{"id":2814,"date":"2026-10-07T12:44:29","date_gmt":"2026-10-07T12:44:29","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2814"},"modified":"2026-10-07T12:53:43","modified_gmt":"2026-10-07T12:53:43","slug":"sp13-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/fr\/product\/sp13-waterproof-circular-connectors\/","title":{"rendered":"Connecteurs circulaires \u00e9tanches SP13 IP68"},"content":{"rendered":"<h2>Aper\u00e7u<\/h2>\n<p>Les connecteurs circulaires \u00e9tanches YOCL ELECTRIC SP13 offrent un verrouillage filet\u00e9 et une terminaison \u00e0 souder pour les connexions de c\u00e2bles et de panneaux d\u00e9tachables. La famille utilise des contacts en cuivre plaqu\u00e9 or, des bo\u00eetiers thermoplastiques et des isolants en PPS, avec un indice de protection IP68.<\/p>\n<p>La s\u00e9rie couvre sept configurations de contacts : 2, 3, 4, 5, 6, 7 et 9 contacts. Les configurations \u00e0 2 et 3 contacts sont \u00e9valu\u00e9es \u00e0 13 A et 250 V AC ; les configurations avec plus de contacts ont leurs propres caract\u00e9ristiques indiqu\u00e9es ci-dessous. Deux tailles de passe-fils de c\u00e2ble accueillent des diam\u00e8tres de c\u00e2ble de 4\u20136.5 mm ou 5\u20138 mm.<\/p>\n<h2>Caract\u00e9ristiques<\/h2>\n<ul>\n<li><strong>Verrouillage filet\u00e9 :<\/strong> un accouplement \u00e0 vis maintient les moiti\u00e9s de connecteur d'accouplement.<\/li>\n<li><strong>Options de contact :<\/strong> contacts 2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9, avec des caract\u00e9ristiques \u00e9lectriques s\u00e9lectionn\u00e9es par la configuration des contacts.<\/li>\n<li><strong>Contacts en cuivre plaqu\u00e9 or :<\/strong> terminaison \u00e0 souder pour les configurations list\u00e9es sur cette page.<\/li>\n<li><strong>Formats de c\u00e2ble et de panneau :<\/strong> Fiche c\u00e2ble, embase c\u00e2ble en ligne, embase panneau \u00e9crou arri\u00e8re et embase \u00e0 bride.<\/li>\n<li><strong>S\u00e9lection du joint de c\u00e2ble :<\/strong> diam\u00e8tre de c\u00e2ble 4\u20136.5 mm ou 5\u20138 mm.<\/li>\n<li><strong>Plage de temp\u00e9rature :<\/strong> \u221240\u00b0C \u00e0 +85\u00b0C, avec 500 cycles d'accouplement list\u00e9s pour la s\u00e9rie.<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications techniques<\/h2>\n<h3>Sp\u00e9cifications courantes<\/h3>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marque<\/td>\n<td>YOCL \u00c9LECTRIQUE<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9rie<\/td>\n<td>SP13<\/td>\n<\/tr>\n<tr>\n<td>Configurations de contacts<\/td>\n<td>2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9 contacts<\/td>\n<\/tr>\n<tr>\n<td>Accouplement<\/td>\n<td>Verrouillage filet\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Terminaison<\/td>\n<td>Soudure<\/td>\n<\/tr>\n<tr>\n<td>Mat\u00e9riau du bo\u00eetier<\/td>\n<td>Thermoplastique PC \/ PA66<\/td>\n<\/tr>\n<tr>\n<td>Indice de inflammabilit\u00e9 du mat\u00e9riau du bo\u00eetier<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Mat\u00e9riau de l'isolant<\/td>\n<td>PPS thermoplastique<\/td>\n<\/tr>\n<tr>\n<td>Mat\u00e9riau du contact<\/td>\n<td>Cuivre plaqu\u00e9 or<\/td>\n<\/tr>\n<tr>\n<td>Indice de protection<\/td>\n<td>IP68<\/td>\n<\/tr>\n<tr>\n<td>Plage de temp\u00e9rature<\/td>\n<td>\u221240\u00b0C \u00e0 +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Cycles d'accouplement<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>R\u00e9sistance d'isolement<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Joint de c\u00e2ble type I<\/td>\n<td>4\u20136.5 mm ; le type I n'est pas indiqu\u00e9 dans la d\u00e9signation du