{"id":3497,"date":"2026-11-17T07:54:31","date_gmt":"2026-11-17T07:54:31","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=edace9f05519d0d8565406f20f3b92f0a6d1007a6d557f5f45cc08435f180623"},"modified":"2026-11-17T07:54:31","modified_gmt":"2026-11-17T07:54:31","slug":"two-hole-cable-lugs","status":"publish","type":"post","link":"https:\/\/yocl.com\/es\/two-hole-cable-lugs\/","title":{"rendered":"Terminales de cable de dos agujeros: distancia entre agujeros, tama\u00f1os y cu\u00e1ndo un solo tornillo no es suficiente"},"content":{"rendered":"<p><strong>Terminales de cable de dos agujeros<\/strong> son terminales tubulares de compresi\u00f3n fabricados con un cuerpo para el conductor y una pala de montaje plana extendida perforada con dos agujeros para tornillos en l\u00ednea, lo que bloquea la orientaci\u00f3n angular de la pala en terminales de equipos y barras colectoras de dos esp\u00e1rragos. En las series de cobre DT-2 y aluminio DL-2 de YOCL ELECTRIC, los modelos 27 cubren de 16 a 630 mm\u00b2.<\/p>\n<p>Especificar una pala de dos agujeros requiere algo m\u00e1s que hacer coincidir la secci\u00f3n transversal del cable y el di\u00e1metro del tornillo. Debido a que dos tornillos pasan a trav\u00e9s de la misma pala r\u00edgida, el terminal solo encaja en el terminal del equipo cuando tanto el di\u00e1metro del agujero de montaje <strong>\u03a6<\/strong> como la distancia entre centros de los agujeros <strong>L3<\/strong> coinciden simult\u00e1neamente con el patr\u00f3n de agujeros del terminal. Para mantener distintos los temas relacionados, las dimensiones de los terminales de un solo agujero y generales pertenecen a <a href=\"https:\/\/yocl.com\/es\/cable-lug-size-chart\/\">la tabla de tama\u00f1os de terminales de cable<\/a>, mientras que la correspondencia entre los metales del conductor y del terminal pertenece a <a href=\"https:\/\/yocl.com\/es\/copper-vs-aluminium-vs-bimetallic-cable-lugs\/\">terminales de cobre frente a aluminio frente a bimet\u00e1licos<\/a>, la preparaci\u00f3n de la uni\u00f3n para barriles de aluminio pertenece a <a href=\"https:\/\/yocl.com\/es\/aluminium-cable-lug-antioxidant-compound\/\">compuesto antioxidante para terminales de aluminio<\/a>, y la herramienta de compresi\u00f3n pertenece a <a href=\"https:\/\/yocl.com\/es\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">c\u00f3mo combinar terminales de cable, matrices de crimpado y conductores<\/a>.<\/p>\n<h2>Qu\u00e9 es un terminal de dos agujeros: bloqueo de orientaci\u00f3n frente a rotaci\u00f3n de un solo tornillo<\/h2>\n<p>Un terminal de dos agujeros combina un barril conductor cil\u00edndrico con una pala plana alargada que lleva dos agujeros de montaje en l\u00ednea. El segundo agujero no es un punto de fijaci\u00f3n de repuesto: apretar dos tornillos a lo largo de la l\u00ednea central de la pala fija la orientaci\u00f3n de la misma y elimina la libertad de rotaci\u00f3n alrededor del eje del tornillo.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/two-hole-cable-lugs-palm-comparison.webp\" width=\"1920\" height=\"1080\" alt=\"Conceptual outline comparison of a single-hole cable lug palm and a two-hole cable lug palm marked with hole diameter \u03a6 and centre-to-centre hole spacing L3.\" \/><figcaption>Una pala de un solo agujero est\u00e1 fijada en un eje y puede pivotar alrededor de su tornillo, mientras que una pala de dos agujeros fijada en dos centros separados por L3 bloquea la orientaci\u00f3n del terminal.