{"id":2856,"date":"2026-10-07T13:58:16","date_gmt":"2026-10-07T13:58:16","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2856"},"modified":"2026-10-07T13:58:26","modified_gmt":"2026-10-07T13:58:26","slug":"ip44-industrial-cable-couplers","status":"publish","type":"product","link":"https:\/\/yocl.com\/es\/product\/ip44-industrial-cable-couplers\/","title":{"rendered":"IP44 Acopladores de Cable Industriales"},"content":{"rendered":"<h2>Descripci\u00f3n general<\/h2>\n<p>Los acopladores de cable industriales YOCL ELECTRIC IP44 son conectores de cable hembra para conexiones de cable industriales. Esta familia re\u00fane los modelos 16 A y 32 A actuales que se enumeran a continuaci\u00f3n, con configuraciones de contactos 2P+E, 3P+E y 3P+N+E. Cada modelo tiene su propia tensi\u00f3n, posici\u00f3n horaria del contacto de tierra y dise\u00f1o de carcasa.<\/p>\n<p>El extremo del conector tiene contactos hembra y una tapa frontal protectora; la entrada trasera acepta el cable de alimentaci\u00f3n. Las versiones con dise\u00f1o H, dise\u00f1o K, cuerpo trasero blanco y posici\u00f3n horaria especial permanecen en grupos de modelos separados para que la fotograf\u00eda de la carcasa y los datos dimensionales puedan coincidir con el conector correcto.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>IP44 \u00edndice de protecci\u00f3n para los modelos listados.<\/li>\n<li>Contactos hembra y una tapa protectora para el extremo del conector de cable.<\/li>\n<li>Opciones de corriente nominal: 16 A y 32 A; las combinaciones reales se definen en las tablas de modelos.<\/li>\n<li>Las versiones 2P+E, 3P+E y 3P+N+E se identifican individualmente.<\/li>\n<li>Dise\u00f1os de contacto de tierra: 4h, 6h y 9h seleccionados, seg\u00fan el modelo especificado.<\/li>\n<li>Los grupos de carcasas independientes conservan la capacidad de conductor y los datos dimensionales de cada modelo.<\/li>\n<\/ul>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9CTRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de producto<\/td>\n<td>Conectores de cable hembra<\/td>\n<\/tr>\n<tr>\n<td>Montaje<\/td>\n<td>Montaje en cable<\/td>\n<\/tr>\n<tr>\n<td>Grado de protecci\u00f3n<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Corrientes nominales<\/td>\n<td>16 A y 32 A<\/td>\n<\/tr>\n<tr>\n<td>Disposiciones de contactos<\/td>\n<td>2P+E (3 contactos); 3P+E (4 contactos); 3P+N+E (5 contactos)<\/td>\n<\/tr>\n<tr>\n<td>Posiciones de contacto a tierra<\/td>\n<td>4h, 6h y 9h seleccionados<\/td>\n<\/tr>\n<tr>\n<td>Configuraciones de tensi\u00f3n<\/td>\n<td>Consulte las filas de modelos individuales; se conservan las clasificaciones emparejadas de cinco contactos seg\u00fan lo indicado.<\/td>\n<\/tr>\n<tr>\n<td>Capacidades de los conductores<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dise\u00f1o de carcasa H \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Printed reference<\/th>\n<th>Corriente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tensi\u00f3n (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>514<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>526<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>NM5<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>NM6<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dise\u00f1o de carcasa K \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corriente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tensi\u00f3n (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dise\u00f1os de cuerpo trasero blanco \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corriente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tensi\u00f3n (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarillo<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Disposiciones de contacto especiales de 9h \u2014 16 \/ 32 A<\/h2>\n<p>These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corriente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tensi\u00f3n (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213L-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-223L-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Rojo<\/td>\n<\/tr>\n<tr>\n<td>NM-214L-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-224L-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Azul<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensi\u00f3n<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Dise\u00f1o de carcasa H \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>a = 156.5; b = 51.3; c = 61.2<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>a = 161.7; b = 50.2; c = 69<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>a = 200; b = 70.8; c = 79.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Dise\u00f1o de carcasa K \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>a = 143; b = 80; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>a = 150; b = 82; c = 64<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>a = 167; b = 97; c = 72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Dise\u00f1os de cuerpo trasero blanco \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>a = 131; b = 79; c = 56; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>a = 141; b = 93; c = 64; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>a = 154; b = 101; c = 71; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-02.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-03.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-04.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-05.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<h2>Gu\u00eda de selecci\u00f3n<\/h2>\n<p>Choose a female cable coupler when the mating connection is made at the end of a cable. A wall-mounted socket or an appliance inlet belongs to a different mounting and contact family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Informaci\u00f3n de pedido<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP44 industrial cable couplers, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 acopladores de cable industriales para conexiones de extremo de cable, con dise\u00f1os de carcasa distintos y tablas completas de selecci\u00f3n de modelos NM.<\/p>\n<ul>\n<li>Corrientes nominales: 16 A y 32 A.<\/li>\n<li>Contactos: 2P+E, 3P+E y 3P+N+E.<\/li>\n<li>Disposiciones de contacto de tierra 4h, 6h y 9h seleccionadas, seg\u00fan el modelo.<\/li>\n<li>Conector de cable hembra con tapa frontal.<\/li>\n<li>Seleccione voltaje, capacidad del conductor y dimensiones mediante el c\u00f3digo de modelo completo.<\/li>\n<\/ul>","protected":false},"featured_media":2850,"template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":["post-2856","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-couplers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product\/2856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media\/2850"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/media?parent=2856"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_brand?post=2856"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_cat?post=2856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/es\/wp-json\/wp\/v2\/product_tag?post=2856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}