"<p><strong>Lea cada fila de brida como cuatro especificaciones separadas: longitud, ancho real de la correa, di\u00e1metro m\u00e1ximo del haz y fuerza de tracci\u00f3n declarada.<\/strong> El c\u00f3digo del modelo por s\u00ed solo no puede establecer el ajuste ni la capacidad de carga.<\/p>\n<h2>Tabla de tama\u00f1o y resistencia a la tracci\u00f3n de bridas YC YOCL<\/h2>\n<p>Seleccionado <a href=\"https:\/\/yocl.com\/es\/product\/yc-standard-nylon-cable-ties\/\">Filas de nailon est\u00e1ndar YC<\/a>; las columnas de fuerza muestran equivalentes de cat\u00e1logo redondeados, no clasificaciones de carga de trabajo.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo YC<\/th>\n<th align=\"right\">Longitud (mm)<\/th>\n<th align=\"right\">Ancho real (mm)<\/th>\n<th align=\"right\">Di\u00e1metro m\u00e1x. del mazo (mm)<\/th>\n<th align=\"right\">Tracci\u00f3n declarada (lbf)<\/th>\n<th align=\"right\">Equivalente listado (kgf)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YC-3\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2.4<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">18<\/td>\n<td align=\"right\">8<\/td>\n<\/tr>\n<tr>\n<td>YC-4\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">3.4<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">40<\/td>\n<td align=\"right\">18<\/td>\n<\/tr>\n<tr>\n<td>YC-5\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">4.8<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">22<\/td>\n<\/tr>\n<tr>\n<td>YC-5\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">4.8<\/td>\n<td align=\"right\">82<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">22<\/td>\n<\/tr>\n<tr>\n<td>YC-8\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">7.6<\/td>\n<td align=\"right\">82<\/td>\n<td align=\"right\">120<\/td>\n<td align=\"right\">55<\/td>\n<\/tr>\n<tr>\n<td>YC-12\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">12<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">91<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>YC-5<\/strong> es un c\u00f3digo de familia; el ancho real aqu\u00ed es <strong>4.8 mm<\/strong>.<\/p>\n<h2>Lea los cuatro campos en orden<\/h2>\n<p><strong>Longitud<\/strong> es la longitud total indicada de la brida. <strong>Anchura<\/strong> es el ancho real de la correa, le\u00eddo de su propia columna. <strong>Di\u00e1metro m\u00e1ximo del haz<\/strong> es el di\u00e1metro m\u00e1ximo de bulto declarado para ese modelo. Utilice este campo de di\u00e1metro para comprobar el ajuste; no lo calcule solo a partir de la longitud. <strong>Resistencia a la tracci\u00f3n<\/strong> es una cifra de fuerza con su unidad indicada, no un tama\u00f1o de bulto ni una capacidad de soporte sostenido.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/cable-tie-size-and-tensile-strength-chart-dimensions.webp\" alt=\"Cable tie showing overall length, strap width and bundle diameter\"><figcaption>Dimensiones conceptuales; compruebe el di\u00e1metro m\u00e1ximo de bulto declarado de cada modelo.<\/figcaption><\/figure>\n<p>No existe un c\u00e1lculo universal de longitud a haz: utilice el campo de di\u00e1metro declarado del modelo. <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\">UL Gu\u00eda de bridas para cables de Solutions<\/a> trata el di\u00e1metro del haz como un l\u00edmite de selecci\u00f3n recomendado por el fabricante.<\/p>\n<p>Tome una medida <strong>60 mm de haz<\/strong> como ejercicio de lectura. Una fila con un <strong>50 mm<\/strong> m\u00e1ximo falla la comprobaci\u00f3n de di\u00e1metro; un <strong>82 mm<\/strong> m\u00e1ximo pasa esa comprobaci\u00f3n. Pasarla no establece cu\u00e1nta carga continua puede soportar la brida, si su material se adapta al entorno, o cu\u00e1nto espacio hay disponible para pasar la cola por su cabeza. Mantenga su di\u00e1metro medido separado del l\u00edmite declarado por el fabricante; la tabla no es una medida de su instalaci\u00f3n.<\/p>\n<h2>Dos comparaciones que hacen \u00fatil el gr\u00e1fico<\/h2>\n<p><strong>YC-5\u00d7200 \u2192 YC-5\u00d7300:<\/strong> el ancho y la fuerza permanecen <strong>4.8 mm \/ 50 lbf<\/strong>; el l\u00edmite del haz aumenta <strong>50 \u2192 82 mm<\/strong>.