{"id":2652,"date":"2026-10-07T08:15:49","date_gmt":"2026-10-07T08:15:49","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2652"},"modified":"2026-10-07T08:15:58","modified_gmt":"2026-10-07T08:15:58","slug":"yc013-one-side-entry-terminal-blocks","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/yc013-one-side-entry-terminal-blocks\/","title":{"rendered":"Bloques de terminales de entrada unilateral YC013"},"content":{"rendered":"<h2>Descripci\u00f3n general<\/h2>\n<p>YOCL ELECTRIC YC013 One-Side Entry Terminal Blocks provide electrical wire connections. One-side entry strips in 5\u00d71 and 10\u00d71 layouts, with 500 V ratings.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>YC013 One-Side Entry Terminal Blocks construction with Polycarbonate (PC) housing.<\/li>\n<li>Inserciones conductoras de lat\u00f3n.<\/li>\n<li>Temperatura de funcionamiento: \u221235\u00b0C a +120\u00b0C.<\/li>\n<li>Pole configurations: 5 \/ 10.<\/li>\n<\/ul>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9CTRICO<\/td>\n<\/tr>\n<tr>\n<td>Familia de productos<\/td>\n<td>Bloques de terminales de entrada unilateral YC013<\/td>\n<\/tr>\n<tr>\n<td>Material de la carcasa<\/td>\n<td>Policarbonato (PC)<\/td>\n<\/tr>\n<tr>\n<td>Inserto conductor<\/td>\n<td>Lat\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Material del tornillo<\/td>\n<td>Acero zincado<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de trabajo<\/td>\n<td>\u221235\u00b0C a +120\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Configuraciones de polos<\/td>\n<td>5 \/ 10<\/td>\n<\/tr>\n<tr>\n<td>Colores indicados<\/td>\n<td>Transparente<\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n nominal<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>Clasificaciones y embalaje del modelo<\/td>\n<td>Consulte la tabla de modelos; cada fila se aplica \u00fanicamente a ese modelo.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calificaciones y embalaje del modelo<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Wire range (mm\u00b2)<\/th>\n<th>Tensi\u00f3n nominal (V)<\/th>\n<th>Polos<\/th>\n<th>Tama\u00f1o del tornillo<\/th>\n<th>Unidades por caja<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YC013-01<\/td>\n<td>1.5<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M3.0<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-02<\/td>\n<td>2.5<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M3.5<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-03<\/td>\n<td>4.0<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M3.5<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-04<\/td>\n<td>6.0<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M4.0<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-05<\/td>\n<td>10<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M5.0<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>YC013-06<\/td>\n<td>16<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M8.0<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>YC013-07<\/td>\n<td>25<\/td>\n<td>500<\/td>\n<td>5<\/td>\n<td>M10.0<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>YC013-08<\/td>\n<td>1.5<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M3.0<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-09<\/td>\n<td>2.5<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M3.5<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-10<\/td>\n<td>4.0<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M3.5<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-11<\/td>\n<td>6.0<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M4.0<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>YC013-12<\/td>\n<td>10<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M5.0<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>YC013-13<\/td>\n<td>16<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M8.0<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>YC013-14<\/td>\n<td>25<\/td>\n<td>500<\/td>\n<td>10<\/td>\n<td>M10.0<\/td>\n<td>100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensi\u00f3n<\/h2>\n<p>Todos los valores de las dimensiones est\u00e1n en mm. Las letras y los s\u00edmbolos de di\u00e1metro identifican las dimensiones correspondientes.