<\/figcaption><\/figure>\n<p>Desde un punto de vista geom\u00e9trico y de instalaci\u00f3n, comparar una pala de un solo tornillo frente a una de dos tornillos explica por qu\u00e9 se utilizan dos puntos de fijaci\u00f3n en terminaciones m\u00e1s grandes:<\/p>\n<ul>\n<li><strong>Por qu\u00e9 una pala de un solo tornillo puede girar:<\/strong> Un \u00fanico orificio de montaje restringe el movimiento a trav\u00e9s de la cara de la pala, pero deja un grado de libertad de rotaci\u00f3n alrededor del eje del tornillo. Debido a la rigidez a la flexi\u00f3n de un cable de alimentaci\u00f3n pesado, a la carga lateral durante la instalaci\u00f3n o a un tornillo que ha perdido fuerza de apriete, una pala de un solo tornillo puede pivotar lateralmente alrededor de su esp\u00e1rrago.<\/li>\n<li><strong>C\u00f3mo dos tornillos eliminan la libertad de rotaci\u00f3n:<\/strong> A\u00f1adir un segundo orificio de montaje a una distancia entre centros <strong>L3<\/strong> establece una restricci\u00f3n de l\u00ednea de dos puntos. Con ambos tornillos instalados, la pala no puede girar hacia barras de fase adyacentes, paredes de envolventes o terminales vecinos.<\/li>\n<li><strong>Solo geometr\u00eda y pr\u00e1ctica de instalaci\u00f3n:<\/strong> Las p\u00e1ginas de producto de YOCL indican la configuraci\u00f3n estructural (un cuerpo para el conductor, dos orificios de montaje y la conexi\u00f3n prevista de un conductor de cobre o aluminio a un terminal de equipo el\u00e9ctrico) sin publicar datos comparativos de vibraci\u00f3n, extracci\u00f3n, par de apriete o corriente. Considere la pala de dos orificios estrictamente como una geometr\u00eda de fijaci\u00f3n de orientaci\u00f3n y adaptaci\u00f3n de terminales.<\/li>\n<\/ul>\n<h2>La diferencia en la especificaci\u00f3n: coincidencia tanto del di\u00e1metro del orificio (\u03a6) como de la distancia entre centros (L3)<\/h2>\n<p>Mientras que la pala de un terminal de un solo orificio se especifica mediante una \u00fanica dimensi\u00f3n de ajuste (el di\u00e1metro de su orificio de montaje), la pala de un terminal de dos orificios se especifica mediante dos dimensiones de ajuste obligatorias a la vez: el di\u00e1metro de cada orificio <strong>\u03a6<\/strong> y la distancia entre centros de los orificios <strong>L3<\/strong>. Ambos valores deben coincidir con el patr\u00f3n de orificios del terminal del equipo.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/two-hole-cable-lugs-dimension-guide.webp\" width=\"1920\" height=\"1080\" alt=\"Orthographic engineering dimension guide for YOCL two-hole cable lugs showing hole diameter \u03a6, centre-to-centre hole spacing L3, palm width B, overall length L, lengths L1 and L2, barrel outer diameter D, and barrel inner diameter d.\" \/><figcaption>Definiciones de campo de los planos DT-2 y DL-2 de YOCL: \u03a6 es el di\u00e1metro de cada orificio de montaje, L3 es la distancia entre centros de los dos orificios, B es el ancho de la pala, D y d son los di\u00e1metros exterior e interior del cuerpo, y L, L1 y L2 siguen los planos de la p\u00e1gina.<\/figcaption><\/figure>\n<p>Cuatro reglas rigen toda especificaci\u00f3n de terminal de dos orificios:<\/p>\n<ul>\n<li><strong>Definiciones de campo del plano:<\/strong> En ambas p\u00e1ginas de producto de YOCL, <strong>\u03a6<\/strong> es el di\u00e1metro de cada orificio de montaje, <strong>L3<\/strong> es la distancia entre centros de los dos orificios, <strong>D<\/strong> es el di\u00e1metro exterior del tubo, <strong>d<\/strong> es el di\u00e1metro interior del tubo, <strong>B<\/strong> es la anchura de la pala, y <strong>L<\/strong>, <strong>L1<\/strong>, y <strong>L2<\/strong> follow the overall, barrel, and palm length callouts on the page drawings. Every dimension is in millimetres, and the model suffix is the conductor size in mm\u00b2.