<\/p>\n<p><strong>YC-5\u00d7300 \u2192 YC-8\u00d7300:<\/strong> ambos son <strong>300 mm<\/strong> largo con un <strong>82 mm<\/strong> l\u00edmite de haz; el ancho aumenta <strong>4.8 \u2192 7.6 mm<\/strong> y fuerza declarada <strong>50 \u2192 120 lbf<\/strong>. Estos pares de cat\u00e1logo no establecen una f\u00f3rmula de ancho a resistencia.<\/p>\n<p>Para cualquier comparaci\u00f3n nueva, copie el <strong>fila completa<\/strong> para cada modelo y marca exactos y se indica qu\u00e9 se mantuvo igual, qu\u00e9 cambi\u00f3 y qu\u00e9 deja la tabla sin especificar. Tomar la longitud de una fila, el ancho de otra y la fuerza de una tercera puede crear una especificaci\u00f3n que ning\u00fan modelo listado tiene realmente.<\/p>\n<h2>Leer lbf, kgf y N sin mezclar fuerza con masa<\/h2>\n<p><strong>lbf<\/strong> significa libra-fuerza; <strong>kgf<\/strong> significa kilogramo-fuerza. Ambas son unidades de fuerza. Un kilogramo (kg) por s\u00ed solo es una unidad de masa, por lo que reemplazar \u201ckgf\u201d por \u201ckg\u201d cambia el significado de la columna. El Instituto Nacional de Est\u00e1ndares y Tecnolog\u00eda (NIST) de EE. UU. enumera <strong>1 lbf \u2248 4.448222 N<\/strong> y <strong>1 kgf = 9.80665 N<\/strong>. <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\">Factores de conversi\u00f3n de fuerza de NIST SP 811<\/a>.<\/p>\n<p>Por ejemplo, <strong>50 lbf \u00d7 4.448222 \u2248 222 N<\/strong>. Para una especificaci\u00f3n controlada, solicite la base de prueba del modelo exacto.<\/p>\n<p>La unidad tambi\u00e9n importa cuando los n\u00fameros impresos parecen id\u00e9nticos. Un ejemplo ilustrativo <strong>10 lbf \u2248 44.5 N<\/strong>, mientras que <strong>10 kgf \u2248 98.1 N<\/strong>: los dos valores llamados \u201c10\u201d no son la misma fuerza. Convierta a una unidad com\u00fan antes de comparar tablas, pero conserve la entrada original y su unidad junto a su c\u00e1lculo. Los d\u00edgitos adicionales en el valor convertido no aumentan la precisi\u00f3n de la declaraci\u00f3n original del producto. Una conversi\u00f3n solo estandariza la unidad; no puede recuperar un m\u00e9todo de prueba faltante ni convertir una entrada de tracci\u00f3n en una carga continua admisible. <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\">Factores de conversi\u00f3n de fuerza NIST<\/a>.<\/p>\n<h2>La fuerza no es el esfuerzo del material<\/h2>\n<p>Un valor en lbf o kgf describe <strong>fuerza<\/strong>; una hoja de datos de material puede describir en su lugar el esfuerzo de <strong>tracci\u00f3n<\/strong> en megapascals (MPa). Estas son cantidades diferentes: <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-330\/sp-330-section-2\" target=\"_blank\" rel=\"noopener\">NIST&#8217;s SI table<\/a> gives the newton (N) for force and the pascal (Pa), equivalent to N\/m\u00b2, for stress. Strap width by itself is not a cross-sectional area. Dividing a listed tie force by width, or multiplying a material-stress value by width, therefore cannot produce a valid rating for a different tie. Keep the complete-tie declaration and any material property in separate fields until the relevant test basis is known.<\/p>\n<h2>What the tensile entry establishes<\/h2>\n<p>\u201cTensile strength\u201d needs a defined specimen and test condition. The International Electrotechnical Commission (IEC) defines <strong>la resistencia a la tracci\u00f3n del bucle<\/strong> for a cable tie with its lock engaged. Its IEC 62275:2022 public preview also says a loop tensile value does <strong>describe<\/strong> indicate long-term static load-bearing capability. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\">IEC 62275:2022 public preview, Sections 3.7 and 6.2.1<\/a>.<\/p>\n<p>YC lists <strong>\u201cTensile strength\u201d<\/strong> without a row-specific test method; the table alone cannot establish IEC testing. UL Solutions also distinguishes a locked tie\u2019s loop result from material strength and long-term support. <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\">UL cable-tie guidance<\/a>.<\/p>\n<p>The distinction is practical when two suppliers print similar force figures. The public IEC preview describes type-test specimens installed according to the manufacturer&#8217;s instructions; it also addresses stabilization of non-metallic samples, ambient conditions and a mandrel arrangement for mechanical tests. Those details show why the <strong>specimen, conditioning and test method<\/strong> matter to a comparison. They are requirements of the IEC method, not evidence that YOCL&#8217;s YC entries were obtained by that method. Ask whether a reported figure is a declared minimum loop result, another statistic or simply a catalogue heading before treating two numbers as comparable. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\">IEC 62275:2022 public preview, Section 5<\/a>.<\/p>\n<p>The table also cannot decide exposure suitability. Material, operating temperature, installation conditions and ultraviolet exposure require their own exact product information. For those separate choices, see <a href=\"https:\/\/yocl.com\/es\/nylon-vs-stainless-steel-cable-ties\/\">bridas de nylon frente a bridas de acero inoxidable<\/a> y <a href=\"https:\/\/yocl.com\/es\/uv-resistant-vs-standard-cable-ties\/\">UV-resistente frente a bridas est\u00e1ndar<\/a>.<\/p>\n<h2>Keep the exact-model record intact<\/h2>\n<p>When copying a chart entry into a drawing or purchase specification, keep the full model code, original units, listed dimensions, source page and retrieval date together. If a field is blank, write <strong>\u201cnot stated\u201d<\/strong>; a neighboring length or width does not fill it. Record your measured bundle diameter separately from the manufacturer&#8217;s maximum and from the evidence still needed for the application. For a force-sensitive use, that missing evidence may include the test method, specimen condition and approved service limits. This record makes an enquiry precise and prevents a later unit conversion or catalogue revision from hiding the original claim.<\/p>\n<p>Utilice el <a href=\"https:\/\/yocl.com\/es\/cable-ties-manufacturer\/\">gama de bridas YOCL<\/a> to compare the selected material and construction. Include the measured bundle diameter, intended environment and exact model when requesting its complete strength and test documentation.<\/p>\n<p><strong>Lecturas relacionadas:<\/strong> <a href=\"https:\/\/yocl.com\/es\/why-do-nylon-cable-ties-break\/\">troubleshooting broken nylon ties<\/a>.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li>YOCL EL\u00c9CTRICO, <a href=\"https:\/\/yocl.com\/es\/product\/yc-standard-nylon-cable-ties\/\"><em>YC Bridas de Nylon Est\u00e1ndar<\/em><\/a>, model table, checked 12 October 2026.<\/li>\n<li>UL Solutions, <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\"><em>Cable Ties and Cable Management<\/em><\/a>, bundling diameter, loop strength and application limits.<\/li>\n<li>National Institute of Standards and Technology, <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\"><em>Guide for the Use of the International System of Units (SI), SP 811, Appendix B.9: Force<\/em><\/a>, lbf and kgf conversion factors.<\/li>\n<li>National Institute of Standards and Technology, <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-330\/sp-330-section-2\" target=\"_blank\" rel=\"noopener\"><em>The International System of Units (SI), SP 330, Section 2<\/em><\/a>, SI units for force and stress.<\/li>\n<li>IEC, <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\"><em>IEC 62275:2022 \u2014 public preview<\/em><\/a>, Sections 3.7, 5.1\u20135.3, 5.9 and 6.2.1; consulted preview sections only.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Read each cable tie row as four separate specifications: length, actual strap width, maximum bundle diameter and declared tensile force. The model code alone cannot establish fit or load capacity. YOCL YC cable tie size and tensile strength chart Selected YC standard nylon rows; force columns show rounded catalogue equivalents, not working-load ratings. YC model [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3159,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[163],"tags":[],"class_list":["post-3160","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cable-ties-cable-management"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/comments?post=3160"}],"version-history":[{"count":0,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3160\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/3159"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=3160"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/categories?post=3160"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/tags?post=3160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}