{"id":2891,"date":"2026-10-07T14:27:32","date_gmt":"2026-10-07T14:27:32","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2891"},"modified":"2026-10-07T14:27:41","modified_gmt":"2026-10-07T14:27:41","slug":"ip67-industrial-plugs","status":"publish","type":"product","link":"https:\/\/yocl.com\/fr\/product\/ip67-industrial-plugs\/","title":{"rendered":"IP67 Fiches industrielles"},"content":{"rendered":"<h2>Aper\u00e7u<\/h2>\n<p>Les fiches industrielles YOCL ELECTRIC IP67 sont des fiches m\u00e2les pour les connexions de c\u00e2bles industriels. Cette famille regroupe les mod\u00e8les 16 A, 32 A, 63 A et 125 A r\u00e9els list\u00e9s ci-dessous, avec des configurations de contacts 2P+E, 3P+E et 3P+N+E. Chaque mod\u00e8le a sa propre tension, sa position d'horloge de contact de terre et sa conception de bo\u00eetier.<\/p>\n<p>La face avant pr\u00e9sente des contacts m\u00e2les saillants et une conception d'accouplement \u00e0 bague de verrouillage, avec une entr\u00e9e de c\u00e2ble \u00e0 l'arri\u00e8re. Les conceptions de corps 16 \/ 32 A et 63 \/ 125 A sont s\u00e9par\u00e9es dans les tableaux de mod\u00e8les. Des versions sp\u00e9ciales 3h sont incluses en tant que mod\u00e8les nomm\u00e9s, avec leur propre position de contact.<\/p>\n<h2>Caract\u00e9ristiques<\/h2>\n<ul>\n<li>Indice de protection IP67 pour les mod\u00e8les list\u00e9s.<\/li>\n<li>Contacts m\u00e2les avec montage sur c\u00e2ble plut\u00f4t que montage sur panneau.<\/li>\n<li>Choix de courant nominal : 16 A, 32 A, 63 A et 125 A ; les combinaisons r\u00e9elles sont d\u00e9finies par les tableaux de mod\u00e8les.<\/li>\n<li>Les versions 2P+E, 3P+E et 3P+N+E sont identifi\u00e9es individuellement.<\/li>\n<li>Mises \u00e0 la terre : 4h, 6h et 3h s\u00e9lectionn\u00e9es, selon le mod\u00e8le nomm\u00e9.<\/li>\n<li>Les groupes de bo\u00eetiers s\u00e9par\u00e9s pr\u00e9servent la capacit\u00e9 de conducteur et les donn\u00e9es dimensionnelles de chaque mod\u00e8le.<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications techniques<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marque<\/td>\n<td>YOCL \u00c9LECTRIQUE<\/td>\n<\/tr>\n<tr>\n<td>Type de produit<\/td>\n<td>Fiches m\u00e2les<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Montage sur c\u00e2ble<\/td>\n<\/tr>\n<tr>\n<td>Indice de protection<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Courants nominaux<\/td>\n<td>16 A, 32 A, 63 A et 125 A<\/td>\n<\/tr>\n<tr>\n<td>Configurations de contacts<\/td>\n<td>2P+E (3 contacts) ; 3P+E (4 contacts) ; 3P+N+E (5 contacts)<\/td>\n<\/tr>\n<tr>\n<td>Positions de mise \u00e0 la terre<\/td>\n<td>4h, 6h et 3h s\u00e9lectionn\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Configurations de tension<\/td>\n<td>Voir les lignes de mod\u00e8les individuelles ; les valeurs nominales appari\u00e9es \u00e0 cinq contacts sont conserv\u00e9es telles qu'indiqu\u00e9es.<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9s des conducteurs<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conception du bo\u00eetier \u00e0 bague de verrouillage \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Printed reference<\/th>\n<th>Courant (A)<\/th>\n<th>Contacts<\/th>\n<th>Tension (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0131-4<\/td>\n<td>278<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Jaune<\/td>\n<\/tr>\n<tr>\n<td>NM-0231-4<\/td>\n<td>290<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Jaune<\/td>\n<\/tr>\n<tr>\n<td>NM-0131<\/td>\n<td>278<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0231<\/td>\n<td>290<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0141<\/td>\n<td>282<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0241<\/td>\n<td>294<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0151<\/td>\n<td>288<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0251<\/td>\n<td>291<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conception de verrouillage du corps arri\u00e8re blanc \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Courant (A)<\/th>\n<th>Contacts<\/th>\n<th>Tension (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>1\u20132.5<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>2.5\u20136<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conception du corps arri\u00e8re gris \u2014 63 \/ 125 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Courant (A)<\/th>\n<th>Contacts<\/th>\n<th>Tension (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-0342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conception du corps arri\u00e8re blanc \u2014 63 \/ 125 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Courant (A)<\/th>\n<th>Contacts<\/th>\n<th>Tension (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-033<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-043<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Bleu<\/td>\n<\/tr>\n<tr>\n<td>NM-034<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-044<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-035<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>6\u201316<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-045<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>h 6<\/td>\n<td>16\u201350<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Disposition sp\u00e9ciale des contacts 3h \u2014 16 \/ 32 A<\/h2>\n<p>These 3h models are distinct from the ordinary 6h models; the model suffix must be included when ordering.