{"id":3509,"date":"2026-11-18T07:11:25","date_gmt":"2026-11-18T07:11:25","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=1c507a41b93f835c8d127c1309a252cd75bf9e083efdbb24e728a8e17ea57d14"},"modified":"2026-11-18T07:11:25","modified_gmt":"2026-11-18T07:11:25","slug":"bell-mouth-cable-lugs","status":"publish","type":"post","link":"https:\/\/yocl.com\/es\/bell-mouth-cable-lugs\/","title":{"rendered":"Terminales de cable con entrada abocardada: por qu\u00e9 es importante la entrada del barril ensanchada para conductores trenzados"},"content":{"rendered":"<p><strong>Terminales de cable con entrada abocardada<\/strong> son terminales tubulares de compresi\u00f3n de cobre formados con una abertura ensanchada en forma de embudo en la parte posterior del barril del conductor para recoger y guiar los hilos de cobre trenzados limpiamente hacia el interior. En la serie SC(JGB de YOCL ELECTRIC, los modelos 16 cubren conductores de 6 a 630 mm\u00b2.<\/p>\n<p>La mayor\u00eda de las especificaciones de los terminales de cable se centran en el orificio del perno de la pala y en el calibre del barril, tratando la boca posterior del barril como un corte cuadrado simple. Sin embargo, en cables trenzados de m\u00faltiples hilos, ese borde de entrada determina si cada hilo de cobre entra en la zona de crimpado o si se engancha en el borde durante el montaje. Para mantener distintos los temas relacionados, el procedimiento de crimpado (longitud de pelado, profundidad de inserci\u00f3n, colocaci\u00f3n del crimpado y comprobaciones posteriores al crimpado) pertenece a <a href=\"https:\/\/yocl.com\/es\/how-to-crimp-cable-lugs\/\">c\u00f3mo crimpar terminales de cable<\/a>, la selecci\u00f3n de herramientas pertenece a <a href=\"https:\/\/yocl.com\/es\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">c\u00f3mo combinar terminales de cable, matrices de crimpado y conductores<\/a>, y el dimensionamiento general del calibre respecto al conductor pertenece a <a href=\"https:\/\/yocl.com\/es\/cable-lug-size-chart\/\">la tabla de tama\u00f1os de terminales de cable<\/a>. Las familias de terminales con mirilla o ventana de inspecci\u00f3n (como las series YOCL SC(JGK) y JM\/JGY) abordan la verificaci\u00f3n visual de la profundidad en lugar de la geometr\u00eda de entrada del conductor y son una caracter\u00edstica distinta del cuerpo del terminal.<\/p>\n<h2>El problema de inserci\u00f3n de conductores trenzados en una boca de terminal recta<\/h2>\n<p>Un conductor de cobre trenzado se comporta como un haz el\u00e1stico de hilos individuales en lugar de una varilla r\u00edgida. Al empujarlo contra una boca de terminal de 90 grados de corte recto, los hilos exteriores se enganchan f\u00e1cilmente en el borde del terminal, se abren hacia afuera o se doblan a lo largo de la pared exterior en lugar de entrar en el orificio.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-entry-comparison.webp\" width=\"1920\" height=\"1080\" alt=\"Conceptual outline diagram comparing a stranded copper conductor catching and splaying on a straight-cut barrel mouth versus entering smoothly through a flared bell mouth into bore d.\" \/><figcaption>En una boca de terminal de corte recto, los hilos exteriores de un haz trenzado el\u00e1stico pueden engancharse en el borde cuadrado y abrirse hacia afuera; una boca acampanada act\u00faa como un embudo que gu\u00eda el haz completo hacia el interior del orificio d.