mod\u00e8le<\/td>\n<\/tr>\n<tr>\n<td>Joint de c\u00e2ble type II<\/td>\n<td>5\u20138 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Caract\u00e9ristiques \u00e9lectriques par disposition des contacts<\/h3>\n<table>\n<thead>\n<tr>\n<th>Contacts<\/th>\n<th>Courant nominal<\/th>\n<th>Tension de service<\/th>\n<th>Diam\u00e8tre \u00d7 quantit\u00e9 de contacts<\/th>\n<th>Section transversale maximale du conducteur<\/th>\n<th>R\u00e9f\u00e9rence catalogue AWG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>13 A<\/td>\n<td>250 V AC<\/td>\n<td>\u00d81.6 mm \u00d7 2<\/td>\n<td>\u22642.0 mm\u00b2<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>13 A<\/td>\n<td>250 V AC<\/td>\n<td>\u00d81.6 mm \u00d7 3<\/td>\n<td>\u22642.0 mm\u00b2<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>5 A<\/td>\n<td>200 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 4<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>5 A<\/td>\n<td>180 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 5<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>5 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 6<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>5 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d81.0 mm \u00d7 7<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>3 A<\/td>\n<td>125 V AC<\/td>\n<td>\u00d80.7 mm \u00d7 9<\/td>\n<td>\u22640.5 mm\u00b2<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose the current, working voltage and conductor limit from the same row. The AWG values are the paired references supplied with the metric wire sizes; the conductor limit is expressed in mm\u00b2.<\/p>\n<h3>Dielectric Withstand and Contact Resistance<\/h3>\n<table>\n<thead>\n<tr>\n<th>Contacts<\/th>\n<th>Tension de tenue di\u00e9lectrique<\/th>\n<th>R\u00e9sistance de contact<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>1500 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>1000 V AC for 1 minute<\/td>\n<td>10 m\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The dielectric withstand value is a one-minute test voltage, separate from the working voltage.<\/p>\n<h2>Dimension<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp13-ip68-waterproof-circular-connectors-dimension.webp\" alt=\"SP13 IP68 Waterproof Circular Connectors dimension drawing\" \/><\/p>\n<h3>Dimensions du corps du connecteur<\/h3>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Famille de mod\u00e8les<\/th>\n<th>Drawing dimensions<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fiche de c\u00e2ble<\/td>\n<td>SP1310<\/td>\n<td>49.0 mm length; \u00d818.8 mm front diameter<\/td>\n<\/tr>\n<tr>\n<td>Douille de c\u00e2ble en ligne<\/td>\n<td>SP1311<\/td>\n<td>50.0 mm length; \u00d819.5 mm front diameter<\/td>\n<\/tr>\n<tr>\n<td>Douille de panneau arri\u00e8re-\u00e9crou<\/td>\n<td>SP1312<\/td>\n<td>19.2 mm length; \u00d819.5 mm front diameter; M13 \u00d7 1 mounting thread<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>SP1313<\/td>\n<td>18.5 mm length; 19.5 mm front height; \u00d83.5 mm mounting holes; 22.1 mm body mounting-hole pitch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Panel Mounting Dimensions<\/h3>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Panel opening<\/th>\n<th>D\u00e9tails de montage<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Douille de panneau arri\u00e8re-\u00e9crou<\/td>\n<td>\u00d813.0 mm opening with 12.1 mm across flats<\/td>\n<td>Maximum panel thickness: 3.