{"id":1970,"date":"2026-10-03T15:25:59","date_gmt":"2026-10-03T15:25:59","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1970"},"modified":"2026-10-03T15:26:07","modified_gmt":"2026-10-03T15:26:07","slug":"ip66-double-door-wall-mount-electrical-enclosure","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/ip66-double-door-wall-mount-electrical-enclosure\/","title":{"rendered":"IP66 Double-Door Wall-Mount Electrical Enclosure"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>The YOCL ELECTRIC IP66 Double-Door Wall-Mount Electrical Enclosure provides a steel housing for larger electrical, control and automation panels. Its cold-rolled steel body and double front doors provide access across a wide front opening, while an internal mounting plate supports the installation of panel components.<\/p>\n<p>The MED series offers 21 standard size configurations, from 1000 \u00d7 1000 \u00d7 250 mm to 1600 \u00d7 1200 \u00d7 400 mm in height \u00d7 width \u00d7 depth. Each listed enclosure includes a bar-lock closure, polyurethane door seal, cable gland plate, gasket and installation accessories.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Double front doors:<\/strong> Provide front access for larger and wider control-panel layouts.<\/li>\n<li><strong>IP66 and IK10 ratings:<\/strong> The specified protection is IP66 to EN 60529, with IK10 external mechanical impact resistance.<\/li>\n<li><strong>Cold-rolled steel construction:<\/strong> Both the enclosure body and front doors use steel with a textured epoxy polyester powder-coated finish.<\/li>\n<li><strong>Mounting plate options:<\/strong> Galvanized steel or plain steel with a smooth RAL 2004 finish.<\/li>\n<li><strong>Bar-lock closure:<\/strong> Three or four locks are specified for each model, according to enclosure height.<\/li>\n<li><strong>Dedicated cable-entry plate:<\/strong> All listed models use a cable gland plate with a type G opening.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Brand<\/td>\n<td>YOCL EL\u00c9CTRICO<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Double-door electrical \/ control enclosure<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>MED<\/td>\n<\/tr>\n<tr>\n<td>Mounting type<\/td>\n<td>Wall mount<\/td>\n<\/tr>\n<tr>\n<td>Door configuration<\/td>\n<td>Double front doors<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td>IP66<\/td>\n<\/tr>\n<tr>\n<td>IP standard<\/td>\n<td>EN 60529<\/td>\n<\/tr>\n<tr>\n<td>Impact resistance<\/td>\n<td>IK10<\/td>\n<\/tr>\n<tr>\n<td>Body and front door material<\/td>\n<td>Cold-rolled steel<\/td>\n<\/tr>\n<tr>\n<td>Surface treatment<\/td>\n<td>Textured epoxy polyester powder coating<\/td>\n<\/tr>\n<tr>\n<td>Standard body colors<\/td>\n<td>RAL 7035 \/ RAL 7032<\/td>\n<\/tr>\n<tr>\n<td>Mounting plate<\/td>\n<td>Galvanized steel or plain steel with RAL 2004 smooth finish<\/td>\n<\/tr>\n<tr>\n<td>Door seal<\/td>\n<td>Polyurethane<\/td>\n<\/tr>\n<tr>\n<td>Door closure<\/td>\n<td>Bar lock<\/td>\n<\/tr>\n<tr>\n<td>Number of locks<\/td>\n<td>3 for listed 1000\u20131200 mm high models; 4 for listed 1400\u20131600 mm high models<\/td>\n<\/tr>\n<tr>\n<td>Cable entry<\/td>\n<td>Cable gland plate<\/td>\n<\/tr>\n<tr>\n<td>Gland opening<\/td>\n<td>Type G for all listed models<\/td>\n<\/tr>\n<tr>\n<td>Standard size configurations<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td>Height range<\/td>\n<td>1000\u20131600 mm<\/td>\n<\/tr>\n<tr>\n<td>Width range<\/td>\n<td>1000\u20131200 mm<\/td>\n<\/tr>\n<tr>\n<td>Depth range<\/td>\n<td>250\u2013400 mm<\/td>\n<\/tr>\n<tr>\n<td>Included components<\/td>\n<td>Enclosure body and double doors, internal mounting plate, bar-lock system, polyurethane door seal, cable gland plate, gasket and installation accessories<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>Dimensions are stated as <strong>H \u00d7 W \u00d7 D<\/strong>, in millimeters: <strong>H = height, W = width, D = depth<\/strong>. The table lists the available standard configurations.