{"id":2846,"date":"2026-10-07T13:33:13","date_gmt":"2026-10-07T13:33:13","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2846"},"modified":"2026-10-07T13:35:45","modified_gmt":"2026-10-07T13:35:45","slug":"ip44-industrial-appliance-inlets","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/ip44-industrial-appliance-inlets\/","title":{"rendered":"IP44 Conectores para electrodom\u00e9sticos industriales"},"content":{"rendered":"<h2>Descripci\u00f3n general<\/h2>\n<p>Las entradas para aparatos industriales YOCL ELECTRIC IP44 proporcionan una conexi\u00f3n de alimentaci\u00f3n macho en maquinaria, equipos de distribuci\u00f3n y carcasas de equipos. La familia cubre versiones 16 A y 32 A en configuraciones 2P+E, 3P+E y 3P+N+E. Las entradas rectas para panel y los dise\u00f1os de entrada en superficie cerrados se agrupan aqu\u00ed para que la interfaz de suministro pueda seleccionarse junto con su disposici\u00f3n de montaje. Un conector de cable hembra a juego proporciona la conexi\u00f3n de cable desmontable.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Versiones IP44 para conexiones industriales protegidas contra salpicaduras.<\/li>\n<li>Dise\u00f1os rectos para panel en carcasas est\u00e1ndar y K, adem\u00e1s de dise\u00f1os en superficie con una cara de conector en \u00e1ngulo.<\/li>\n<li>Opciones 16 A y 32 A con rangos de conductor indicados para cada modelo.<\/li>\n<li>Posici\u00f3n de contacto de tierra 6h en los modelos listados.<\/li>\n<li>Las carcasas de contacto azules y rojas distinguen las configuraciones el\u00e9ctricas listadas.<\/li>\n<\/ul>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9CTRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de producto<\/td>\n<td>Entrada para aparatos industriales \/ entrada macho para equipos<\/td>\n<\/tr>\n<tr>\n<td>Grado de protecci\u00f3n<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Opciones de corriente nominal<\/td>\n<td>16 A, 32 A<\/td>\n<\/tr>\n<tr>\n<td>Configuraciones de contacto<\/td>\n<td>2P+E; 3P+E; 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Posici\u00f3n de contacto a tierra<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Montaje<\/td>\n<td>Montaje en panel o montaje superficial con carcasa, seg\u00fan el modelo<\/td>\n<\/tr>\n<tr>\n<td>Interfaz de cable de acoplamiento<\/td>\n<td>Conector de cable industrial hembra a juego<\/td>\n<\/tr>\n<tr>\n<td>Capacidad del conductor<\/td>\n<td>Espec\u00edfico del modelo; consulte la tabla de selecci\u00f3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Selecci\u00f3n de modelo<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Montaje \/ carcasa<\/th>\n<th>Corriente (A)<\/th>\n<th>Contactos<\/th>\n<th>Voltaje<\/th>\n<th>Posici\u00f3n de tierra<\/th>\n<th>Carcasa de contacto<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Rojo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>P denotes a phase contact, N neutral and E protective earth. A dash means that no voltage is assigned in this selection table.<\/p>\n<h2>Dimensi\u00f3n<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Lettered outline dimensions (mm)<\/th>\n<th>Fixed mounting geometry<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use the lettered dimensions with the matching inlet outline. Flange geometry and housing size differ between body versions; select the complete model code when checking installation space.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-02.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-03.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<h2>Selecci\u00f3n de conexi\u00f3n<\/h2>\n<p>Match rated current, contact configuration, voltage and earth-contact position at both sides of the connection. Select panel or surface mounting before comparing the housing dimensions. The IP rating applies to the correctly assembled connection with its compatible mating interface; maintain the specified sealing and closure arrangement.<\/p>\n<h2>Informaci\u00f3n de pedido<\/h2>\n<p>Send YOCL ELECTRIC the full model code, required quantity, supply voltage, contact configuration and installation arrangement. Include conductor cross-section and the mating cable connector when requesting a complete equipment power connection.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 entradas para aparatos industriales en versiones 16 A y 32 A. Elija contactos 2P+E, 3P+E o 3P+N+E, montaje en panel o en superficie y la capacidad de conductor correspondiente en la tabla de modelos.<\/p>","protected":false},"featured_media":2845,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2846","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/2845"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=2846"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=2846"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}