{"id":3491,"date":"2026-11-17T03:24:34","date_gmt":"2026-11-17T03:24:34","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=1cd0ff666b000eee78a985037441d776f8a896fd5798439a3afc0287c89fca01"},"modified":"2026-11-17T03:24:34","modified_gmt":"2026-11-17T03:24:34","slug":"hook-terminals-explained","status":"publish","type":"post","link":"https:\/\/yocl.com\/es\/hook-terminals-explained\/","title":{"rendered":"Explicaci\u00f3n de los terminales de gancho: tama\u00f1os, rango de cable y crimpado"},"content":{"rendered":"<p><strong>Hook terminals<\/strong> are cold-compression crimp connectors whose contact blade forms an open side-entry C-curve instead of a closed ring or a two-prong fork, allowing the terminal to slide sideways onto a loosened bolt or stud and lock under the screw head when tightened. Across YOCL ELECTRIC&#8217;s 65 models, three wire groups pair with five bolt openings.<\/p>\n<p>Engineers specify a hook blade for one practical installation problem: a bolted connection point where the screw can be loosened a few turns for wiring or retrofit work, but cannot\u2014or should not\u2014be backed out completely. A closed ring terminal cannot be installed without removing the screw entirely, whereas an open C-hook slips onto the shaft from the side in crowded terminal rows or captive-screw blocks. To keep neighbouring topics distinct, general crimp-terminal structure belongs to <a href=\"https:\/\/yocl.com\/what-is-a-crimp-terminal\/\">what a crimp terminal is<\/a>, the choice between closed rings and two-prong forks belongs to <a href=\"https:\/\/yocl.com\/ring-vs-spade-terminals\/\">ring vs spade terminals<\/a>, and insulation-material properties belong to <a href=\"https:\/\/yocl.com\/pvc-vs-nylon-vs-non-insulated-crimp-terminals\/\">PVC vs nylon vs non-insulated crimp terminals<\/a>.<\/p>\n<h2>Open-Hook Geometry vs Closed Rings: The Side-Entry Trade-Off<\/h2>\n<p>An open hook blade combines side-entry installation access with partial wrap around the screw shaft, sitting mechanically between a closed ring and a straight fork. However, the same side throat that lets the hook slide onto a loosened stud also allows it to slip sideways if the fastener works loose.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/hook-terminals-explained-contact-shapes.webp\" width=\"1920\" height=\"1080\" alt=\"Technical contour comparison of closed ring, two-prong fork, and open C-hook crimp terminal contact shapes alongside an open hook terminal sliding sideways under a loosened captive terminal screw.\" \/><figcaption>Unlike a closed ring that requires full bolt removal, an open C-hook slides sideways onto a loosened captive screw and wraps partially around the shaft.<\/figcaption><\/figure>\n<p>Treat that open throat as a direct geometric consequence rather than a hidden performance rating:<\/p>\n<ul>\n<li><strong>Why the C-hook helps during service:<\/strong> Because the curved tip hooks around the back of the stud once seated, pulling straight backward along the wire axis draws the inner curve against the bolt shaft rather than sliding straight out like a parallel fork.<\/li>\n<li><strong>Why it is not a captive joint:<\/strong> If thermal cycling or improper tightening leaves the screw head loose, sideways movement toward the open throat can still unhook the blade completely\u2014something a closed ring physically prevents as long as the stud remains in place.<\/li>\n<li><strong>Field selection rule:<\/strong> Specify a closed ring whenever the bolt can be removed and the wire must stay captive on the stud; specify a hook terminal where captive hardware or tight panel access demands side entry and screw clamping tightness is verified during assembly.<\/li>\n<\/ul>\n<h2>Hook Terminals Size System: Model Codes, Bolt Openings, and Full Charts<\/h2>\n<p>Selecting <strong>hook terminals<\/strong> accurately starts with decoding YOCL&#8217;s shared model-code system and three-group dimensional ladder across all 65 catalogue SKUs. Every model code pairs a conductor-range prefix with a nominal bolt-size suffix\u2014and the nominal suffix after the dash is never equal to the measured hook opening d2.