YOCL ÉLECTRIQUE

Waterproof Connection Boxes Manufacturer

IP68 mini junction boxes with 2–8 cable entries across the F1, F2, F3 and F5 ranges, plus a separate IP65 rocker switch box. Match the entry layout, cable seal and terminal rating to your application.

Explorer la gamme
YOCL waterproof connection box collection with cable entries and terminal options
IP68 junction boxes

Choose your entry layout and terminal rating.

Compare junction box specifications.

Listed ratings apply to the specified screw-terminal configurations.

ModelEntriesCurrent / voltageConductor (mm²)Cable O.D. options (mm)
F1-2T216 A / 450 V0.5–43–6.5 / 5–8 / 7–10
F1-3T316 A / 450 V0.5–2.53–6.5 / 5–8 / 7–10
F1-4T424 A / 450 V0.5–2.53–6.5 / 5–8 / 7–10
F2-3T310 A / 450 V0.5–2.55–8 / 9–12
F3-2T232 A / 450 V0.5–105–8 / 9–12 / 10–14
F3-3T332 A / 450 V0.5–105–8 / 9–12
F3-4T432 A / 450 V0.5–105–8 / 9–12
F3-5T532 A / 450 V0.5–105–8 / 9–12
F3-6T632 A / 450 V0.5–105–8 / 9–12 / 10–14
F5-3T360 A / 450 V0.5–105–8 / 9–12 / 10–14
F5-4T460 A / 450 V0.5–105–8 / 9–12 / 10–14
F5-8T860 A / 450 V0.5–105–8 / 9–12 / 10–14

F5-4T offers 2 + 2 and 3 + 1 entry layouts. F3-5T also has alternative layouts; confirm the arrangement when ordering.

IP65 switch enclosure

Waterproof rocker switch box.

IP65 Waterproof Rocker Switch Box product image

Enclose the switch and cable connections.

Two cable entries, a 22 × 31 mm switch cutout and cable seals for 3–6, 5–8 or 7–10 mm outside diameters.

Choose four-terminal / two-position or six-terminal / three-position arrangements, with the specified screw-terminal or push-on connection option. Confirm the required circuit rating and whether you need the enclosure or complete switch assembly.

View switch box
Selection essentials

Match the box to your cable connection.

01

Cable entries

Choose the number and arrangement of cable entries to suit the wiring layout.

02

Cable diameter

Match each cable’s measured outside diameter to the specified sealing range.

03

Terminal option

Confirm conductor size, connection method and the terminal configuration supplied.

04

Service conditions

Check the selected model’s temperature limits and protection data for the intended environment.

Common questions

Before you choose.

Which terminal rating should I choose?

The listed screw-terminal ratings are 16 A for F1-2T and F1-3T, 24 A for F1-4T, 10 A for F2-3T, 32 A for F3 models and 60 A for F5 models, all at 450 V. Match the exact model and conductor range to the circuit requirements.

Does every configuration have the same protection rating?

The mini junction boxes are listed as IP68; the rocker switch box is IP65. Confirm the selected configuration and test conditions. Correct cable sizing, sealing and assembly remain essential.

Are all the terminal options shown included?

The collection image shows a range of box and terminal options. Confirm the supplied terminal and accessories for the selected model before ordering.

What information is needed for a quotation?

Provide the series or drawing, cable-entry arrangement, cable diameters, conductor sizes, quantities and packaging requirements.