<\/li>\n<li><strong>L3 steps in six discrete increments:<\/strong> Across both the DT-2 and DL-2 ranges, <strong>L3<\/strong> is not continuous and is not fixed at one universal pitch. As conductor cross-section grows, <strong>L3<\/strong> steps through <strong>20 mm<\/strong>, <strong>25 mm<\/strong>, <strong>30 mm<\/strong>, <strong>35 mm<\/strong>, <strong>40 mm<\/strong>, y <strong>45 mm<\/strong>.<\/li>\n<li><strong>A 5 mm L3 mismatch does not fit at all:<\/strong> If a lug&#8217;s hole diameter <strong>\u03a6<\/strong> matches the terminal studs but its centre spacing <strong>L3<\/strong> is even 5 mm off\u2014such as a 35 mm spacing palm held against a 40 mm spacing busbar\u2014the second bolt cannot enter the hole.<\/li>\n<li><strong>Order by the terminal pattern, not by conductor size alone:<\/strong> A lug with the wrong <strong>L3<\/strong> cannot be &#8220;made to fit&#8221; without re-drilling or slotting the palm, which modifies the lug outside the product as supplied. Always check the equipment terminal&#8217;s hole diameter and centre-to-centre spacing before ordering.<\/li>\n<\/ul>\n<h2>Two-Hole Cable Lugs Size Charts: YOCL DT-2 Copper and DL-2 Aluminium Series<\/h2>\n<p>Especificaci\u00f3n <strong>two-hole cable lugs<\/strong> from YOCL ELECTRIC requires checking the exact table for your conductor material: <strong>DT-2<\/strong> for copper conductors (13 models, 25\u2013630 mm\u00b2) and <strong>DL-2<\/strong> for aluminium conductors (14 models, 16\u2013630 mm\u00b2). Never merge the two charts or use one material&#8217;s row for the other.<\/p>\n<h3>Table A: DT-2 Two-Hole Copper Cable Lugs (25\u2013630 mm\u00b2, 13 Models)<\/h3>\n<p>de YOCL <a href=\"https:\/\/yocl.com\/es\/product\/dt-2-two-hole-copper-cable-lugs\/\">DT-2 two-hole copper cable lugs<\/a> are copper compression lugs with one conductor barrel and two mounting holes, designed to connect copper conductors (25\u2013630 mm\u00b2) to electrical equipment terminals.<\/p>\n<p>Across the 13 DT-2 models, hole diameter <strong>\u03a6<\/strong> steps through <strong>8.5<\/strong>, <strong>10.5<\/strong>, <strong>12.5<\/strong>, <strong>14.5<\/strong>, <strong>16.5<\/strong>, y <strong>21 mm<\/strong>, while centre-to-centre spacing <strong>L3<\/strong> steps through <strong>20<\/strong>, <strong>25<\/strong>, <strong>30<\/strong>, <strong>35<\/strong>, <strong>40<\/strong>, y <strong>45 mm<\/strong>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>\u03a6 (mm)<\/th>\n<th>D (mm)<\/th>\n<th>d (mm)<\/th>\n<th>L (mm)<\/th>\n<th>L1 (mm)<\/th>\n<th>L2 (mm)<\/th>\n<th>L3 (mm)<\/th>\n<th>B (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>DT-2-25<\/strong><\/td>\n<td>8.5<\/td>\n<td>11<\/td>\n<td>7.8<\/td>\n<td>86<\/td>\n<td>32<\/td>\n<td>40<\/td>\n<td>20<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-35<\/strong><\/td>\n<td>10.5<\/td>\n<td>12<\/td>\n<td>8.7<\/td>\n<td>98<\/td>\n<td>34<\/td>\n<td>47<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-50<\/strong><\/td>\n<td>10.5<\/td>\n<td>14<\/td>\n<td>9.7<\/td>\n<td>105<\/td>\n<td>40<\/td>\n<td>50<\/td>\n<td>20<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-70<\/strong><\/td>\n<td>12.5<\/td>\n<td>16<\/td>\n<td>12<\/td>\n<td>118<\/td>\n<td>45<\/td>\n<td>55<\/td>\n<td>25<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-95<\/strong><\/td>\n<td>12.5<\/td>\n<td>18<\/td>\n<td>13.5<\/td>\n<td>125<\/td>\n<td>48<\/td>\n<td>57<\/td>\n<td>25<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-120<\/strong><\/td>\n<td>14.5<\/td>\n<td>20<\/td>\n<td>15.5<\/td>\n<td>135<\/td>\n<td>50<\/td>\n<td>65<\/td>\n<td>30<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-150<\/strong><\/td>\n<td>14.5<\/td>\n<td>22<\/td>\n<td>16.5<\/td>\n<td>142<\/td>\n<td>53<\/td>\n<td>68<\/td>\n<td>30<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-185<\/strong><\/td>\n<td>14.5<\/td>\n<td>25<\/td>\n<td>18.5<\/td>\n<td>145<\/td>\n<td>55<\/td>\n<td>71<\/td>\n<td>35<\/td>\n<td>37<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-240<\/strong><\/td>\n<td>16.5<\/td>\n<td>27<\/td>\n<td>21<\/td>\n<td>160<\/td>\n<td>59<\/td>\n<td>74<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-300<\/strong><\/td>\n<td>16.5<\/td>\n<td>30<\/td>\n<td>23<\/td>\n<td>172<\/td>\n<td>62<\/td>\n<td>81<\/td>\n<td>40<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-400<\/strong><\/td>\n<td>16.5<\/td>\n<td>34<\/td>\n<td>26<\/td>\n<td>181<\/td>\n<td>68<\/td>\n<td>82<\/td>\n<td>40<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-500<\/strong><\/td>\n<td>21<\/td>\n<td>38<\/td>\n<td>29.5<\/td>\n<td>203<\/td>\n<td>73<\/td>\n<td>96<\/td>\n<td>45<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td><strong>DT-2-630<\/strong><\/td>\n<td>21<\/td>\n<td>45<\/td>\n<td>35<\/td>\n<td>220<\/td>\n<td>84<\/td>\n<td>107<\/td>\n<td>45<\/td>\n<td>60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Regla de selecci\u00f3n:<\/strong> Use Table A (<strong>DT-2<\/strong>) exclusively for copper conductors (25\u2013630 mm\u00b2), confirming that <strong>\u03a6<\/strong>, <strong>L3<\/strong>, and palm width <strong>B<\/strong> match the equipment terminal drawing.<\/p>\n<h3>Table B: DL-2 Two-Hole Aluminium Cable Lugs (16\u2013630 mm\u00b2, 14 Models)<\/h3>\n<p>de YOCL <a href=\"https:\/\/yocl.com\/es\/product\/dl-2-two-hole-aluminium-cable-lugs\/\">DL-2 two-hole aluminium cable lugs<\/a> are aluminium compression lugs with one conductor barrel and two mounting holes, designed to connect aluminium conductors (16\u2013630 mm\u00b2) to electrical equipment terminals.<\/p>\n<p>The 14-model DL-2 range begins at <strong>DL-2-16<\/strong> (16 mm\u00b2) and is not interchangeable with the copper table: barrel diameters <strong>D<\/strong> y <strong>d<\/strong>, lengths <strong>L \/ L1 \/ L2<\/strong>, y las <strong>240 mm\u00b2<\/strong> y <strong>400 mm\u00b2<\/strong> palm hole patterns differ from DT-2. For joint preparation on aluminium barrels, see <a href=\"https:\/\/yocl.com\/es\/aluminium-cable-lug-antioxidant-compound\/\">compuesto antioxidante para terminales de aluminio<\/a>.