<\/p>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Courant (A)<\/th>\n<th>Contacts<\/th>\n<th>Tension (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u2014<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<tr>\n<td>NM-0242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>\u2014<\/td>\n<td>Rouge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Conception du bo\u00eetier \u00e0 bague de verrouillage \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0131-4<\/td>\n<td>a = 138; b = 115; d = 70.2<\/td>\n<\/tr>\n<tr>\n<td>NM-0231-4<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0131<\/td>\n<td>a = 138; b = 115; d = 70.2<\/td>\n<\/tr>\n<tr>\n<td>NM-0231<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0141<\/td>\n<td>a = 144; b = 120.5; d = 78<\/td>\n<\/tr>\n<tr>\n<td>NM-0241<\/td>\n<td>a = 170; b = 141; d = 93.3<\/td>\n<\/tr>\n<tr>\n<td>NM-0151<\/td>\n<td>a = 144; b = 120.5; d = 87<\/td>\n<\/tr>\n<tr>\n<td>NM-0251<\/td>\n<td>a = 177; b = 148; d = 101<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Conception de verrouillage du corps arri\u00e8re blanc \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0132<\/td>\n<td>a = 127; b = 47; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0232<\/td>\n<td>a = 158; b = 63; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-0142<\/td>\n<td>a = 133; b = 53; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0242<\/td>\n<td>a = 158; b = 63; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<tr>\n<td>NM-0152<\/td>\n<td>a = 140; b = 61; c = 6\u201315; SW = 44<\/td>\n<\/tr>\n<tr>\n<td>NM-0252<\/td>\n<td>a = 165; b = 69; c = 10\u201320; SW = 54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Conception du corps arri\u00e8re gris \u2014 63 \/ 125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-0332<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0432<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<tr>\n<td>NM-0342<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0442<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<tr>\n<td>NM-0352<\/td>\n<td>a = 250; b = 115; c = 23<\/td>\n<\/tr>\n<tr>\n<td>NM-0452<\/td>\n<td>a = 275; b = 128; c = 31<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Conception du corps arri\u00e8re blanc \u2014 63 \/ 125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-033<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-043<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<tr>\n<td>NM-034<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-044<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<tr>\n<td>NM-035<\/td>\n<td>a = 231.5; b = 110; c = 16\u201338; \u03c6 = 110<\/td>\n<\/tr>\n<tr>\n<td>NM-045<\/td>\n<td>a = 295; b = 123; c = 30\u201364; \u03c6 = 123<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-02.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-03.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-04.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-industrial-plugs-dimension-05.webp\" alt=\"IP67 Industrial Plugs dimension drawing\"><\/p>\n<h2>Guide de s\u00e9lection<\/h2>\n<p>Choose a male cable plug for a cable-end connection. A panel-mounted or surface-mounted appliance inlet uses a fixed mounting arrangement and belongs to a different product family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Informations de commande<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP67 industrial plugs, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL \u00c9LECTRIQUE IP67 fiches industrielles pour connexions de bout de c\u00e2ble, avec des conceptions de bo\u00eetier distinctes et des tables compl\u00e8tes de s\u00e9lection de mod\u00e8les NM.<\/p>\n<ul>\n<li>Courants nominaux : 16 A, 32 A, 63 A et 125 A.<\/li>\n<li>Agencements de contacts : 2P+E, 3P+E et 3P+N+E.<\/li>\n<li>4h, 6h et 3h s\u00e9lectionn\u00e9es avec contact de terre, selon le mod\u00e8le.<\/li>\n<li>Fiche m\u00e2le avec entr\u00e9e de c\u00e2ble arri\u00e8re.<\/li>\n<li>S\u00e9lectionnez la tension, la capacit\u00e9 du conducteur et les dimensions par le code mod\u00e8le complet.<\/li>\n<\/ul>","protected":false},"featured_media":2885,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2891","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product\/2891","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media\/2885"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media?parent=2891"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2891"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2891"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2891"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}