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/hook-terminals-explained-dimension-guide.webp\" width=\"1920\" height=\"1080\" alt=\"Orthographic dimension guide for hook terminals showing outer hook width B, bolt opening d2, neck-to-center distance F, barrel length E, overall length L, bare barrel diameters d and D, single-crimp barrel D1, and double-crimp barrel D2.\" \/><figcaption>Dimension letters shared across YOCL hook-terminal drawings: d2 is the actual bolt opening, B and F govern head clearance, E is barrel length, L is overall length, and D1 versus D2 distinguish single-crimp and double-crimp barrels.<\/figcaption><\/figure>\n<h3>Decoding the Shared Conductor and Bolt Ladder<\/h3>\n<p>All three YOCL families\u2014bare copper <strong>HNB<\/strong>, nylon-insulated <strong>HNY\/HNYD<\/strong>, and PVC-insulated <strong>HV\/HVD<\/strong>\u2014use the exact same model-code syntax: <strong>[Series] [Group]-[Bolt Code]<\/strong>. For example, <strong>HNB 2-5<\/strong> identifies series HNB, conductor group <strong>2<\/strong> (1.5\u20132.5 mm\u00b2), and bolt code <strong>5<\/strong> (#10 bolt).<\/p>\n<ul>\n<li><strong>Three shared conductor groups:<\/strong> Group <strong>1.25<\/strong> covers <strong>0.5\u20131.5 mm\u00b2<\/strong>; Group <strong>2<\/strong> covers <strong>1.5\u20132.5 mm\u00b2<\/strong>; Group <strong>5.5<\/strong> covers <strong>4\u20136 mm\u00b2<\/strong>. The insulated HNY\/HNYD and HV\/HVD pages also print the equivalent <strong>AWG 22\u201316<\/strong>, <strong>AWG 16\u201314<\/strong>, and <strong>AWG 12\u201310<\/strong> ranges and color-code the sleeves <strong>Red<\/strong> (1.25), <strong>Blue<\/strong> (2), and <strong>Yellow<\/strong> (5.5), whereas the HNB page lists mm\u00b2 only. Copper contact thickness across all three families is <strong>0.7 mm<\/strong> (group 1.25), <strong>0.8 mm<\/strong> (group 2), and <strong>1.0 mm<\/strong> (group 5.5).<\/li>\n<li><strong>Catalogue Imax label boundary:<\/strong> Across all three families, the group tables list <strong>Imax = 19 A<\/strong> (group 1.25), <strong>27 A<\/strong> (group 2), and <strong>48 A<\/strong> (group 5.5). As stated on YOCL&#8217;s product pages, Imax is the catalogue&#8217;s maximum-current label for the conductor group and <strong>test or installation conditions are not provided<\/strong>\u2014never treat Imax as an installed circuit ampacity.<\/li>\n<li><strong>Nominal bolt code vs actual opening d2:<\/strong> Each family lists 13 models per crimp style (4 in group 1.25, 4 in group 2, and 5 in group 5.5, where the <strong>5\/16<\/strong> bolt size exists only in group 5.5). The number after the dash (<strong>3.5<\/strong>, <strong>4<\/strong>, <strong>5<\/strong>, <strong>6<\/strong>, <strong>8<\/strong>) is the nominal screw code, while <strong>d2<\/strong> is the actual clearance opening in millimeters:<\/li>\n<li>Suffix <strong>-3.5<\/strong> (#6 US bolt) \u2192 actual opening <strong>d2 = 3.7 mm<\/strong><\/li>\n<li>Suffix <strong>-4<\/strong> (#8 US bolt) \u2192 actual opening <strong>d2 = 4.3 mm<\/strong><\/li>\n<li>Suffix <strong>-5<\/strong> (#10 US bolt) \u2192 actual opening <strong>d2 = 5.3 mm<\/strong><\/li>\n<li>Suffix <strong>-6<\/strong> (1\/4 US bolt) \u2192 actual opening <strong>d2 = 6.5 mm<\/strong><\/li>\n<li>Suffix <strong>-8<\/strong> (5\/16 US bolt, group 5.5 only) \u2192 actual opening <strong>d2 = 8.5 mm<\/strong><\/li>\n<li><strong>Selection sequence:<\/strong> Match wire cross-section to the <strong>conductor group<\/strong> first, match the stud or screw size to <strong>d2<\/strong> second, and check <strong>B<\/strong> (outer hook width), <strong>F<\/strong> (barrel top to bolt center), and <strong>L<\/strong> (overall length) against the barrier walls around the terminal post\u2014because a hook slides on from the side, it requires lateral clearance beside the screw. (For tab-style disconnects that use a different sizing system, see <a href=\"https:\/\/yocl.com\/quick-disconnect-terminal-size-chart\/\">the quick-disconnect terminal size chart<\/a>.)