{"id":1525,"date":"2026-10-01T15:16:44","date_gmt":"2026-10-01T15:16:44","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1525"},"modified":"2026-10-01T15:16:52","modified_gmt":"2026-10-01T15:16:52","slug":"sep4041-7550-busbar-support-insulators","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/sep4041-7550-busbar-support-insulators\/","title":{"rendered":"SEP4041\u20137550 Busbar Support Insulators"},"content":{"rendered":"<h2>Descripci\u00f3n general<\/h2>\n<p>YOCL ELECTRIC SEP4041\u20137550 busbar support insulators provide insulated mechanical support for busbars. The insulating body is described as glass-fibre-reinforced unsaturated polyester moulding compound, with BMC or SMC configurations and metal threaded inserts.<\/p>\n<p>This series covers 10 base models with heights of 40\u201375 mm. The supplied specifications list 28 matched thread configurations. Select the thread diameter, depth and torque strength from the same row.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Moulded insulating body with threaded inserts for busbar support mounting.<\/li>\n<li>10 distinct base models with heights of 40\u201375 mm.<\/li>\n<li>BMC or SMC material configurations.<\/li>\n<li>Model-specific voltage withstand and tensile strength.<\/li>\n<li>Thread diameter, depth and torque strength paired by configuration.<\/li>\n<li>Colour, inserts, material properties and thread specifications can be requested.<\/li>\n<\/ul>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Serie<\/td>\n<td>SEP4041\u20137550<\/td>\n<\/tr>\n<tr>\n<td>Funci\u00f3n<\/td>\n<td>Insulated mechanical support for busbars<\/td>\n<\/tr>\n<tr>\n<td>Insulating body<\/td>\n<td>Glass-fibre-reinforced unsaturated polyester BMC or SMC<\/td>\n<\/tr>\n<tr>\n<td>BMC<\/td>\n<td>Bulk Moulding Compound<\/td>\n<\/tr>\n<tr>\n<td>SMC<\/td>\n<td>Sheet Moulding Compound<\/td>\n<\/tr>\n<tr>\n<td>Inserts<\/td>\n<td>Brass; other insert specifications on request<\/td>\n<\/tr>\n<tr>\n<td>Color<\/td>\n<td>Red as illustrated; other colours on request<\/td>\n<\/tr>\n<tr>\n<td>Height range<\/td>\n<td>40\u201375 mm<\/td>\n<\/tr>\n<tr>\n<td>Nominal thread diameters<\/td>\n<td>6, 8, 10, 12, 16 mm; use the listed configurations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Electrical and Mechanical Data<\/h3>\n<table>\n<thead>\n<tr>\n<th>Base model<\/th>\n<th>Tensile strength (lbf)<\/th>\n<th>Voltage withstand (kV)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SEP4041<\/td>\n<td>800<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>SEP4046<\/td>\n<td>1000<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>SEP4546<\/td>\n<td>1000<\/td>\n<td>15.5<\/td>\n<\/tr>\n<tr>\n<td>SEP5036<\/td>\n<td>900<\/td>\n<td>15.5<\/td>\n<\/tr>\n<tr>\n<td>SEP5046<\/td>\n<td>1100<\/td>\n<td>15.5<\/td>\n<\/tr>\n<tr>\n<td>SEP5050<\/td>\n<td>1500<\/td>\n<td>15.5<\/td>\n<\/tr>\n<tr>\n<td>SEP6060<\/td>\n<td>2000<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td>SEP6541<\/td>\n<td>1000<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>SEP7060<\/td>\n<td>2000<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP7550<\/td>\n<td>1500<\/td>\n<td>28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Thread Configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>Base model<\/th>\n<th>Nominal thread diameter (mm)<\/th>\n<th>Thread depth (mm)<\/th>\n<th>Torque strength (ft\u00b7lbf)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SEP4041<\/td>\n<td>8<\/td>\n<td>10<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP4041<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP4041<\/td>\n<td>12<\/td>\n<td>10<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP4046<\/td>\n<td>8<\/td>\n<td>10<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP4046<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP4046<\/td>\n<td>12<\/td>\n<td>12<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP4546<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP4546<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP4546<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP5036<\/td>\n<td>6<\/td>\n<td>15<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>SEP5036<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP5036<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP5046<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP5050<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP5050<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP5050<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP6060<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP6060<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP6060<\/td>\n<td>12<\/td>\n<td>20<