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>\u03a6 (mm)<\/th>\n<th>D (mm)<\/th>\n<th>d (mm)<\/th>\n<th>L (mm)<\/th>\n<th>L1 (mm)<\/th>\n<th>L2 (mm)<\/th>\n<th>L3 (mm)<\/th>\n<th>B (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>DL-2-16<\/strong><\/td>\n<td>8.5<\/td>\n<td>10<\/td>\n<td>5.5<\/td>\n<td>93<\/td>\n<td>32<\/td>\n<td>44<\/td>\n<td>20<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-25<\/strong><\/td>\n<td>8.5<\/td>\n<td>12<\/td>\n<td>7<\/td>\n<td>94<\/td>\n<td>33<\/td>\n<td>45<\/td>\n<td>20<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-35<\/strong><\/td>\n<td>10.5<\/td>\n<td>14<\/td>\n<td>8.5<\/td>\n<td>104<\/td>\n<td>42<\/td>\n<td>48<\/td>\n<td>20<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-50<\/strong><\/td>\n<td>10.5<\/td>\n<td>16<\/td>\n<td>9.5<\/td>\n<td>112<\/td>\n<td>47<\/td>\n<td>50<\/td>\n<td>20<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-70<\/strong><\/td>\n<td>12.5<\/td>\n<td>18<\/td>\n<td>12<\/td>\n<td>125<\/td>\n<td>48<\/td>\n<td>59<\/td>\n<td>25<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-95<\/strong><\/td>\n<td>12.5<\/td>\n<td>21<\/td>\n<td>13<\/td>\n<td>136<\/td>\n<td>53<\/td>\n<td>60<\/td>\n<td>25<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-120<\/strong><\/td>\n<td>14.5<\/td>\n<td>23<\/td>\n<td>15<\/td>\n<td>145<\/td>\n<td>55<\/td>\n<td>69<\/td>\n<td>30<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-150<\/strong><\/td>\n<td>14.5<\/td>\n<td>25<\/td>\n<td>16<\/td>\n<td>150<\/td>\n<td>57<\/td>\n<td>70<\/td>\n<td>30<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-185<\/strong><\/td>\n<td>14.5<\/td>\n<td>27<\/td>\n<td>18<\/td>\n<td>162<\/td>\n<td>63<\/td>\n<td>76<\/td>\n<td>35<\/td>\n<td>37<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-240<\/strong><\/td>\n<td>14.5<\/td>\n<td>30<\/td>\n<td>20<\/td>\n<td>170<\/td>\n<td>66<\/td>\n<td>77<\/td>\n<td>35<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-300<\/strong><\/td>\n<td>16.5<\/td>\n<td>34<\/td>\n<td>23<\/td>\n<td>180<\/td>\n<td>73<\/td>\n<td>78<\/td>\n<td>40<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-400<\/strong><\/td>\n<td>21<\/td>\n<td>38<\/td>\n<td>26<\/td>\n<td>195<\/td>\n<td>76<\/td>\n<td>87<\/td>\n<td>40<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-500<\/strong><\/td>\n<td>21<\/td>\n<td>42<\/td>\n<td>30<\/td>\n<td>205<\/td>\n<td>80<\/td>\n<td>91<\/td>\n<td>45<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td><strong>DL-2-630<\/strong><\/td>\n<td>21<\/td>\n<td>45<\/td>\n<td>34.5<\/td>\n<td>210<\/td>\n<td>85<\/td>\n<td>95<\/td>\n<td>45<\/td>\n<td>60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Regla de selecci\u00f3n:<\/strong> Use Table B (<strong>DL-2<\/strong>) exclusively for aluminium conductors (16\u2013630 mm\u00b2), and read <strong>\u03a6<\/strong> y <strong>L3<\/strong> directly from the DL-2 row rather than assuming parity with DT-2.<\/p>\n<h2>Reading the Charts: Selection Order and Worked Examples<\/h2>\n<p>To select the right model without palm-fit errors, follow a strict verification sequence: match conductor size and material to the model first, verify <strong>\u03a6<\/strong> y <strong>L3<\/strong> against the equipment terminal drawing second, and check palm width <strong>B<\/strong> against the terminal face third.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/two-hole-cable-lugs-dt2-vs-dl2.webp\" width=\"1920\" height=\"1080\" alt=\"Catalogue studio comparison of YOCL DT-2 two-hole copper cable lug and DL-2 two-hole aluminium cable lug showing non-interchangeable 240 mm\u00b2 and 400 mm\u00b2 palm specifications.\" \/><figcaption>DT-2 copper and DL-2 aluminium rows are not interchangeable: at 240 mm\u00b2, DT-2-240 uses \u03a6 16.5 mm and L3 40 mm while DL-2-240 uses \u03a6 14.5 mm and L3 35 mm; at 400 mm\u00b2, DT-2-400 uses \u03a6 16.5 mm while DL-2-400 uses \u03a6 21 mm.