<\/li>\n<\/ul>\n<h3>Family 1: HNB Non-Insulated Hook Terminals (TO Type)<\/h3>\n<p>YOCL&#8217;s <a href=\"https:\/\/yocl.com\/product\/hnb-to-non-insulated-hook-terminals\/\">HNB non-insulated hook terminals (TO type)<\/a> are uninsulated copper terminals across 13 models, providing the shortest overall length L (15.7\u201327.0 mm) and bare barrels for direct visual inspection or post-crimp heat-shrink tubing.<\/p>\n<p>Within each conductor group, copper thickness, barrel length <strong>E<\/strong>, barrel outer diameter <strong>D<\/strong>, and barrel inner diameter <strong>d<\/strong> are shared: Group <strong>1.25<\/strong> (0.5\u20131.5 mm\u00b2, Imax 19 A without test\/installation conditions stated) has thickness <strong>0.7 mm<\/strong>, <strong>E = 4.8 mm<\/strong>, <strong>D = 3.4 mm<\/strong>, <strong>d = 1.7 mm<\/strong>; Group <strong>2<\/strong> (1.5\u20132.5 mm\u00b2, Imax 27 A, no conditions stated) has thickness <strong>0.8 mm<\/strong>, <strong>E = 4.8 mm<\/strong>, <strong>D = 4.1 mm<\/strong>, <strong>d = 2.3 mm<\/strong>; Group <strong>5.5<\/strong> (4\u20136 mm\u00b2, Imax 48 A, no conditions stated) has thickness <strong>1.0 mm<\/strong>, <strong>E = 6.0 mm<\/strong>, <strong>D = 5.6 mm<\/strong>, <strong>d = 3.4 mm<\/strong>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Section (mm\u00b2)<\/th>\n<th>Bolt<\/th>\n<th>d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D (mm)<\/th>\n<th>d (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>HNB 1.25-3.5<\/strong><\/td>\n<td>0.5\u20131.5<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>15.8<\/td>\n<td>4.8<\/td>\n<td>3.4<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 1.25-4<\/strong><\/td>\n<td>0.5\u20131.5<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>15.8<\/td>\n<td>4.8<\/td>\n<td>3.4<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 1.25-5<\/strong><\/td>\n<td>0.5\u20131.5<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>15.8<\/td>\n<td>4.8<\/td>\n<td>3.4<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 1.25-6<\/strong><\/td>\n<td>0.5\u20131.5<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>11.6<\/td>\n<td>11.0<\/td>\n<td>21.8<\/td>\n<td>4.8<\/td>\n<td>3.4<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 2-3.5<\/strong><\/td>\n<td>1.5\u20132.5<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>16.8<\/td>\n<td>4.8<\/td>\n<td>4.1<\/td>\n<td>2.3<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 2-4<\/strong><\/td>\n<td>1.5\u20132.5<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>16.8<\/td>\n<td>4.8<\/td>\n<td>4.1<\/td>\n<td>2.3<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 2-5<\/strong><\/td>\n<td>1.5\u20132.5<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>7.3<\/td>\n<td>16.8<\/td>\n<td>4.8<\/td>\n<td>4.1<\/td>\n<td>2.3<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 2-6<\/strong><\/td>\n<td>1.5\u20132.5<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>21.8<\/td>\n<td>4.8<\/td>\n<td>4.1<\/td>\n<td>2.3<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 5.5-3.5<\/strong><\/td>\n<td>4\u20136<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>7.2<\/td>\n<td>6.1<\/td>\n<td>15.7<\/td>\n<td>6.0<\/td>\n<td>5.6<\/td>\n<td>3.4<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 5.5-4<\/strong><\/td>\n<td>4\u20136<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>19.8<\/td>\n<td>6.0<\/td>\n<td>5.6<\/td>\n<td>3.4<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 5.5-5<\/strong><\/td>\n<td>4\u20136<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>19.8<\/td>\n<td>6.0<\/td>\n<td>5.6<\/td>\n<td>3.4<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 5.5-6<\/strong><\/td>\n<td>4\u20136<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>10.3<\/td>\n<td>22.5<\/td>\n<td>6.0<\/td>\n<td>5.6<\/td>\n<td>3.4<\/td>\n<\/tr>\n<tr>\n<td><strong>HNB 5.5-8<\/strong><\/td>\n<td>4\u20136<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>15.0<\/td>\n<td>13.5<\/td>\n<td>27.0<\/td>\n<td>6.0<\/td>\n<td>5.6<\/td>\n<td>3.4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Selection Rule:<\/strong> Choose HNB bare copper models when minimal overall length L (15.7\u201327.0 mm) is required in tight spaces or when external heat-shrink tubing will be applied after crimping; switch to HNY\/HNYD or HV\/HVD whenever pre-insulated color-coded barrels are required.