<\/figcaption><\/figure>\n<p>En el taller o dentro de un armario de aparamenta, el enganche de los hilos en una entrada de terminal recta crea dos defectos mec\u00e1nicos inmediatos antes incluso de que la herramienta de crimpado toque el terminal:<\/p>\n<ul>\n<li><strong>Hilos atrapados fuera del terminal:<\/strong> Una vez que se retira el aislamiento de un cable trenzado, la capa exterior de hilos se relaja ligeramente hacia afuera. Si el di\u00e1metro interior del terminal <strong>d<\/strong> se ajusta estrechamente al haz del conductor, incluso una entrada ligeramente descentrada contra un borde de corte cuadrado engancha uno o m\u00e1s hilos exteriores. Esos hilos escapados se doblan hacia atr\u00e1s fuera de la pared del terminal, lo que reduce la secci\u00f3n transversal del conductor capturada dentro de la uni\u00f3n y deja hilos de cobre expuestos que pueden desviarse hacia terminales de fase adyacentes o partes met\u00e1licas conectadas a tierra.<\/li>\n<li><strong>Profundidad de inserci\u00f3n incompleta:<\/strong> Incluso cuando un hilo atrapado no se desprende completamente por el exterior del tubo, el amontonamiento en el borde del cuerpo del terminal bloquea el haz e impide que el conductor alcance la profundidad de asiento completa dentro del cuerpo.<\/li>\n<li><strong>Por qu\u00e9 las secciones transversales m\u00e1s grandes ofrecen mayor resistencia:<\/strong> A <strong>6 mm\u00b2<\/strong>, un cable de cobre de pocos hilos es f\u00e1cil de retorcer entre dos dedos e introducir en un tubo recto. A partir de <strong>95 mm\u00b2<\/strong> y superiores, pasando por <strong>185 mm\u00b2<\/strong>, <strong>300 mm\u00b2<\/strong>, y <strong>630 mm\u00b2<\/strong>\u2014la rigidez de los cables gruesos, los radios de curvatura estrechos en las envolventes y un mayor n\u00famero de hilos hacen que sea mucho m\u00e1s dif\u00edcil mantener una alineaci\u00f3n perfectamente coaxial manualmente, por lo que los bordes cuadrados del terminal atrapan los hilos con mucha m\u00e1s facilidad durante el montaje.<\/li>\n<\/ul>\n<h2>Qu\u00e9 cambia la entrada abocardada del terminal y qu\u00e9 no<\/h2>\n<p>Una boca de campana es un embudo c\u00f3nico suave formado en el extremo de entrada del terminal de cobre: como indica la especificaci\u00f3n del producto YOCL SC(JGB), la abertura abocardada ayuda a guiar los conductores, incluidos los conductores de cobre trenzado, hacia el terminal. M\u00e1s all\u00e1 de ese borde de entrada, la estructura de la uni\u00f3n mec\u00e1nica y el\u00e9ctrica del terminal permanece inalterada.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-jgb-vs-jga.webp\" width=\"1920\" height=\"1080\" alt=\"Catalogue studio comparison of YOCL SC(JGB) bell mouth flared-entry copper cable lug and SC(JGA) standard straight-entry copper cable lug.\" \/><figcaption>Comparaci\u00f3n de los terminales de cobre con boca de campana YOCL SC(JGB) con los terminales de cobre de entrada est\u00e1ndar SC(JGA): el embudo abocardado solo cambia la entrada del conductor, mientras que el di\u00e1metro interior del cuerpo, la zona de crimpado y la pala de un solo orificio mantienen su funci\u00f3n.<\/figcaption><\/figure>\n<p>Separar lo que cambia el abocardado de lo que permanece id\u00e9ntico evita una interpretaci\u00f3n excesiva de la geometr\u00eda del cat\u00e1logo:<\/p>\n<ul>\n<li><strong>Lo que cambia el abocardado (entrada de montaje):<\/strong> En lugar de presentar un resalte anular plano al extremo del cable pelado, la boca abocardada ensancha la abertura objetivo y se estrecha suavemente hacia el interior del orificio cil\u00edndrico. Los hilos exteriores ligeramente relajados entran en contacto con una rampa inclinada que vuelve a agrupar el cable y gu\u00eda el haz de forma coaxial hacia el interior del tubo.