LSV/LSD Pre-Insulated Lock Fork Terminals

YOCL ELECTRIC LSV/LSD Pre-Insulated Lock Fork Terminals are copper terminals with PVC insulation for bolted conductor connections. The combined series lists 14 matched pairs: LSV single crimp and LSD double crimp, covering conductor groups from 0.5 to 6 mm².

  • Choose the conductor group and fork opening d2 for the intended bolt or stud.
  • Compare B, F and L by model, with E, D1 and D2 dimensions specified by group.
  • Red, blue and yellow insulation identifies the listed groups.
Renseignez-vous sur ce produit

Aperçu

YOCL ELECTRIC LSV/LSD Pre-Insulated Lock Fork Terminals are copper fork terminals with PVC insulating sleeves for bolted conductor connections. LSV identifies the single-crimp construction and LSD the double-crimp construction with an additional copper tube and sleeve described in the supplied catalog. The page lists 14 matched model pairs in three conductor groups from 0.5 to 6 mm².

Caractéristiques

  • Lock fork contact: the fork geometry shown in the catalog provides an open connection to a compatible bolt or stud.
  • Two crimp constructions: LSV and LSD model columns are paired by bolt fit and B, F and L dimensions; their barrel constructions differ.
  • Copper and PVC materials: the catalog states copper terminal material and PVC insulation for all three groups.
  • Group-specific ratings: Imax, material thickness and shared sleeve dimensions are shown by conductor group.

Spécifications techniques

Paramètre Spécification
Product type Pre-insulated lock fork terminal
Série LSV single crimp; LSD double crimp
Listed models 14 LSV and 14 LSD
Terminal material Copper
Insulation PVC
LSD construction Copper tube with sleeve, described as double pressure in the source
Drawing dimension units mm

The current figures are labelled Imax (maximum current) in the reference. Each figure applies to its own conductor group; operating conditions are not provided.

Model group Color Conductor range AWG Imax Material thickness E (mm) D1 (mm), LSV D2 (mm), LSD
LSV/LSD 1.25 Red 0.5–1.5 mm² AWG 22–16 19 A 0.7 mm 10.0 4.3 4.5
LSV/LSD 2 Blue 1.5–2.5 mm² AWG 16–14 27 A 0.8 mm 10.0 4.9 5.2
LSV/LSD 5.5 Yellow 4–6 mm² AWG 12–10 48 A 1.0 mm 13.0 6.7 7.0

Dimension

The drawing uses B, F, L and E for overall dimensions. The fork opening is d2; D1 applies to the LSV barrel and D2 to the LSD barrel. All dimensions below are in millimeters.

LSV single-crimp model LSD double-crimp model Color US bolt no. Fork opening d2 (mm) B (mm) F (mm) L (mm)
LSV 1.25-3.5 LSD 1.25-3.5 Red #6 3.7 6.4 6.5 21.2
LSV 1.25-4S LSD 1.25-4S Red #8 4.3 7.2 6.5 21.2
LSV 1.25-4L LSD 1.25-4L Red #8 4.3 8.1 6.5 21.2
LSV 1.25-5S LSD 1.25-5S Red #10 5.3 8.1 6.5 21.2
LSV 1.25-5L LSD 1.25-5L Red #10 5.3 9.5 6.5 21.2
LSV 2-3.5 LSD 2-3.5 Blue #6 3.7 6.0 6.5 21.2
LSV 2-4S LSD 2-4S Blue #8 4.3 7.2 6.5 21.2
LSV 2-4L LSD 2-4L Blue #8 4.3 8.1 6.5 21.2
LSV 2-5S LSD 2-5S Blue #10 5.3 8.1 6.5 21.2
LSV 2-5L LSD 2-5L Blue #10 5.3 9.3 6.5 21.2
LSV 5.5-3.5 LSD 5.5-3.5 Yellow #6 3.7 8.3 7.0 25.2
LSV 5.5-4 LSD 5.5-4 Yellow #8 4.3 8.3 7.0 25.2
LSV 5.5-5 LSD 5.5-5 Yellow #10 5.3 9.0 7.0 25.2
LSV 5.5-6 LSD 5.5-6 Yellow 1/4 6.4 12.0 12.0 31.5

E, D1 and D2 are shared within each conductor group in the technical specifications above. The reference drawing marks a plate thickness T but does not provide a numerical T value.

LSV/LSD Pre-Insulated Lock Fork Terminals dimension drawing

Guide de sélection

Choose LSV or LSD construction and the conductor group first. Then check fork opening d2 against the intended bolt or stud and compare B, F, L and the applicable barrel dimensions with the available connection space. Use the exact LSV or LSD model code when ordering.

Informations de commande

Specify the LSV or LSD model and quantity when requesting a quotation.

Détails du projet

Les champs marqués d'un * sont obligatoires.

Vos coordonnées seront utilisées pour répondre à votre demande. Notice de confidentialité