<\/p>\n<h3>Family 2: HNY (Single Crimp) and HNYD (Double Crimp) Nylon Hook Terminals<\/h3>\n<p>YOCL&#8217;s <a href=\"https:\/\/yocl.com\/product\/hny-hnyd-nylon-hook-terminals\/\">HNY\/HNYD nylon hook terminals<\/a> pair a copper contact with a nylon insulating sleeve across 13 matched single-crimp (<strong>HNY<\/strong>) and double-crimp (<strong>HNYD<\/strong>) rows (26 models). For this nylon family\u2014and this family only\u2014the product page states <strong>600 V<\/strong> and <strong>105 \u00b0C<\/strong> across all three size groups.<\/p>\n<p>Group parameters pair <strong>Red<\/strong> (group 1.25: 0.5\u20131.5 mm\u00b2 \/ AWG 22\u201316, thickness 0.7 mm, catalogue Imax 19 A without test\/installation conditions), <strong>Blue<\/strong> (group 2: 1.5\u20132.5 mm\u00b2 \/ AWG 16\u201314, thickness 0.8 mm, Imax 27 A, no conditions stated), and <strong>Yellow<\/strong> (group 5.5: 4\u20136 mm\u00b2 \/ AWG 12\u201310, thickness 1.0 mm, Imax 48 A, no conditions stated).<\/p>\n<table>\n<thead>\n<tr>\n<th>HNY (Single)<\/th>\n<th>HNYD (Double)<\/th>\n<th>Color<\/th>\n<th>Bolt<\/th>\n<th>d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D1 (mm)<\/th>\n<th>D2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>HNY 1.25-3.5<\/strong><\/td>\n<td><strong>HNYD 1.25-3.5<\/strong><\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>22.0<\/td>\n<td>11.0<\/td>\n<td>4.3<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 1.25-4<\/strong><\/td>\n<td><strong>HNYD 1.25-4<\/strong><\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>22.0<\/td>\n<td>11.0<\/td>\n<td>4.3<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 1.25-5<\/strong><\/td>\n<td><strong>HNYD 1.25-5<\/strong><\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>22.0<\/td>\n<td>11.0<\/td>\n<td>4.3<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 1.25-6<\/strong><\/td>\n<td><strong>HNYD 1.25-6<\/strong><\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>11.6<\/td>\n<td>11.0<\/td>\n<td>28.0<\/td>\n<td>11.0<\/td>\n<td>4.3<\/td>\n<td>4.8<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 2-3.5<\/strong><\/td>\n<td><strong>HNYD 2-3.5<\/strong><\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>23.0<\/td>\n<td>11.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 2-4<\/strong><\/td>\n<td><strong>HNYD 2-4<\/strong><\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>23.0<\/td>\n<td>11.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 2-5<\/strong><\/td>\n<td><strong>HNYD 2-5<\/strong><\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>7.3<\/td>\n<td>23.0<\/td>\n<td>11.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 2-6<\/strong><\/td>\n<td><strong>HNYD 2-6<\/strong><\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>28.0<\/td>\n<td>11.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 5.5-3.5<\/strong><\/td>\n<td><strong>HNYD 5.5-3.5<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>7.2<\/td>\n<td>6.1<\/td>\n<td>23.7<\/td>\n<td>14.0<\/td>\n<td>6.9<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 5.5-4<\/strong><\/td>\n<td><strong>HNYD 5.5-4<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>27.8<\/td>\n<td>14.0<\/td>\n<td>6.9<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 5.5-5<\/strong><\/td>\n<td><strong>HNYD 5.5-5<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>27.8<\/td>\n<td>14.0<\/td>\n<td>6.9<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 5.5-6<\/strong><\/td>\n<td><strong>HNYD 5.5-6<\/strong><\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>10.3<\/td>\n<td>30.5<\/td>\n<td>14.0<\/td>\n<td>6.9<\/td>\n<td>7.