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>L (mm)<\/th>\n<th>An (mm)<\/th>\n<th>A (mm)<\/th>\n<th>E (mm)<\/th>\n<th>\u00d8 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YC013-01<\/td>\n<td>46<\/td>\n<td>15.3<\/td>\n<td>15.5<\/td>\n<td>9.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>YC013-02<\/td>\n<td>50<\/td>\n<td>17.5<\/td>\n<td>17.3<\/td>\n<td>10.1<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>YC013-03<\/td>\n<td>59<\/td>\n<td>20<\/td>\n<td>18.7<\/td>\n<td>11.95<\/td>\n<td>4.2<\/td>\n<\/tr>\n<tr>\n<td>YC013-04<\/td>\n<td>69<\/td>\n<td>22.8<\/td>\n<td>22.8<\/td>\n<td>14<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>YC013-05<\/td>\n<td>83.5<\/td>\n<td>26.8<\/td>\n<td>26.6<\/td>\n<td>16.9<\/td>\n<td>7.7<\/td>\n<\/tr>\n<tr>\n<td>YC013-06<\/td>\n<td>110.5<\/td>\n<td>30.9<\/td>\n<td>33.5<\/td>\n<td>22.3<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>YC013-07<\/td>\n<td>121.5<\/td>\n<td>38.3<\/td>\n<td>41.6<\/td>\n<td>24.5<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>YC013-08<\/td>\n<td>92<\/td>\n<td>15.3<\/td>\n<td>15.5<\/td>\n<td>9.3<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>YC013-09<\/td>\n<td>100<\/td>\n<td>17.5<\/td>\n<td>17.3<\/td>\n<td>10.1<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>YC013-10<\/td>\n<td>118<\/td>\n<td>20<\/td>\n<td>18.7<\/td>\n<td>11.95<\/td>\n<td>4.2<\/td>\n<\/tr>\n<tr>\n<td>YC013-11<\/td>\n<td>137.9<\/td>\n<td>22.8<\/td>\n<td>22.8<\/td>\n<td>14<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>YC013-12<\/td>\n<td>167<\/td>\n<td>26.8<\/td>\n<td>26.6<\/td>\n<td>16.9<\/td>\n<td>7.7<\/td>\n<\/tr>\n<tr>\n<td>YC013-13<\/td>\n<td>221<\/td>\n<td>30.9<\/td>\n<td>33.5<\/td>\n<td>22.3<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>YC013-14<\/td>\n<td>243<\/td>\n<td>38.3<\/td>\n<td>41.6<\/td>\n<td>24.5<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/yc013-one-side-entry-terminal-blocks-dimension.webp\" alt=\"YC013 One-Side Entry Terminal Blocks dimension drawing\"><\/p>\n<h2>Gu\u00eda de selecci\u00f3n<\/h2>\n<p>Seleccione el modelo exacto por secci\u00f3n transversal del conductor y la potencia el\u00e9ctrica en su fila. Verifique la configuraci\u00f3n de polos requerida y las dimensiones juntas; las potencias de diferentes modelos no son intercambiables.<\/p>\n<h2>Informaci\u00f3n de pedido<\/h2>\n<p>Especifique el modelo, la secci\u00f3n transversal del conductor, la configuraci\u00f3n requerida y la cantidad. Indique la unidad de embalaje al realizar el pedido.<\/p>","protected":false},"excerpt":{"rendered":"<p>YC013 One-Side Entry Terminal Blocks from YOCL ELECTRIC. One-side entry strips in 5\u00d71 and 10\u00d71 layouts, with 500 V ratings.<\/p>\n<ul>\n<li>Electrical ratings: 500 V; see the selected model.<\/li>\n<li>Inserciones conductoras de lat\u00f3n.<\/li>\n<li>Temperatura de funcionamiento: \u221235\u00b0C a +120\u00b0C.<\/li>\n<li>Pole configurations: 5 \/ 10.<\/li>\n<\/ul>","protected":false},"featured_media":2650,"template":"","meta":[],"product_brand":[],"product_cat":[22],"product_tag":[],"class_list":["post-2652","product","type-product","status-publish","has-post-thumbnail","product_cat-terminal-strips-barrier-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/2652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/2650"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=2652"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=2652"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=2652"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=2652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}