<\/figcaption><\/figure>\n<h3>Step-by-Step Selection Order<\/h3>\n<ol>\n<li><strong>Conductor size and material \u2192 Model:<\/strong> Pick <strong>DT-2<\/strong> for a copper conductor or <strong>DL-2<\/strong> for an aluminium conductor (never fit an aluminium lug on a copper cable or the reverse; see <a href=\"https:\/\/yocl.com\/es\/copper-vs-aluminium-vs-bimetallic-cable-lugs\/\">terminales de cobre frente a aluminio frente a bimet\u00e1licos<\/a>) and locate the row matching your conductor cross-section in mm\u00b2.<\/li>\n<li><strong>Verify \u03a6 and L3 against the terminal drawing:<\/strong> Check that both the hole diameter <strong>\u03a6<\/strong> como la distancia entre centros de los agujeros <strong>L3<\/strong> in that row match the equipment terminal&#8217;s hole pattern.<\/li>\n<li><strong>Check palm width B against the terminal face:<\/strong> Confirm that <strong>B<\/strong> (de <strong>18 mm<\/strong> up to <strong>60 mm<\/strong>) fits cleanly within the terminal pad width and phase barriers.<\/li>\n<\/ol>\n<h3>Worked Examples: 95 mm\u00b2 Coincidence vs 240 mm\u00b2 and 400 mm\u00b2 Divergence<\/h3>\n<ul>\n<li><strong>95 mm\u00b2 Copper vs Aluminium (Coincidence of One Row):<\/strong><br \/>\n  A <strong>95 mm\u00b2 copper conductor<\/strong> terminating on a two-hole pad with <strong>12.5 mm<\/strong> holes at <strong>25 mm<\/strong> centres selects <strong>DT-2-95<\/strong>, which has <strong>\u03a6 = 12.5 mm<\/strong>, <strong>L3 = 25 mm<\/strong>, y <strong>B = 28 mm<\/strong> (with <strong>D = 18 mm<\/strong>, <strong>d = 13.5 mm<\/strong>, <strong>L = 125 mm<\/strong>, <strong>L1 = 48 mm<\/strong>, <strong>L2 = 57 mm<\/strong>). For a <strong>95 mm\u00b2 aluminium conductor<\/strong>, <strong>DL-2-95<\/strong> happens to share <strong>\u03a6 = 12.5 mm<\/strong>, <strong>L3 = 25 mm<\/strong>, y <strong>B = 28 mm<\/strong> (while its barrel and length dimensions change to <strong>D = 21 mm<\/strong>, <strong>d = 13 mm<\/strong>, <strong>L = 136 mm<\/strong>, <strong>L1 = 53 mm<\/strong>, <strong>L2 = 60 mm<\/strong>). That palm match at 95 mm\u00b2 is a coincidence of this row, not a cross-table rule.<\/li>\n<li><strong>240 mm\u00b2 Copper vs Aluminium (Both \u03a6 and L3 Diverge):<\/strong><br \/>\n  A <strong>240 mm\u00b2<\/strong>, the two materials diverge in both palm fit dimensions. In Table A, <strong>DT-2-240<\/strong> (copper) has <strong>\u03a6 = 16.5 mm<\/strong>, <strong>D = 27 mm<\/strong>, <strong>d = 21 mm<\/strong>, <strong>L = 160 mm<\/strong>, <strong>L1 = 59 mm<\/strong>, <strong>L2 = 74 mm<\/strong>, <strong>L3 = 40 mm<\/strong>, y <strong>B = 40 mm<\/strong>. In Table B, <strong>DL-2-240<\/strong> (aluminium) has <strong>\u03a6 = 14.5 mm<\/strong>, <strong>D = 30 mm<\/strong>, <strong>d = 20 mm<\/strong>, <strong>L = 170 mm<\/strong>, <strong>L1 = 66 mm<\/strong>, <strong>L2 = 77 mm<\/strong>, <strong>L3 = 35 mm<\/strong>, y <strong>B = 40 mm<\/strong>. A buyer terminating a 240 mm\u00b2 aluminium cable must check the <strong>DL-2-240<\/strong> row separately: its <strong>14.5 mm<\/strong> holes at <strong>35 mm<\/strong> centres will not fit a terminal drilled for <strong>16.5 mm<\/strong> holes at <strong>40 mm<\/strong> centres.<\/li>\n<li><strong>400 mm\u00b2 Copper vs Aluminium (Hole Diameter \u03a6 Diverges):<\/strong><br \/>\n  A <strong>400 mm\u00b2<\/strong>, both rows share <strong>L3 = 40 mm<\/strong> y <strong>B = 50 mm<\/strong>, but <strong>DT-2-400<\/strong> tiene <strong>\u03a6 = 16.5 mm<\/strong> (<strong>D = 34<\/strong>, <strong>d = 26<\/strong>, <strong>L = 181<\/strong>, <strong>L1 = 68<\/strong>, <strong>L2 = 82 mm<\/strong>) whereas <strong>DL-2-400<\/strong> tiene <strong>\u03a6 = 21 mm<\/strong> (<strong>D = 38<\/strong>, <strong>d = 26<\/strong>, <strong>L = 195<\/strong>, <strong>L1 = 76<\/strong>, <strong>L2 = 87 mm<\/strong>).