YOCL

Raccords à manchon thermorétractables BHT

BHT heat shrinkable butt connectors join conductors with a copper crimp sleeve and adhesive-lined PE heat shrink insulation.

  • Four models for catalog conductor ranges from 0.3–0.5 to 4.0–6.0 mm².
  • 3:1 shrink ratio; shrink begins at 80 °C and full recovery is listed at 130 °C.
  • Listed operating temperature: −55 to +125 °C.
  • Select by conductor range, copper sleeve diameter and length, finished diameter, and color.
Renseignez-vous sur ce produit

Aperçu

BHT Heat Shrinkable Butt Connectors combine a copper crimp sleeve with an adhesive-lined PE heat shrink tube for inline conductor splices. The catalog lists four sizes covering conductor cross-sections from 0.3 to 6.0 mm². The heat shrink layer is intended to insulate the joint and help protect it from moisture and corrosion.

Caractéristiques

  • Adhesive-lined heat shrink tube for sealing around the splice.
  • 3:1 shrink ratio across the BHT series.
  • Copper crimp sleeve with model-specific diameter, length and wall thickness.
  • Four catalog sizes identified by wire range and insulation color.

Spécifications techniques

Parameter Catalog specification
Série BHT
Product type Heat shrinkable butt connector
Heat shrink tube material PE
Hot-melt adhesive Polyamide
Crimp sleeve material Copper (source Chinese text identifies 紫铜)
Shrink ratio 3:1
Température de fonctionnement −55 to +125 °C
Minimum shrink temperature 80 °C
Full recovery temperature 130 °C
Unaged tensile strength ≥16 MPa at room temperature
Unaged elongation ≥200% at room temperature
Aged tensile strength ≥11.5 MPa after 158 °C for 7 days
Aged elongation ≥100% after 158 °C for 7 days

The mechanical test values above are catalog test indicators; they are not product load ratings. The catalog also lists a 2.5 kV, one-minute withstand test, which should not be read as an operating voltage rating.

Dimension

Dimensions B, L2, W and L1 below are in millimeters. B and L2 describe the copper sleeve; W and L1 describe the heat shrink tube before installation.

Model Catalog AWG range Conductor range (mm²) B (mm) L2 (mm) W (mm) L1 (mm) Copper wall (mm) Color
BHT-0.5 20–22 0.3–0.5 1.0 12 3.0 26 0.5 Yellow
BHT-1.25 22–18 0.5–1.0 1.7 15 4.8 36.5 0.8 Red
BHT-2.5 16–14 1.5–2.5 2.4 15 5.8 36.5 0.8 Blue
BHT-5.5 12–10 4.0–6.0 3.6 15 6.8 41.5 1.0 Yellow

Selection Guide

Choose the model by the conductor cross-section and check its copper sleeve dimensions against the intended wire and crimp tooling. Specify the complete BHT model code and quantity when requesting a quote.

Dimension

BHT Heat Shrinkable Butt Connectors dimension drawing

Détails du projet

Les champs marqués d'un * sont obligatoires.

Vos coordonnées seront utilisées pour répondre à votre demande. Notice de confidentialité