<\/li>\n<li><strong>Lo que permanece id\u00e9ntico a continuaci\u00f3n:<\/strong> M\u00e1s all\u00e1 del ensanchamiento de entrada corto, el calibre cil\u00edndrico del cuerpo (<strong>d<\/strong> en la tabla a continuaci\u00f3n), el di\u00e1metro exterior del cuerpo (<strong>D<\/strong>), la zona de compresi\u00f3n por crimpado, la selecci\u00f3n de la matriz y la pala de montaje plana de un solo orificio funcionan exactamente de la misma manera que en los terminales de entrada recta est\u00e1ndar de YOCL <a href=\"https:\/\/yocl.com\/es\/product\/sc-jga-copper-cable-lugs\/\">SC(JGA) terminales de cobre<\/a>.<\/li>\n<li><strong>Una caracter\u00edstica de inserci\u00f3n, nunca una mejora el\u00e9ctrica:<\/strong> YOCL no publica ninguna clasificaci\u00f3n de corriente, valor de tracci\u00f3n o clasificaci\u00f3n de temperatura para la serie SC(JGB, y la boca ensanchada nunca debe considerarse como un factor que proporcione mayor ampacidad, menor resistencia de contacto o temperaturas de funcionamiento m\u00e1s bajas. La calidad de la uni\u00f3n el\u00e9ctrica proviene de un ajuste adecuado entre el conductor y el calibre y de la compresi\u00f3n en fr\u00edo del cuerpo; la boca acampanada simplemente ayuda a garantizar que todos los hilos entren realmente en ese cuerpo antes del crimpado.<\/li>\n<\/ul>\n<h2>Tabla de tama\u00f1os de terminales de cable con boca acampanada: YOCL Serie SC(JGB (6\u2013630 mm\u00b2)<\/h2>\n<p>Especificaci\u00f3n <strong>terminales de cable con boca acampanada<\/strong> en YOCL de ELECTRIC <a href=\"https:\/\/yocl.com\/es\/product\/sc-jgb-bell-mouth-copper-cable-lugs\/\">SC(JGB) terminales de cable de cobre con boca de campana<\/a> range covers 16 copper models from <strong>SC(JGB)-6<\/strong> a <strong>SC(JGB)-630<\/strong>, where each model suffix identifies nominal copper conductor cross-section in mm\u00b2 and every dimensional column is given in millimetres.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-dimension-guide.webp\" width=\"1920\" height=\"1080\" alt=\"Orthographic dimension drawing for YOCL SC(JGB) bell mouth copper cable lugs showing overall length L, barrel inner diameter d, barrel outer diameter D, palm width B, and fixed mounting-hole \u03a6 range options.\" \/><figcaption>YOCL SC(JGB) dimension definitions: d is barrel inner bore, D is barrel outer diameter, L is overall length, B is palm width, and the \u03a6 range lists fixed hole diameters available per model at order time.<\/figcaption><\/figure>\n<h3>Understanding the Mounting-Hole \u03a6-Range Rule Before Ordering<\/h3>\n<p>Look carefully at the <strong>Mounting-Hole \u03a6 Range (mm)<\/strong> column in the SC(JGB) table below. Each row prints a millimetre range\u2014such as <strong>6.4\u20138.4 mm<\/strong> on <strong>SC(JGB)-6<\/strong> o <strong>10.5\u201318.5 mm<\/strong> on <strong>SC(JGB)-240<\/strong>\u2014because each conductor model is manufactured in multiple fixed stud-hole diameters within that span.<\/p>\n<p>As stated on YOCL&#8217;s SC(JGB) product page, <strong>that range represents the available hole sizes for the model, not an adjustable, slotted, or one-size-fits-all hole<\/strong>. Every supplied lug has a single round mounting hole punched to one specific diameter. When requesting a quotation or placing an order, specify three items together:<\/p>\n<ol>\n<li><strong>Complete model code<\/strong> (for example, <strong>SC(JGB)-95<\/strong> o <strong>SC(JGB)-240<\/strong>);<\/li>\n<li><strong>Required mounting-hole diameter<\/strong> (chosen from that model&#8217;s published <strong>\u03a6<\/strong> range to match your equipment bolt or stud);<\/li>\n<li><strong>Order quantity<\/strong>.