YOCL

RVD Double-Crimp Ring Terminal

YOCL ELECTRIC RVD Double-Crimp Ring Terminal is a copper terminal for bolted conductor connections. The 47 listed models cover 0.5–6 mm² conductor groups in red, blue and yellow.

  • Select by conductor range and bolt-hole diameter.
  • Model-specific US bolt number, d2, B, F and L values are listed in the detail table.
  • Group-specific maximum current, material thickness, E, D1 and D2 values are shown separately.
Inquire about this product

Overview

YOCL ELECTRIC RVD Double-Crimp Ring Terminal is a copper ring terminal with a PVC insulating sleeve and an additional copper tube for the double-crimp construction shown in the reference. The ring eyelet connects to a suitably sized bolt or stud, and the barrel receives the conductor. The two catalog pages list 47 RVD models in red, blue and yellow conductor groups, covering 0.5–6 mm².

Features

  • Double-crimp structure: the source identifies an insulating sleeve plus copper tube for the double-pressure design.
  • Copper terminal: the catalog identifies the conductive terminal material as copper.
  • Colour-coded groups: group colour identifies the listed conductor range.
  • Model-specific bolt fit: each model lists both a US bolt number and metric hole diameter d2.

Technical Specifications

Parameter Specification
Series RVD
Product type Double-crimp ring terminal
Terminal material Copper
PVC insulating sleeve Specified for all three listed groups
Listed models 47
Conductor ranges across listed groups 0.5–6 mm²; see group table for the available intervals
Drawing dimension units mm

The maximum current and terminal material thickness are stated by colour group, not as one rating for every model. Imax is the source’s maximum-current label.

Model group / colour Conductor range AWG Imax Material thickness E (mm) D1 (mm) D2 (mm)
RVD 1.25 / Red 0.5–1.5 mm² AWG 22–16 19 A 0.7 mm 10.0 4.3 4.5
RVD 2 / Blue 1.5–2.5 mm² AWG 16–14 27 A 0.8 mm 10.0 4.9 5.2
RVD 5.5 / Yellow 4–6 mm² AWG 12–10 48 A 1.0 mm 13.0 6.7 7.0

Dimension

The table and drawing use B, F, L, E, D1 and D2 as dimension labels. The table’s d2 is the metric bolt-hole diameter. All B, F, L, E, D1, D2 and d2 values are in millimeters; the US bolt number is a separate size designation.

Model Colour US bolt no. Hole d2 (mm) B (mm) F (mm) L (mm)
RVD 1.25-3 Red #4 3.2 5.7 4.95 17.8
RVD 1.25-3.5S Red #6 3.7 5.7 4.95 17.8
RVD 1.25-3.5M Red #6 3.7 6.6 6.3 19.6
RVD 1.25-3.5L Red #6 3.7 8.0 7.0 21.0
RVD 1.25-4S Red #8 4.3 6.6 6.3 19.6
RVD 1.25-4L Red #8 4.3 8.0 7.0 21.0
RVD 1.25-5S Red #10 5.3 8.0 7.0 21.0
RVD 1.25-5L Red #10 5.3 9.5 8.5 22.2
RVD 1.25-5LL Red #10 5.3 11.6 11.1 27.0
RVD 1.25-6S Red 1/4 6.5 9.5 8.5 22.2
RVD 1.25-6L Red 1/4 6.5 11.6 11.1 27.0
RVD 1.25-8 Red 5/16 8.5 11.6 11.1 27.0
RVD 1.25-10 Red 3/8 10.5 13.6 13.9 30.7
RVD 1.25-10L Red 3/8 10.5 19.2 16.0 35.6
RVD 1.25-12 Red 1/2 13.0 19.2 16.0 35.6
RVD 1.25-14 Red 9/16 15.0 27.0 21.0 44.5
RVD 1.25-16 Red 5/8 17.0 27.0 21.0 44.5
RVD 1.25-20 Red 3/4 21.0 27.0 21.0 44.5
RVD 2-3 Blue #4 3.2 6.6 4.3 17.7
RVD 2-3.5S Blue #6 3.7 6.6 4.3 17.7
RVD 2-3.5M Blue #6 3.7 6.6 6.3 19.7
RVD 2-3.5L Blue #6 3.7 8.5 7.4 21.7
RVD 2-4S Blue #8 4.3 6.6 6.3 19.7
RVD 2-4L Blue #8 4.3 8.5 7.4 21.7
RVD 2-5S Blue #10 5.3 8.5 7.4 21.7
RVD 2-5L Blue #10 5.3 9.5 7.4 22.2
RVD 2-6S Blue 1/4 6.5 9.5 7.4 22.2
RVD 2-6L Blue 1/4 6.5 12.0 11.0 27.0
RVD 2-8 Blue 5/16 8.5 12.0 11.0 27.0
RVD 2-10 Blue 3/8 10.5 13.6 13.9 30.7
RVD 2-10L Blue 3/8 10.5 19.2 16.0 35.6
RVD 2-12 Blue 1/2 13.0 19.2 16.0 35.6
RVD 2-14 Blue 9/16 15.0 27.0 21.0 44.5
RVD 2-16 Blue 5/8 17.0 27.0 21.0 44.5
RVD 2-20 Blue 3/4 21.0 27.0 21.0 44.5
RVD 5.5-3.5 Yellow #6 3.7 7.2 6.1 22.7
RVD 5.5-4S Yellow #8 4.3 7.2 6.1 22.7
RVD 5.5-4L Yellow #8 4.3 9.5 8.3 26.0
RVD 5.5-5 Yellow #10 5.3 9.5 8.3 26.0
RVD 5.5-6 Yellow 1/4 6.5 12.0 10.5 29.5
RVD 5.5-6M Yellow 1/4 6.5 12.0 13.0 32.0
RVD 5.5-8 Yellow 5/16 8.5 15.0 13.7 35.0
RVD 5.5-10 Yellow 3/8 10.5 15.0 13.7 35.0
RVD 5.5-12 Yellow 1/2 13.0 19.2 16.0 39.4
RVD 5.5-14 Yellow 9/16 15.0 32.0 25.2 54.2
RVD 5.5-16 Yellow 5/8 17.0 32.0 25.2 54.2
RVD 5.5-20 Yellow 3/4 21.0 32.0 25.2 54.2

The E, D1 and D2 dimensions are shown by colour group in the specification table above. The RVD column lists 1.25, 2 and 5.5 groups only; no RVD entries are shown for the other groups on these pages.

RVD Double-Crimp Ring Terminal dimension drawing

Selection Guide

Choose the conductor group first, then check the required bolt or stud size against the listed US bolt designation and actual d2 hole diameter. Compare B, F, L and the group-level sleeve dimensions with the available connection space. Use the model’s colour-group Imax value only in the context of the catalog specification; the source gives no operating conditions for that maximum.

Applications

Bolted conductor connections to compatible electrical equipment terminals.

Ordering Information

Specify the exact RVD model and quantity when requesting a quotation.

Détails du projet

Les champs marqués d'un * sont obligatoires.

Vos coordonnées seront utilisées pour répondre à votre demande. Notice de confidentialité