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HNY 5.5-8<\/strong><\/td>\n<td><strong>HNYD 5.5-8<\/strong><\/td>\n<td>Yellow<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>15.0<\/td>\n<td>13.5<\/td>\n<td>35.0<\/td>\n<td>14.0<\/td>\n<td>6.9<\/td>\n<td>7.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Selection Rule:<\/strong> Choose HNY\/HNYD when the specification requires nylon insulation with stated 600 V and 105 \u00b0C group parameters; select HNYD (D2 = 4.8 \/ 5.2 \/ 7.2 mm) over HNY (D1 = 4.3 \/ 4.9 \/ 6.9 mm) when a double-crimp barrel over the wire insulation is needed.<\/p>\n<h3>Family 3: HV (Single Crimp) and HVD (Double Crimp) PVC Pre-Insulated Hook Terminals<\/h3>\n<p>YOCL&#8217;s <a href=\"https:\/\/yocl.com\/product\/hv-hvd-pre-insulated-hook-terminals\/\">HV\/HVD pre-insulated hook terminals<\/a> pair a copper contact with a PVC sleeve across 13 matched pairs (26 models), where <strong>HVD<\/strong> incorporates an additional copper tube with sleeve described on the source page as double pressure.<\/p>\n<p>Group wire ranges (<strong>Red<\/strong> 0.5\u20131.5 mm\u00b2 \/ AWG 22\u201316; <strong>Blue<\/strong> 1.5\u20132.5 mm\u00b2 \/ AWG 16\u201314; <strong>Yellow<\/strong> 4\u20136 mm\u00b2 \/ AWG 12\u201310), copper thicknesses (0.7 \/ 0.8 \/ 1.0 mm), and catalogue Imax labels (19 A \/ 27 A \/ 48 A, without test or installation conditions stated) match the shared ladder, while the HV\/HVD page states <strong>no<\/strong> voltage or temperature rating.<\/p>\n<table>\n<thead>\n<tr>\n<th>HV (Single)<\/th>\n<th>HVD (Double)<\/th>\n<th>Color<\/th>\n<th>Bolt<\/th>\n<th>d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<th>E (mm)<\/th>\n<th>D1 (mm)<\/th>\n<th>D2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>HV 1.25-3.5<\/strong><\/td>\n<td><strong>HVD 1.25-3.5<\/strong><\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 1.25-4<\/strong><\/td>\n<td><strong>HVD 1.25-4<\/strong><\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 1.25-5<\/strong><\/td>\n<td><strong>HVD 1.25-5<\/strong><\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 1.25-6<\/strong><\/td>\n<td><strong>HVD 1.25-6<\/strong><\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>11.6<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 2-3.5<\/strong><\/td>\n<td><strong>HVD 2-3.5<\/strong><\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>22.0<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 2-4<\/strong><\/td>\n<td><strong>HVD 2-4<\/strong><\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>22.0<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 2-5<\/strong><\/td>\n<td><strong>HVD 2-5<\/strong><\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>7.3<\/td>\n<td>22.0<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 2-6<\/strong><\/td>\n<td><strong>HVD 2-6<\/strong><\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 5.5-3.5<\/strong><\/td>\n<td><strong>HVD 5.5-3.5<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>7.2<\/td>\n<td>6.1<\/td>\n<td>22.7<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 5.5-4<\/strong><\/td>\n<td><strong>HVD 5.5-4<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>26.8<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 5.5-5<\/strong><\/td>\n<td><strong>HVD 5.5-5<\/strong><\/td>\n<td>Yellow<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>9.5<\/td>\n<td>26.8<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 5.5-6<\/strong><\/td>\n<td><strong>HVD 5.5-6<\/strong><\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>10.3<\/td>\n<td>29.5<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<tr>\n<td><strong>HV 5.5-8<\/strong><\/td>\n<td><strong>HVD 5.5-8<\/strong><\/td>\n<td>Yellow<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>15.0<\/td>\n<td>13.5<\/td>\n<td>34.0<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Selection Rule:<\/strong> Choose HV (single crimp, D1 = 4.3 \/ 4.9 \/ 6.7 mm) or HVD (double-pressure copper tube + PVC sleeve, D2 = 4.5 \/ 5.2 \/ 7.0 mm) when standard PVC pre-insulated hook terminals with 1.0 mm shorter sleeve lengths E (10.0 \/ 10.0 \/ 13.0 mm) and overall lengths L (21.0\u201334.0 mm) fit the panel layout.