<\/li>\n<\/ol>\n<h3>Complete YOCL SC(JGB) Dimensional Specification Table (16 Models)<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Mounting-Hole \u03a6 Range \u2014 Available Hole Sizes (mm)<\/th>\n<th>D Barrel Outer (mm)<\/th>\n<th>d Barrel Inner (mm)<\/th>\n<th>L Overall (mm)<\/th>\n<th>B Palm Width (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>SC(JGB)-6<\/strong><\/td>\n<td>6.4\u20138.4<\/td>\n<td>5.5<\/td>\n<td>4.5<\/td>\n<td>23<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-10<\/strong><\/td>\n<td>6.4\u20138.4<\/td>\n<td>6.5<\/td>\n<td>5.5<\/td>\n<td>27<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-16<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>8<\/td>\n<td>6.6<\/td>\n<td>33<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-25<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>9<\/td>\n<td>7.2<\/td>\n<td>36<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-35<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>10.5<\/td>\n<td>8.7<\/td>\n<td>42<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-50<\/strong><\/td>\n<td>8.4\u201312.5<\/td>\n<td>12<\/td>\n<td>10<\/td>\n<td>49<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-70<\/strong><\/td>\n<td>8.4\u201312.5<\/td>\n<td>14.5<\/td>\n<td>12.1<\/td>\n<td>55<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-95<\/strong><\/td>\n<td>8.4\u201316.5<\/td>\n<td>16<\/td>\n<td>13.2<\/td>\n<td>59<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-120<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>19<\/td>\n<td>15.6<\/td>\n<td>67<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-150<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>20.5<\/td>\n<td>16.9<\/td>\n<td>72<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-185<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>23.5<\/td>\n<td>19.5<\/td>\n<td>78<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-240<\/strong><\/td>\n<td>10.5\u201318.5<\/td>\n<td>26<\/td>\n<td>21.4<\/td>\n<td>90<\/td>\n<td>38<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-300<\/strong><\/td>\n<td>10.5\u201318.5<\/td>\n<td>30<\/td>\n<td>24.4<\/td>\n<td>100<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-400<\/strong><\/td>\n<td>10.5\u201320.5<\/td>\n<td>34<\/td>\n<td>28.2<\/td>\n<td>113<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-500<\/strong><\/td>\n<td>12.5\u201322.5<\/td>\n<td>38<\/td>\n<td>32<\/td>\n<td>126<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-630<\/strong><\/td>\n<td>12.5\u201322.5<\/td>\n<td>45<\/td>\n<td>37.8<\/td>\n<td>145<\/td>\n<td>65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Regla de selecci\u00f3n:<\/strong> Match nominal copper conductor cross-section to the <strong>SC(JGB<\/strong> model suffix first, verify stripped conductor clearance against barrel inner diameter <strong>d<\/strong> (de <strong>4.5 mm<\/strong> at 6 mm\u00b2 up to <strong>37.8 mm<\/strong> at 630 mm\u00b2), specify the exact fixed mounting-hole diameter from the row&#8217;s <strong>\u03a6<\/strong> range for your terminal bolt, and check overall length <strong>L<\/strong> (23\u2013145 mm) and palm width <strong>B<\/strong> (10\u201365 mm) against terminal compartment barriers. For the general bore-and-stud sizing method across lug families, see <a href=\"https:\/\/yocl.com\/es\/cable-lug-size-chart\/\">la tabla de tama\u00f1os de terminales de cable<\/a>.<\/p>\n<p>For example, terminating a <strong>95 mm\u00b2<\/strong> stranded copper feeder selects <strong>SC(JGB)-95<\/strong> (<strong>d = 13.2 mm<\/strong>, <strong>D = 16 mm<\/strong>, <strong>L = 59 mm<\/strong>, <strong>B = 24 mm<\/strong>), and the buyer specifies the exact required bolt-hole diameter within <strong>8.4\u201316.5 mm<\/strong> at order time; stepping up to a <strong>240 mm\u00b2<\/strong> feeder selects <strong>SC(JGB)-240<\/strong> (<strong>d = 21.4 mm<\/strong>, <strong>D = 26 mm<\/strong>, <strong>L = 90 mm<\/strong>, <strong>B = 38 mm<\/strong>) with its fixed hole chosen within <strong>10.5\u201318.5 mm<\/strong>.