<\/li>\n<\/ul>\n<h2>When One Bolt Is Not Enough: How the Terminal and Application Decide<\/h2>\n<p>Answering when one bolt is not enough begins with the equipment terminal itself: the terminal as built decides first. A single-hole equipment terminal takes a single-hole lug, and no lug preference overrides the hardware pattern on the equipment.<\/p>\n<p>Where termination geometry is being specified or matched on site, three rules apply:<\/p>\n<ul>\n<li><strong>The equipment terminal pattern comes first:<\/strong> Two-hole palms belong on equipment terminals and busbar ends that provide a matching two-hole pattern (<strong>\u03a6<\/strong> y <strong>L3<\/strong>). Where an equipment stud or busbar pad has only one hole, specify a single-hole lug.<\/li>\n<li><strong>Where orientation lock matters:<\/strong> Two-hole palms are specified where heavy feeders could twist a single-bolt palm out of alignment during installation pulling, where tight phase-to-phase spacing requires the palm to stay fixed inline with the busbar, or where the equipment manufacturer provides two inline studs to prevent palm rotation.<\/li>\n<li><strong>Conductor size is a hint, not a current rule:<\/strong> YOCL&#8217;s two-hole ranges start at <strong>25 mm\u00b2<\/strong> in copper (<strong>DT-2<\/strong>) y <strong>16 mm\u00b2<\/strong> in aluminium (<strong>DL-2<\/strong>) and run to <strong>630 mm\u00b2<\/strong>, while smaller wire sizes are covered by single-hole ranges (see <a href=\"https:\/\/yocl.com\/es\/cable-lug-size-chart\/\">la tabla de tama\u00f1os de terminales de cable<\/a>). Do not apply an assumed current threshold for switching to two holes\u2014the product pages publish no current ratings for these series.<\/li>\n<\/ul>\n<h2>Installation Notes: Both Bolts Installed and Pre-Crimp Spacing Checks<\/h2>\n<p>Installing a two-hole lug requires two field habits that follow directly from the data: every two-hole palm must be fastened with both bolts, and <strong>L3<\/strong> must be verified against the terminal before the barrel is crimped onto the cable.<\/p>\n<ul>\n<li><strong>Both bolts belong to the joint:<\/strong> Fitting only one bolt of a two-hole palm into a single-hole terminal leaves the palm free to rotate around that single bolt\u2014the exact failure mode the second hole exists to prevent\u2014while leaving half of the palm overhanging the contact pad.<\/li>\n<li><strong>Check L3 before crimping:<\/strong> Verify <strong>\u03a6<\/strong> y <strong>L3<\/strong> on the terminal drawing or by measuring centre-to-centre directly on the terminal pad before crimping. After compression, a lug with the wrong hole spacing cannot be exchanged without cutting the conductor back.<\/li>\n<li><strong>Use the matching crimp die:<\/strong> Match the compression die to the barrel&#8217;s series and size (<strong>D<\/strong> y <strong>d<\/strong> differ between DT-2 and DL-2); see <a href=\"https:\/\/yocl.com\/es\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">c\u00f3mo combinar terminales de cable, matrices de crimpado y conductores<\/a>.<\/li>\n<\/ul>\n<h2>Preguntas frecuentes<\/h2>\n<h3>Can I use a two-hole cable lug on a terminal with only one hole?