<\/p>\n<h2>Three Hook-Terminal Families on One Shared Dimensional Ladder<\/h2>\n<p>Comparing HNB, HNY\/HNYD, and HV\/HVD side by side shows that all 65 models share one identical contact-blade ladder\u2014every matching suffix has the exact same d2 opening, outer hook width B, neck length F, and copper thickness. Only the barrel insulation, sleeve length E, and overall length L change.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/hook-terminals-explained-three-families.webp\" width=\"1920\" height=\"1080\" alt=\"Catalogue studio comparison of YOCL HNB non-insulated bare copper hook terminal, HNY\/HNYD nylon-insulated hook terminal, and HV\/HVD PVC pre-insulated hook terminal.\" \/><figcaption>All three YOCL hook-terminal families share the same copper contact thickness and d2\/B\/F blade dimensions within each size group, differing only in barrel insulation and E\/L sleeve lengths.<\/figcaption><\/figure>\n<p>Because the hook blade itself never changes between families for a given model suffix, switching between bare, nylon, and PVC versions affects only the wire-entry barrel:<\/p>\n<ul>\n<li><strong>HNB (TO type):<\/strong> Uninsulated copper barrel with <strong>E = 4.8 \/ 4.8 \/ 6.0 mm<\/strong> and the shortest overall lengths (<strong>L = 15.7\u201327.0 mm<\/strong>).<\/li>\n<li><strong>HNY and HNYD:<\/strong> Nylon-insulated single-crimp and double-crimp barrels with <strong>E = 11.0 \/ 11.0 \/ 14.0 mm<\/strong>, <strong>L = 22.0\u201335.0 mm<\/strong>, and stated <strong>600 V \/ 105 \u00b0C<\/strong> group ratings.<\/li>\n<li><strong>HV and HVD:<\/strong> PVC pre-insulated single-crimp and double-pressure barrels with <strong>E = 10.0 \/ 10.0 \/ 13.0 mm<\/strong> and <strong>L = 21.0\u201334.0 mm<\/strong> (each 1.0 mm shorter in E and L than the corresponding HNY\/HNYD row). For how PVC, nylon, and non-insulated sleeves compare in application, see <a href=\"https:\/\/yocl.com\/pvc-vs-nylon-vs-non-insulated-crimp-terminals\/\">PVC vs nylon vs non-insulated crimp terminals<\/a>.<\/li>\n<\/ul>\n<h2>Single Crimp vs Double Crimp Barrels: D1, D2, and Die Matching<\/h2>\n<p>In both insulated families, the single-crimp versions (HNY, HV) and double-crimp versions (HNYD, HVD) differ in barrel construction and outer entry diameter: every double-crimp model carries a larger barrel diameter <strong>D2 &gt; D1<\/strong>, providing a second compression zone over the wire insulation alongside the conductor crimp.<\/p>\n<p>Look at how the published barrel diameters step up from <strong>D1<\/strong> (single crimp) to <strong>D2<\/strong> (double crimp) across all three wire groups:<\/p>\n<ul>\n<li><strong>Group 1.25 (Red, 0.5\u20131.5 mm\u00b2):<\/strong> HNY <strong>D1 = 4.3 mm<\/strong> vs HNYD <strong>D2 = 4.8 mm<\/strong>; HV <strong>D1 = 4.3 mm<\/strong> vs HVD <strong>D2 = 4.5 mm<\/strong>.<\/li>\n<li><strong>Group 2 (Blue, 1.5\u20132.5 mm\u00b2):<\/strong> HNY <strong>D1 = 4.9 mm<\/strong> vs HNYD <strong>D2 = 5.2 mm<\/strong>; HV <strong>D1 = 4.9 mm<\/strong> vs HVD <strong>D2 = 5.2 mm<\/strong>.<\/li>\n<li><strong>Group 5.5 (Yellow, 4\u20136 mm\u00b2):<\/strong> HNY <strong>D1 = 6.9 mm<\/strong> vs HNYD <strong>D2 = 7.2 mm<\/strong>; HV <strong>D1 = 6.7 mm<\/strong> vs HVD <strong>D2 = 7.0 mm<\/strong>.<\/li>\n<\/ul>\n<p>As the HV\/HVD specification page notes, the <strong>HVD<\/strong> double-crimp barrel contains an additional internal copper tube inside the sleeve\u2014referred to as a double-pressure construction\u2014so closing the crimping tool compresses the primary copper barrel onto the stripped conductor strands while the rear section grips the wire insulation jacket. Match the crimping die cavity strictly to the chosen construction (<strong>D1<\/strong> vs <strong>D2<\/strong>): crimping a larger <strong>D2<\/strong> double-crimp barrel in a narrow single-crimp die setting crushes the sleeve unevenly and damages the insulation entry.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Should I choose a hook terminal or a ring terminal?