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP6541<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP6541<\/td>\n<td>10<\/td>\n<td>20<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP6541<\/td>\n<td>12<\/td>\n<td>20<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP7060<\/td>\n<td>10<\/td>\n<td>20<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP7060<\/td>\n<td>12<\/td>\n<td>20<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>SEP7060<\/td>\n<td>16<\/td>\n<td>25<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>SEP7550<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>SEP7550<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP7550<\/td>\n<td>12<\/td>\n<td>20<\/td>\n<td>85<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Voltage values are the listed withstand figures, not a specified continuous operating voltage. Torque strength values are not recommended installation tightening torques. Test conditions and duration are not provided.<\/p>\n<h2>Dimensi\u00f3n<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sep4041-7550-busbar-support-insulators-dimension.webp\" alt=\"SEP4041\u20137550 Busbar Support Insulators dimension drawing\"><\/p>\n<table>\n<thead>\n<tr>\n<th>Base model<\/th>\n<th>Overall height (mm)<\/th>\n<th>Central band height (mm)<\/th>\n<th>Marked diameter \u03c6 (mm)<\/th>\n<th>Hexagon dimension (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SEP4041<\/td>\n<td>40<\/td>\n<td>12<\/td>\n<td>34<\/td>\n<td>41<\/td>\n<\/tr>\n<tr>\n<td>SEP4046<\/td>\n<td>40<\/td>\n<td>12<\/td>\n<td>40<\/td>\n<td>46<\/td>\n<\/tr>\n<tr>\n<td>SEP4546<\/td>\n<td>45<\/td>\n<td>13<\/td>\n<td>39.5<\/td>\n<td>46<\/td>\n<\/tr>\n<tr>\n<td>SEP5036<\/td>\n<td>50<\/td>\n<td>12<\/td>\n<td>29<\/td>\n<td>36<\/td>\n<\/tr>\n<tr>\n<td>SEP5046<\/td>\n<td>50<\/td>\n<td>10<\/td>\n<td>37<\/td>\n<td>46<\/td>\n<\/tr>\n<tr>\n<td>SEP5050<\/td>\n<td>50<\/td>\n<td>15<\/td>\n<td>45<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>SEP6060<\/td>\n<td>60<\/td>\n<td>15<\/td>\n<td>49.5<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>SEP6541<\/td>\n<td>65<\/td>\n<td>12<\/td>\n<td>32<\/td>\n<td>41<\/td>\n<\/tr>\n<tr>\n<td>SEP7060<\/td>\n<td>70<\/td>\n<td>14<\/td>\n<td>52<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>SEP7550<\/td>\n<td>75<\/td>\n<td>16<\/td>\n<td>38.5<\/td>\n<td>50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The diameter and hexagonal\/plan dimensions are separate drawing labels and are not interchangeable. Dimensions are transcribed from the supplied labels; no tolerances or thread pitches are specified.<\/p>\n<p>The SEP base code identifies the height and hexagon dimension. The source uses a final square placeholder for the thread dimension. The tables retain the base code and show the thread separately so the complete requested configuration can be specified without assuming a suffix format.<\/p>\n<h2>Gu\u00eda de selecci\u00f3n<\/h2>\n<p>Select the base model by its height and hexagon dimension, then choose a listed thread configuration. SEP5046 lists only a 10 mm nominal thread diameter. SEP7060 lists 10, 12 and 16 mm configurations with different torque strength and thread depth values.<\/p>\n<h2>Informaci\u00f3n de pedido<\/h2>\n<p>For a quotation, specify the SEP base model and listed nominal thread diameter, required quantity, thread form, insert material, insulating material and colour. Custom configurations for colour, inserts, material properties and threads can be requested.<\/p>","protected":false},"excerpt":{"rendered":"<p>SEP4041\u20137550 busbar support insulators provide insulated mechanical support for busbars using a moulded body and threaded metal inserts.<\/p>\n<ul>\n<li>10 base models; heights from 40 to 75 mm.<\/li>\n<li>Poli\u00e9ster insaturado BMC o SMC reforzado con fibra de vidrio.<\/li>\n<li>Nominal thread diameters: 6, 8, 10, 12, 16 mm, depending on configuration.<\/li>\n<li>Model-specific voltage withstand and tensile strength.<\/li>\n<li>Thread depth and torque strength listed together for each configuration.<\/li>\n<\/ul>","protected":false},"featured_media":1523,"template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":["post-1525","product","type-product","status-publish","has-post-thumbnail","product_cat-busbar-supports-insulators","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/1525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/1523"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=1525"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=1525"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=1525"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=1525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}