<\/p>\n<h2>When Bell Mouth Lugs Earn Their Place \u2014 and When Straight Entry Is Fine<\/h2>\n<p>Flared-entry lugs are the practical answer to a specific wire-insertion problem rather than an automatic replacement for every straight-entry lug on a bill of materials. Matching the barrel mouth to conductor construction and assembly workflow keeps selection grounded:<\/p>\n<ul>\n<li><strong>Where bell mouth lugs earn their place:<\/strong><\/li>\n<li><strong>Stranded and flexible multi-wire copper conductors:<\/strong> The higher the wire count and the finer the individual copper strands, the more readily the stripped end mushrooms or catches on a square tube edge.<\/li>\n<li><strong>Larger cable cross-sections:<\/strong> On heavy feeders\u2014such as <strong>95 mm\u00b2<\/strong> (<strong>d = 13.2 mm<\/strong>), <strong>185 mm\u00b2<\/strong> (<strong>d = 19.5 mm<\/strong>), <strong>300 mm\u00b2<\/strong> (<strong>d = 24.4 mm<\/strong>), and <strong>630 mm\u00b2<\/strong> (<strong>d = 37.8 mm<\/strong>)\u2014guiding a stiff cable end onto a lug inside a tight termination box benefits directly from a funnelled entry.<\/li>\n<li><strong>Repetitive panel and harness production:<\/strong> When an assembly line terminates hundreds of cable ends per shift, every snagged strand forces the operator to pull the cable out, re-lay the wires, and repeat the insertion. A flared entry cuts down that repetitive assembly rework.<\/li>\n<li><strong>When a standard straight entry is completely adequate:<\/strong><\/li>\n<li><strong>Solid copper conductors:<\/strong> A single solid wire has no individual strands to splay or fold back at the mouth.<\/li>\n<li><strong>Small stranded conductors that seat cleanly:<\/strong> On compact sizes such as <strong>6 mm\u00b2<\/strong> o <strong>10 mm\u00b2<\/strong> where a neatly stripped conductor slips straight into bore <strong>d<\/strong> without catching, a standard straight-entry lug performs the termination without difficulty.<\/li>\n<li><strong>Undisturbed bench terminations verified by trial fit:<\/strong> If the stripped conductor will not be bent or handled roughly between stripping and crimping, and a dry trial fit confirms the wire bundle enters the barrel cleanly to full depth, barrel entry geometry is not your bottleneck.<\/li>\n<\/ul>\n<h2>Insertion Practice with a Flared Barrel Entry<\/h2>\n<p>A flared mouth guides strands inward, but it does not excuse careless wire preparation or blind crimping. Follow three assembly habits whenever terminating stranded copper conductors into an SC(JGB) lug:<\/p>\n<ol>\n<li><strong>Re-twist the strand lay by hand after stripping:<\/strong> Pulling off tough cable insulation often untwists or ruffles the outer copper layer. Before presenting the wire to the lug, gently twist the stripped strands in the natural direction of their lay so the bundle enters the bell mouth as a single coherent cylinder.<\/li>\n<li><strong>Seat the conductor fully home before compressing:<\/strong> Push the cable smoothly through the flare until the conductor reaches full insertion depth inside the barrel; for strip-length matching, seating depth criteria, and crimp placement along the barrel, follow <a href=\"https:\/\/yocl.com\/es\/how-to-crimp-cable-lugs\/\">c\u00f3mo crimpar terminales de cable<\/a>.<\/li>\n<li><strong>Inspect the bell mouth rim before closing the crimping tool:<\/strong> Pause and look all the way around the flared entry lip before applying pressure. <strong>Zero strands may sit outside the flare.<\/strong> Any wire resting outside the bell mouth is outside the crimp barrel\u2014closing the die over it locks a reduced-section joint and a loose external copper whisker permanently in place. If even one strand escapes, withdraw the cable, re-form the lay, and insert again before crimping.