<\/h3>\n<p>Access to the fastener decides. Choose a closed ring terminal whenever the screw or nut can be removed completely and the wire must remain captive on the stud. Choose a hook terminal when captive hardware or tight spacing allows loosening the screw only a few turns and clamp tightness is verified; see <a href=\"https:\/\/yocl.com\/ring-vs-spade-terminals\/\">ring vs spade terminals<\/a>.<\/p>\n<h3>What does the number after the dash mean in a hook terminal code?<\/h3>\n<p>The number after the dash (<strong>3.5<\/strong>, <strong>4<\/strong>, <strong>5<\/strong>, <strong>6<\/strong>, or <strong>8<\/strong>) is the nominal screw code, not the measured hook opening. Always read the actual clearance opening <strong>d2<\/strong> from the table: code <strong>3.5<\/strong> (#6 bolt) has <strong>d2 = 3.7 mm<\/strong>, <strong>4<\/strong> (#8) has <strong>4.3 mm<\/strong>, <strong>5<\/strong> (#10) has <strong>5.3 mm<\/strong>, <strong>6<\/strong> (1\/4) has <strong>6.5 mm<\/strong>, and <strong>8<\/strong> (5\/16) has <strong>8.5 mm<\/strong>.<\/p>\n<h3>Can a hook terminal go on a bolt one size larger than its chart row?<\/h3>\n<p>No. The hook opening <strong>d2<\/strong> is sized to clear its designated bolt shaft (#6 through 5\/16) and seat around the stud center. Forcing a smaller hook onto the next bolt size up prevents the C-curve from seating around the shaft, while using an oversized hook leaves minimal contact area under the screw head and lets the blade slip off easily.<\/p>\n<h3>Should I specify single crimp (HNY \/ HV) or double crimp (HNYD \/ HVD)?<\/h3>\n<p>Specify single crimp (<strong>HNY<\/strong> or <strong>HV<\/strong>, barrel diameter <strong>D1<\/strong>) when standard conductor-only compression in a flared insulating skirt fits your crimping tool; specify double crimp (<strong>HNYD<\/strong> or <strong>HVD<\/strong>, larger barrel diameter <strong>D2 &gt; D1<\/strong> with an inner copper sleeve on HVD) when you need a second grip section over the wire insulation and have a matching double-crimp die.<\/p>\n<h2>References<\/h2>\n<ul>\n<li><strong>YOCL ELECTRIC Product Information<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/product\/hnb-to-non-insulated-hook-terminals\/\">HNB Non-Insulated Hook Terminals (TO Type)<\/a>: bare copper specifications, group Imax labels, and 13-model dimensional table.<\/li>\n<li><strong>YOCL ELECTRIC Product Information<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/product\/hny-hnyd-nylon-hook-terminals\/\">HNY\/HNYD Nylon Hook Terminals (Single and Double Crimp)<\/a>: nylon-insulated single-crimp (D1) and double-crimp (D2) specifications, 600 V and 105 \u00b0C group ratings, and 13 paired model rows.<\/li>\n<li><strong>YOCL ELECTRIC Product Information<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/product\/hv-hvd-pre-insulated-hook-terminals\/\">HV\/HVD Pre-Insulated Hook Terminals<\/a>: PVC-insulated single-crimp (HV) and double-pressure additional-copper-tube (HVD) specifications and 13 paired model rows.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Hook terminals are cold-compression crimp connectors whose contact blade forms an open side-entry C-curve instead of a closed ring or a two-prong fork, allowing the terminal to slide sideways onto a loosened bolt or stud and lock under the screw head when tightened. Across YOCL ELECTRIC&#8217;s 65 models, three wire groups pair with five bolt [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3490,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-3491","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/comments?post=3491"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3491\/revisions"}],"predecessor-version":[{"id":3492,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3491\/revisions\/3492"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/3490"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=3491"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/categories?post=3491"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/tags?post=3491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}