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>H (mm)<\/th>\n<th>W (mm)<\/th>\n<th>D (mm)<\/th>\n<th>No. of Locks<\/th>\n<th>Gland Opening<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>MED10010025<\/td>\n<td>1000<\/td>\n<td>1000<\/td>\n<td>250<\/td>\n<td>3<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED12010025<\/td>\n<td>1200<\/td>\n<td>1000<\/td>\n<td>250<\/td>\n<td>3<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED12010030<\/td>\n<td>1200<\/td>\n<td>1000<\/td>\n<td>300<\/td>\n<td>3<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED12010035<\/td>\n<td>1200<\/td>\n<td>1000<\/td>\n<td>350<\/td>\n<td>3<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED12010040<\/td>\n<td>1200<\/td>\n<td>1000<\/td>\n<td>400<\/td>\n<td>3<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14010025<\/td>\n<td>1400<\/td>\n<td>1000<\/td>\n<td>250<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14010030<\/td>\n<td>1400<\/td>\n<td>1000<\/td>\n<td>300<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14010035<\/td>\n<td>1400<\/td>\n<td>1000<\/td>\n<td>350<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14010040<\/td>\n<td>1400<\/td>\n<td>1000<\/td>\n<td>400<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14012025<\/td>\n<td>1400<\/td>\n<td>1200<\/td>\n<td>250<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14012030<\/td>\n<td>1400<\/td>\n<td>1200<\/td>\n<td>300<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14012035<\/td>\n<td>1400<\/td>\n<td>1200<\/td>\n<td>350<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED14012040<\/td>\n<td>1400<\/td>\n<td>1200<\/td>\n<td>400<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16010025<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>250<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16010030<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>300<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16010035<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>350<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16010040<\/td>\n<td>1600<\/td>\n<td>1000<\/td>\n<td>400<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16012025<\/td>\n<td>1600<\/td>\n<td>1200<\/td>\n<td>250<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16012030<\/td>\n<td>1600<\/td>\n<td>1200<\/td>\n<td>300<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16012035<\/td>\n<td>1600<\/td>\n<td>1200<\/td>\n<td>350<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<tr>\n<td>MED16012040<\/td>\n<td>1600<\/td>\n<td>1200<\/td>\n<td>400<\/td>\n<td>4<\/td>\n<td>G<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Selection Guide<\/h2>\n<p>Select the complete MED model from the dimension table to match the required height, width and depth. The series ranges summarize the listed configurations; the table identifies the specific combinations available.<\/p>\n<p>Specify the body color and mounting plate finish when requesting a quotation. All listed models have double doors and a type G gland opening; the number of locks is shown against each model.<\/p>\n<h2>Aplicaciones<\/h2>\n<ul>\n<li>Larger electrical control panels.<\/li>\n<li>Industrial automation and PLC panels.<\/li>\n<li>Machinery and motor control systems.<\/li>\n<li>Power distribution and process control equipment.<\/li>\n<\/ul>\n<h2>Ordering Information<\/h2>\n<p>For a quotation, provide the MED model, quantity, preferred body color (RAL 7035 or RAL 7032) and mounting plate option (galvanized steel or plain steel with a smooth RAL 2004 finish).<\/p>","protected":false},"excerpt":{"rendered":"<p>The YOCL ELECTRIC IP66 Double-Door Wall-Mount Electrical Enclosure is a cold-rolled steel cabinet for larger electrical, control and automation panels. The MED series includes 21 standard size configurations with double front doors and an internal mounting plate.<\/p>\n<ul>\n<li>IP66 to EN 60529 and IK10 impact resistance.<\/li>\n<li>Heights of 1000\u20131600 mm, widths of 1000\u20131200 mm and depths of 250\u2013400 mm; select from the listed models.<\/li>\n<li>Textured epoxy polyester powder coating in RAL 7035 or RAL 7032.<\/li>\n<li>Polyurethane door seals, bar-lock closure and a cable gland plate with type G opening.<\/li>\n<\/ul>","protected":false},"featured_media":1969,"template":"","meta":[],"product_brand":[],"product_cat":[50],"product_tag":[],"class_list":["post-1970","product","type-product","status-publish","has-post-thumbnail","product_cat-waterproof-enclosures","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/1970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/1969"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=1970"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=1970"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=1970"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=1970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}