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>\u00d813.0 mm centre opening<\/td>\n<td>Two \u00d83.5 mm holes at 22.0 mm pitch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Body dimensions and panel openings are listed separately. The flange body drawing gives 22.1 mm mounting-hole pitch, while the panel opening drawing gives 22.0 mm; use the panel opening dimensions when planning the panel.<\/p>\n<h2>Formats de connecteurs et d\u00e9signations de mod\u00e8les<\/h2>\n<table>\n<thead>\n<tr>\n<th>Format<\/th>\n<th>Pin-contact designation<\/th>\n<th>Socket-contact designation<\/th>\n<th>Matching format<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fiche de c\u00e2ble<\/td>\n<td>SP1310\/P<\/td>\n<td>SP1310\/S<\/td>\n<td>Mates with SP1311, SP1312 or SP1313 of the corresponding contact arrangement<\/td>\n<\/tr>\n<tr>\n<td>Douille de c\u00e2ble en ligne<\/td>\n<td>SP1311\/P<\/td>\n<td>SP1311\/S<\/td>\n<td>Cable-to-cable connection with SP1310<\/td>\n<\/tr>\n<tr>\n<td>Douille de panneau arri\u00e8re-\u00e9crou<\/td>\n<td>SP1312\/P<\/td>\n<td>SP1312\/S<\/td>\n<td>Panel connection with SP1310<\/td>\n<\/tr>\n<tr>\n<td>Flange socket<\/td>\n<td>SP1313\/P<\/td>\n<td>SP1313\/S<\/td>\n<td>Flange-mounted panel connection with SP1310<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>P<\/strong> identifies pin contacts and <strong>S<\/strong> identifies socket contacts. Both contact types are offered in each listed body format; choose complementary contacts and the same contact count for the mating pair. The designations above identify the connector format; specify the contact count separately in the enquiry.<\/p>\n<h2>Guide de s\u00e9lection<\/h2>\n<ol>\n<li>Select SP13 and the required contact count.<\/li>\n<li>Check the rated current, AC working voltage and conductor cross-section together in the electrical table.<\/li>\n<li>Choose a cable-to-cable or cable-to-panel connection and select the corresponding body format.<\/li>\n<li>Select Type I for 4\u20136.5 mm cable or Type II for 5\u20138 mm cable. Type I is unmarked in the catalogue designation; specify the seal size explicitly when ordering.<\/li>\n<li>Specify complementary P and S contacts and check the applicable body and panel dimensions.<\/li>\n<\/ol>\n<h2>Informations de commande<\/h2>\n<p>For a quotation, provide the SP13 model family, contact count, P or S contact type, cable outer diameter, mating connector format and required quantity. For panel sockets, include the panel thickness and mounting format.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Les connecteurs circulaires \u00e9tanches ELECTRIC SP13 combinent un verrouillage filet\u00e9 avec une terminaison \u00e0 souder pour les connexions de c\u00e2bles et de panneaux.<\/p>\n<ul>\n<li><strong>Contacts :<\/strong> 2 \/ 3 \/ 4 \/ 5 \/ 6 \/ 7 \/ 9.<\/li>\n<li><strong>Protection :<\/strong> IP68.<\/li>\n<li><strong>Diam\u00e8tre du c\u00e2ble :<\/strong> 4\u20136.5 mm ou 5\u20138 mm.<\/li>\n<li><strong>Formats :<\/strong> Fiche c\u00e2ble, embase c\u00e2ble en ligne, embase panneau \u00e9crou arri\u00e8re et embase \u00e0 bride.<\/li>\n<li><strong>Caract\u00e9ristiques :<\/strong> s\u00e9lectionnez le courant et la AC tension de fonctionnement par nombre de contacts dans le tableau des sp\u00e9cifications.<\/li>\n<\/ul>","protected":false},"featured_media":2812,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2814","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product\/2814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media\/2812"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media?parent=2814"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2814"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2814"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}