{"id":1016,"date":"2026-09-30T04:17:51","date_gmt":"2026-09-30T04:17:51","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1016"},"modified":"2026-10-04T14:42:34","modified_gmt":"2026-10-04T14:42:34","slug":"nickel-plated-brass-waterproof-breathable-vent-plugs","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/nickel-plated-brass-waterproof-breathable-vent-plugs\/","title":{"rendered":"Nickel-Plated Brass Waterproof Breathable Vent Plugs"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>Nickel-Plated Brass Waterproof Breathable Vent Plugs provide a vented fitting for threaded enclosure openings. Air permeability varies by specification and is listed as a minimum value at 70 mbar. The supplied catalog identifies brass construction with nickel plating and an IP68 protection level.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li>Metric, G and NPT thread specifications with individual airflow and dimension values.<\/li>\n<li>Minimum airflow and mechanical dimensions are listed together for each configuration.<\/li>\n<li>Nickel-plated brass finish throughout the listed range.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Catalog specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Material<\/td>\n<td>Lat\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Surface finish<\/td>\n<td>Nickel plated<\/td>\n<\/tr>\n<tr>\n<td>Air permeability test pressure<\/td>\n<td>70 mbar<\/td>\n<\/tr>\n<tr>\n<td>Catalog-listed protection level<\/td>\n<td>IP68; test depth and duration not supplied<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Models and Dimensions<\/h2>\n<p>All dimensions are in mm. Air permeability is in mL\/min at 70 mbar. H is total length, GL is thread length, and AG is the wrench dimension.<\/p>\n<h3>Metric Specifications<\/h3>\n<p>The trailing value in each printed metric designation matches the GL dimension.<\/p>\n<table>\n<thead>\n<tr>\n<th>Catalog specification<\/th>\n<th>Minimum air permeability<\/th>\n<th>H<\/th>\n<th>Thread \u00d8<\/th>\n<th>GL<\/th>\n<th>AG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M5\u00d70.8-5<\/td>\n<td>\u2265200<\/td>\n<td>13<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M5\u00d70.8-7<\/td>\n<td>\u2265300<\/td>\n<td>15<\/td>\n<td>5<\/td>\n<td>7<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>M6\u00d71-7<\/td>\n<td>\u2265300<\/td>\n<td>15<\/td>\n<td>6<\/td>\n<td>7<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>M8\u00d71.25-7<\/td>\n<td>\u2265800<\/td>\n<td>15.5<\/td>\n<td>8<\/td>\n<td>7<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>M8\u00d71-7<\/td>\n<td>\u2265800<\/td>\n<td>15.5<\/td>\n<td>8<\/td>\n<td>7<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>M10\u00d71.5-8<\/td>\n<td>\u22651200<\/td>\n<td>17<\/td>\n<td>10<\/td>\n<td>8<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>M10\u00d70.75-8<\/td>\n<td>\u22651200<\/td>\n<td>17<\/td>\n<td>10<\/td>\n<td>8<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>M12\u00d71-8.5<\/td>\n<td>\u22651500<\/td>\n<td>17.5<\/td>\n<td>12<\/td>\n<td>8.5<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>M12\u00d71.5-8.5<\/td>\n<td>\u22651500<\/td>\n<td>17.5<\/td>\n<td>12<\/td>\n<td>8.5<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>M14\u00d71.5-10<\/td>\n<td>\u22651500<\/td>\n<td>19<\/td>\n<td>14<\/td>\n<td>10<\/td>\n<td>19<\/td>\n<\/tr>\n<tr>\n<td>M16\u00d71.5-10<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>16<\/td>\n<td>10<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>M18\u00d71.5-10<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>18<\/td>\n<td>10<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>M20\u00d71.5-10<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>20<\/td>\n<td>10<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>M22\u00d71.5-10<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>22<\/td>\n<td>10<\/td>\n<td>27<\/td>\n<\/tr>\n<tr>\n<td>M24\u00d71.5-8<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>24<\/td>\n<td>8<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>M25\u00d71.5-10<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>25<\/td>\n<td>10<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>M27\u00d71.5-10<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>27<\/td>\n<td>10<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>M32\u00d71.5-15<\/td>\n<td>\u22655500<\/td>\n<td>27<\/td>\n<td>32<\/td>\n<td>15<\/td>\n<td>37<\/td>\n<\/tr>\n<tr>\n<td>M40\u00d71.5-15<\/td>\n<td>\u22658500<\/td>\n<td>29<\/td>\n<td>40<\/td>\n<td>15<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td>M50\u00d71.5-15<\/td>\n<td>\u226515000<\/td>\n<td>30<\/td>\n<td>50<\/td>\n<td>15<\/td>\n<td>55<\/td>\n<\/tr>\n<tr>\n<td>M63\u00d71.5-15<\/td>\n<td>\u226518000<\/td>\n<td>30<\/td>\n<td>63<\/td>\n<td>15<\/td>\n<td>68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>G and NPT Specifications<\/h3>\n<table>\n<thead>\n<tr>\n<th>Catalog specification<\/th>\n<th>Minimum air permeability<\/th>\n<th>H<\/th>\n<th>Thread \u00d8<\/th>\n<th>GL<\/th>\n<th>AG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>G1\/8<\/td>\n<td>\u22651200<\/td>\n<td>17<\/td>\n<td>9.8<\/td>\n<td>8<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>G1\/4<\/td>\n<td>\u22651500<\/td>\n<td>17.5<\/td>\n<td>13.2<\/td>\n<td>8.5<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>G3\/8<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>16.8<\/td>\n<td>10<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>G1\/2<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>21<\/td>\n<td>10<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>G3\/4<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>26.5<\/td>\n<td>10<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>NPT1\/8<\/td>\n<td>\u22651200<\/td>\n<td>17<\/td>\n<td>10.2<\/td>\n<td>8<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>NPT1\/4<\/td>\n<td>\u22651500<\/td>\n<td>17.5<\/td>\n<td>13.7<\/td>\n<td>8.5<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>NPT3\/8<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>17.1<\/td>\n<td>10<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>NPT1\/2<\/td>\n<td>\u22651700<\/td>\n<td>19<\/td>\n<td>21.3<\/td>\n<td>10<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>NPT3\/4<\/td>\n<td>\u22652500<\/td>\n<td>22<\/td>\n<td>26.8<\/td>\n<td>10<\/td>\n<td>30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Selection Guide<\/h2>\n<p>Match the required thread form and pitch, minimum airflow, and installation space to the table. State the complete specification and quantity in an inquiry.<\/p>\n<h2>Dimension<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/nickel-plated-brass-waterproof-breathable-vent-plugs-dimension.webp\" alt=\"Nickel-Plated Brass Waterproof Breathable Vent Plugs dimension drawing\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Nickel-Plated Brass Waterproof Breathable Vent Plugs provide a threaded vent fitting for enclosure openings.<\/p>\n<ul>\n<li>Metric, G and NPT thread specifications with individual airflow and dimension values.<\/li>\n<li>Minimum air permeability \u2265200 to \u226518000 mL\/min at 70 mbar, depending on specification.<\/li>\n<li>Nickel-plated brass construction; catalog-listed IP68.<\/li>\n<li>Total length H, thread diameter, thread length GL and wrench dimension AG are listed for selection.<\/li>\n<\/ul>","protected":false},"featured_media":2137,"template":"","meta":[],"product_brand":[],"product_cat":[143],"product_tag":[],"class_list":["post-1016","product","type-product","status-publish","has-post-thumbnail","product_cat-enclosure-vent-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/1016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/2137"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=1016"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=1016"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=1016"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=1016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}