<\/li>\n<\/ol>\n<h2>Preguntas frecuentes<\/h2>\n<h3>Does a bell mouth cable lug carry more current than a standard lug?<\/h3>\n<p>No. YOCL publishes no current rating, tensile figure, or temperature rating for the SC(JGB) series, and the flared mouth provides no ampacity, resistance, or thermal advantage over a straight-entry lug. Electrical joint quality is determined by proper bore fit (<strong>d<\/strong>) and barrel compression, which match standard copper tube lugs in form.<\/p>\n<h3>Is the mounting hole on an SC(JGB) lug adjustable?<\/h3>\n<p>No. The <strong>Mounting-Hole \u03a6 Range<\/strong> in the SC(JGB) chart (<strong>6.4\u20138.4 mm<\/strong> through <strong>12.5\u201322.5 mm<\/strong>) lists the range of fixed circular hole diameters manufactured for each model\u2014never a slotted or adjustable hole. Specify the model code, the exact required mounting-hole diameter, and quantity when ordering.<\/p>\n<h3>Do I need different crimp dies for bell mouth cable lugs?<\/h3>\n<p>The crimp is made on the cylindrical barrel body downstream of the flared mouth, just as on straight-entry copper cable lugs (<strong>D<\/strong> desde <strong>5.5 mm<\/strong> a <strong>45 mm<\/strong> y <strong>d<\/strong> desde <strong>4.5 mm<\/strong> a <strong>37.8 mm<\/strong> across 6\u2013630 mm\u00b2). Do not assume a special bell-mouth die; follow <a href=\"https:\/\/yocl.com\/es\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">c\u00f3mo combinar terminales de cable, matrices de crimpado y conductores<\/a>.<\/p>\n<h3>Should I choose a bell mouth lug or a peephole lug?<\/h3>\n<p>They solve two different assembly tasks. A bell mouth lug (<strong>SC(JGB<\/strong>) flares the rear barrel entry to guide multi-wire stranded conductors smoothly into the bore without splaying strands, whereas a peephole lug (such as YOCL&#8217;s <strong>SC(JGK<\/strong> o <strong>JM\/JGY<\/strong> series) provides an inspection hole to check conductor seating depth before crimping.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><strong>Informaci\u00f3n del producto ELECTRIC YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/sc-jgb-bell-mouth-copper-cable-lugs\/\">SC(JGB) Terminales de cobre con boca de campana<\/a>: flared-entry copper lug specifications, mounting-hole \u03a6-range ordering rules, and 16-model dimensional table (6\u2013630 mm\u00b2).<\/li>\n<li><strong>Informaci\u00f3n del producto ELECTRIC YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/es\/product\/sc-jga-copper-cable-lugs\/\">SC(JGA) Terminales de cobre<\/a>: standard straight-entry copper tube cable lug counterpart series (6\u2013630 mm\u00b2).<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Bell mouth cable lugs are copper compression tube terminals formed with a funnel-shaped, flared opening at the rear of the conductor barrel to gather and guide multi-wire copper strands cleanly into the bore. Across YOCL ELECTRIC&#8217;s SC(JGB) series, 16 models cover 6\u2013630 mm\u00b2 conductors. Most cable-lug specifications focus on the palm bolt hole and barrel [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3508,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-3509","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/comments?post=3509"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3509\/revisions"}],"predecessor-version":[{"id":3510,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/posts\/3509\/revisions\/3510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/3508"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=3509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/categories?post=3509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/tags?post=3509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}