TB Series Plate-Screw Terminal Blocks

YOCL ELECTRIC TB Series Plate-Screw Terminal Blocks provide wire termination for industrial control and power distribution systems.

  • 24 TB and TBC models, rated 600 V.
  • Model-specific current ratings: 15 A, 25 A, 45 A, 60 A and 100 A.
  • Listed conductor ranges span 0.5–6 mm², depending on model.
  • Plate-type screw clamping for OT and UT terminals.
  • Closed construction, protective dust covers and clear PVC markings.
Renseignez-vous sur ce produit

Aperçu

YOCL ELECTRIC TB Series Plate-Screw Terminal Blocks connect conductors in industrial control and distribution systems. The closed, integrated construction uses plate-type screw clamping with OT and UT terminals. The listed TB and TBC models are rated 600 V, with individual current ratings from 15 A to 100 A.

Caractéristiques

  • Plate-type screw clamping for OT and UT terminals.
  • Protective dust covers and clear PVC markings.
  • Five model-specific current groups.
  • Baseplate mounting provisions for panel installation.

Spécifications techniques

Parameter Specification
Brand YOCL ÉLECTRIQUE
Series TB / TBC
Connexion Plate-type screw clamping
Construction Closed, integrated structure
Rated voltage 600 V
Current ratings 15, 25, 45, 60 and 100 A, depending on model
Listed conductor ranges Model-dependent; see table
Terminal compatibility OT / UT
Listed models 24

Model Specifications

Model Rated current Listed poles Conductor range Mounting size L1 Outline dimensions L × W × H
TB-1503 15 A 3 0.5–1.5 mm² 34 mm 45.3 × 22 × 15 mm
TB-1504 15 A 4 0.5–1.5 mm² 44 mm 54.3 × 22 × 15 mm
TB-1505 15 A 5 0.5–1.5 mm² 57 mm 63.3 × 22 × 15 mm
TB-1506 15 A 6 0.5–1.5 mm² 61 mm 72 × 22 × 15 mm
TB-1510 15 A 10 0.5–1.5 mm² 96 mm 108 × 22 × 15 mm
TB-1512 15 A 12 0.5–1.5 mm² 114 mm 125 × 22 × 15 mm
TB-2503 25 A 3 0.5–2.5 mm² 44 mm 55 × 30 × 17 mm
TB-2504 25 A 4 0.5–2.5 mm² 57 mm 67 × 30 × 17 mm
TB-2505 25 A 5 0.5–2.5 mm² — 80 × 30 × 17 mm
TB-2506 25 A 6 0.5–2.5 mm² 81 mm 91 × 30 × 17 mm
TB-2510 25 A 10 0.5–2.5 mm² 129 mm 139 × 30 × 17 mm
TB-2512 25 A 10 0.5–2.5 mm² 154 mm 164.5 × 30 × 17 mm
TB-4503 45 A 3 1.5–4 mm² 58.5 mm 69.5 × 68 × 21 mm
TB-4504 45 A 4 1.5–4 mm² 75 mm 86 × 38 × 21 mm
TB-4505 45 A 5 1.5–4 mm² 91.5 mm 102.5 × 38 × 21 mm
TB-4506 45 A 6 1.5–4 mm² 108 mm 119 × 38 × 21 mm
TB-4510 45 A 10 1.5–4 mm² 174 mm 185 × 38 × 21 mm
TB-4512 45 A 12 1.5–4 mm² 207 mm 218 × 38 × 21 mm
TBC-603 60 A 3 2.5–6 mm² 60.5 mm 84.5 × 54.5 × 31.5 mm
TBC-604 60 A 4 2.5–6 mm² 82.5 mm 113 × 54.5 × 31.5 mm
TBC-605 60 A 6 2.5–6 mm² 118 mm 129 × 54.5 × 31.5 mm
TBC-1003 100 A 3 2.5–6 mm² 75.5 mm 86.5 × 43.5 × 35 mm
TBC-1004 100 A 4 2.5–6 mm² 96 mm 108 × 43.5 × 35 mm
TBC-1006 100 A 6 2.5–6 mm² 140 mm 153 × 43.5 × 35 mm

A dash indicates that the mounting value is not specified.

Selection Guide

  • Match the selected model’s current rating, conductor range and pole count to the circuit.
  • Check L1 and outline dimensions against the available panel space.
  • Specify the required OT or UT termination arrangement when ordering.

Applications

  • Industrial control panels and machinery.
  • Power distribution systems.
  • Motor control centres.
  • HVAC and building automation.

Ordering Information

Specify YOCL ÉLECTRIQUE, the TB or TBC model, circuit requirements, terminal arrangement, mounting constraints and quantity.

Détails du projet

Les champs marqués d'un * sont obligatoires.

Vos coordonnées seront utilisées pour répondre à votre demande. Notice de confidentialité