{"id":2748,"date":"2026-10-07T10:22:50","date_gmt":"2026-10-07T10:22:50","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2748"},"modified":"2026-10-07T10:22:58","modified_gmt":"2026-10-07T10:22:58","slug":"ycc02-pole-branching-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/fr\/product\/ycc02-pole-branching-connectors\/","title":{"rendered":"YOCL Connecteurs de d\u00e9rivation unipolaires \u00e9lectriques YCC02"},"content":{"rendered":"<h2>Aper\u00e7u<\/h2>\n<p>Les connecteurs de d\u00e9rivation multipolaires YOCL ELECTRIC YCC02 offrent des configurations de connexion \u00e0 deux, trois, quatre ou six trous pour les c\u00e2bles en aluminium et en cuivre. Les mod\u00e8les standard et -E ont des sp\u00e9cifications de connexion suppl\u00e9mentaire diff\u00e9rentes. Les d\u00e9signations de mod\u00e8les grises, bleues et jaune\/vert sont r\u00e9pertori\u00e9es s\u00e9par\u00e9ment afin que le connecteur exact puisse \u00eatre s\u00e9lectionn\u00e9.<\/p>\n<h2>Caract\u00e9ristiques<\/h2>\n<ul>\n<li>Les sp\u00e9cifications des conducteurs en aluminium et en cuivre sont r\u00e9pertori\u00e9es s\u00e9par\u00e9ment.<\/li>\n<li>Formes \u00e0 deux, trois, quatre et six trous.<\/li>\n<li>Versions de connecteurs standard et -E.<\/li>\n<li>Couvercle en polyamide ; corps en aluminium \u00e9tam\u00e9 ou en laiton et vis en fer \u00e9tam\u00e9 ou en laiton.<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications techniques<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tension nominale<\/td>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<td>Courant nominal<\/td>\n<td>Al : 145 A ; Cu : 135 A<\/td>\n<\/tr>\n<tr>\n<td>Protection sans kit d'\u00e9tanch\u00e9it\u00e9<\/td>\n<td>IP23<\/td>\n<\/tr>\n<tr>\n<td>Protection avec kit d'\u00e9tanch\u00e9it\u00e9<\/td>\n<td>IP33<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature minimale d'installation<\/td>\n<td>+5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>\u221225 \u00e0 +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Mat\u00e9riau du couvercle<\/td>\n<td>Polyamide<\/td>\n<\/tr>\n<tr>\n<td>Corps<\/td>\n<td>Aluminium ou laiton, \u00e9tam\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Vis<\/td>\n<td>Fer ou laiton, \u00e9tam\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Sp\u00e9cifications du mod\u00e8le<\/h2>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Couleur<\/th>\n<th>Holes<\/th>\n<th>Al conductor specification (mm\u00b2)<\/th>\n<th>Cu conductor specification (mm\u00b2)<\/th>\n<th>Additional connection specification (mm\u00b2)<\/th>\n<th>Tension (V)<\/th>\n<th>Current Al\/Cu (A)<\/th>\n<th>Torque specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YCC02-2-GY<\/td>\n<td>Gris<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-BE<\/td>\n<td>Bleu<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-GY-E<\/td>\n<td>Gris<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-BE-E<\/td>\n<td>Bleu<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-GY<\/td>\n<td>Gris<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-BE<\/td>\n<td>Bleu<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-GY-E<\/td>\n<td>Gris<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-BE-E<\/td>\n<td>Bleu<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-GY<\/td>\n<td>Gris<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-BE<\/td>\n<td>Bleu<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-GY-E<\/td>\n<td>Gris<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-BE-E<\/td>\n<td>Bleu<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-GY<\/td>\n<td>Gris<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-BE<\/td>\n<td>Bleu<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>Non sp\u00e9cifi\u00e9<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-GY-E<\/td>\n<td>Gris<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-BE-E<\/td>\n<td>Bleu<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guide de s\u00e9lection<\/h2>\n<p>Choose hole arrangement, colour designation and standard or -E version together. The conductor entries are the specified cross-sections and quantities; they are not a substitute for an unstated conductor range. Apply the torque for the relevant screw size and conductor cross-section. IP33 applies with the sealing kit.<\/p>\n<h2>Informations de commande<\/h2>\n<p>Specify the exact model, quantity and conductor requirements when requesting a quotation. Select a complete model row; ratings and connection capacities are not interchangeable between models.<\/p>","protected":false},"excerpt":{"rendered":"<p>Connecteurs de d\u00e9rivation multipolaires YCC02 pour conducteurs Al\/Cu.<\/p>\n<ul>\n<li>Configurations \u00e0 deux, trois, quatre ou six trous.<\/li>\n<li>1000 V ; courant nominal Al 145 A \/ Cu 135 A.<\/li>\n<li>Mod\u00e8les standard et -E avec connexions suppl\u00e9mentaires distinctes.<\/li>\n<li>IP23 sans kit de scellement ; IP33 avec kit de scellement.<\/li>\n<li>D\u00e9signations de mod\u00e8les grises, bleues et jaune\/vert.<\/li>\n<\/ul>","protected":false},"featured_media":2743,"template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-2748","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-distribution-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product\/2748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media\/2743"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media?parent=2748"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2748"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2748"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}