<\/h3>\n<p>No. Both holes of a two-hole palm belong to the joint. Fastening only one bolt of a two-hole lug onto a single-hole terminal leaves the palm free to rotate on that single bolt\u2014the exact problem the second hole exists to prevent. Always fit a single-hole lug to a single-hole terminal.<\/p>\n<h3>How do I measure hole spacing on a two-hole lug?<\/h3>\n<p>Hole spacing <strong>L3<\/strong> is measured centre-to-centre between the two mounting holes in millimetres, not edge-to-edge. Measure the centre-to-centre distance and hole diameter <strong>\u03a6<\/strong> on the equipment terminal or drawing, then match both numbers to the <strong>\u03a6<\/strong> y <strong>L3<\/strong> columns in the DT-2 or DL-2 table.<\/p>\n<h3>Is a two-hole cable lug stronger than a single-hole lug?<\/h3>\n<p>YOCL&#8217;s DT-2 and DL-2 product pages publish no comparative mechanical strength, torque, vibration, or current figures. The difference is fixing geometry and terminal fit: two inline bolts separated by <strong>L3<\/strong> lock the palm&#8217;s orientation so it cannot rotate around a single bolt axis.<\/p>\n<h3>Does the hole spacing change with lug size?<\/h3>\n<p>Yes. Across both the DT-2 (25\u2013630 mm\u00b2) and DL-2 (16\u2013630 mm\u00b2) charts, centre-to-centre hole spacing <strong>L3<\/strong> steps from <strong>20 mm<\/strong> a <strong>25 mm<\/strong>, <strong>30 mm<\/strong>, <strong>35 mm<\/strong>, <strong>40 mm<\/strong>, y <strong>45 mm<\/strong> as conductor size increases, and differs between copper and aluminium at <strong>240 mm\u00b2<\/strong> (<strong>40 mm<\/strong> vs <strong>35 mm<\/strong>).<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><strong>Informaci\u00f3n del producto ELECTRIC YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/dt-2-two-hole-copper-cable-lugs\/\">DT-2 Terminales de cable de cobre de dos orificios<\/a>: copper two-hole lug specifications, drawing field definitions (\u03a6, D, d, L, L1, L2, L3, B), and 13-model table (25\u2013630 mm\u00b2).<\/li>\n<li><strong>Informaci\u00f3n del producto ELECTRIC YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/dl-2-two-hole-aluminium-cable-lugs\/\">Terminales de Aluminio de DL-2 Dos Orificios<\/a>: aluminium two-hole lug specifications, drawing field definitions (\u03a6, D, d, L, L1, L2, L3, B), and 14-model table (16\u2013630 mm\u00b2).<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Two-hole cable lugs are compression tube terminals built with one conductor barrel and an extended flat mounting palm punched with two inline bolt holes, locking the palm&#8217;s angular orientation on two-stud equipment terminals and busbars. Across YOCL ELECTRIC&#8217;s DT-2 copper and DL-2 aluminium series, 27 models cover 16\u2013630 mm\u00b2. Specifying a two-hole palm requires more [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3496,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-3497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/comments?post=3497"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3497\/revisions"}],"predecessor-version":[{"id":3498,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3497\/revisions\/3498"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/3496"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=3497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/categories?post=3497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/tags?post=3497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}