{"id":672,"date":"2026-09-29T11:13:25","date_gmt":"2026-09-29T11:13:25","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=672"},"modified":"2026-10-02T14:00:24","modified_gmt":"2026-10-02T14:00:24","slug":"rvd-double-crimp-ring-terminal","status":"publish","type":"product","link":"https:\/\/yocl.com\/fr\/product\/rvd-double-crimp-ring-terminal\/","title":{"rendered":"RVD Double-Crimp Ring Terminal"},"content":{"rendered":"<h2>Overview<\/h2>\n<p>YOCL ELECTRIC RVD Double-Crimp Ring Terminal is a copper ring terminal with a PVC insulating sleeve and an additional copper tube for the double-crimp construction shown in the reference. The ring eyelet connects to a suitably sized bolt or stud, and the barrel receives the conductor. The two catalog pages list 47 RVD models in red, blue and yellow conductor groups, covering 0.5\u20136 mm\u00b2.<\/p>\n<h2>Features<\/h2>\n<ul>\n<li><strong>Double-crimp structure:<\/strong> the source identifies an insulating sleeve plus copper tube for the double-pressure design.<\/li>\n<li><strong>Copper terminal:<\/strong> the catalog identifies the conductive terminal material as copper.<\/li>\n<li><strong>Colour-coded groups:<\/strong> group colour identifies the listed conductor range.<\/li>\n<li><strong>Model-specific bolt fit:<\/strong> each model lists both a US bolt number and metric hole diameter d2.<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Series<\/td>\n<td>RVD<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Double-crimp ring terminal<\/td>\n<\/tr>\n<tr>\n<td>Terminal material<\/td>\n<td>Copper<\/td>\n<\/tr>\n<tr>\n<td>PVC insulating sleeve<\/td>\n<td>Specified for all three listed groups<\/td>\n<\/tr>\n<tr>\n<td>Listed models<\/td>\n<td>47<\/td>\n<\/tr>\n<tr>\n<td>Conductor ranges across listed groups<\/td>\n<td>0.5\u20136 mm\u00b2; see group table for the available intervals<\/td>\n<\/tr>\n<tr>\n<td>Drawing dimension units<\/td>\n<td>mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The maximum current and terminal material thickness are stated by colour group, not as one rating for every model. Imax is the source&#8217;s maximum-current label.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model group \/ colour<\/th>\n<th>Conductor range<\/th>\n<th>AWG<\/th>\n<th>Imax<\/th>\n<th>Material thickness<\/th>\n<th>E (mm)<\/th>\n<th>D1 (mm)<\/th>\n<th>D2 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RVD 1.25 \/ Red<\/td>\n<td>0.5\u20131.5 mm\u00b2<\/td>\n<td>AWG 22\u201316<\/td>\n<td>19 A<\/td>\n<td>0.7 mm<\/td>\n<td>10.0<\/td>\n<td>4.3<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 2 \/ Blue<\/td>\n<td>1.5\u20132.5 mm\u00b2<\/td>\n<td>AWG 16\u201314<\/td>\n<td>27 A<\/td>\n<td>0.8 mm<\/td>\n<td>10.0<\/td>\n<td>4.9<\/td>\n<td>5.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5 \/ Yellow<\/td>\n<td>4\u20136 mm\u00b2<\/td>\n<td>AWG 12\u201310<\/td>\n<td>48 A<\/td>\n<td>1.0 mm<\/td>\n<td>13.0<\/td>\n<td>6.7<\/td>\n<td>7.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimension<\/h2>\n<p>The table and drawing use B, F, L, E, D1 and D2 as dimension labels. The table&#8217;s d2 is the metric bolt-hole diameter. All B, F, L, E, D1, D2 and d2 values are in millimeters; the US bolt number is a separate size designation.<\/p>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Colour<\/th>\n<th>US bolt no.<\/th>\n<th>Hole d2 (mm)<\/th>\n<th>B (mm)<\/th>\n<th>F (mm)<\/th>\n<th>L (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>RVD 1.25-3<\/td>\n<td>Red<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>5.7<\/td>\n<td>4.95<\/td>\n<td>17.8<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-3.5S<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>5.7<\/td>\n<td>4.95<\/td>\n<td>17.8<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-3.5M<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.6<\/td>\n<td>6.3<\/td>\n<td>19.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-3.5L<\/td>\n<td>Red<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-4S<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.6<\/td>\n<td>6.3<\/td>\n<td>19.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-4L<\/td>\n<td>Red<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-5S<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.0<\/td>\n<td>7.0<\/td>\n<td>21.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-5L<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>8.5<\/td>\n<td>22.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-5LL<\/td>\n<td>Red<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>11.6<\/td>\n<td>11.1<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-6S<\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>8.5<\/td>\n<td>22.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-6L<\/td>\n<td>Red<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>11.6<\/td>\n<td>11.1<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-8<\/td>\n<td>Red<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>11.6<\/td>\n<td>11.1<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-10<\/td>\n<td>Red<\/td>\n<td>3\/8<\/td>\n<td>10.5<\/td>\n<td>13.6<\/td>\n<td>13.9<\/td>\n<td>30.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-10L<\/td>\n<td>Red<\/td>\n<td>3\/8<\/td>\n<td>10.5<\/td>\n<td>19.2<\/td>\n<td>16.0<\/td>\n<td>35.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-12<\/td>\n<td>Red<\/td>\n<td>1\/2<\/td>\n<td>13.0<\/td>\n<td>19.2<\/td>\n<td>16.0<\/td>\n<td>35.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-14<\/td>\n<td>Red<\/td>\n<td>9\/16<\/td>\n<td>15.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-16<\/td>\n<td>Red<\/td>\n<td>5\/8<\/td>\n<td>17.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 1.25-20<\/td>\n<td>Red<\/td>\n<td>3\/4<\/td>\n<td>21.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-3<\/td>\n<td>Blue<\/td>\n<td>#4<\/td>\n<td>3.2<\/td>\n<td>6.6<\/td>\n<td>4.3<\/td>\n<td>17.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-3.5S<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.6<\/td>\n<td>4.3<\/td>\n<td>17.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-3.5M<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>6.6<\/td>\n<td>6.3<\/td>\n<td>19.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-3.5L<\/td>\n<td>Blue<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>21.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-4S<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>6.6<\/td>\n<td>6.3<\/td>\n<td>19.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-4L<\/td>\n<td>Blue<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>21.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-5S<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>8.5<\/td>\n<td>7.4<\/td>\n<td>21.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-5L<\/td>\n<td>Blue<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>7.4<\/td>\n<td>22.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-6S<\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>9.5<\/td>\n<td>7.4<\/td>\n<td>22.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-6L<\/td>\n<td>Blue<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-8<\/td>\n<td>Blue<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>12.0<\/td>\n<td>11.0<\/td>\n<td>27.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-10<\/td>\n<td>Blue<\/td>\n<td>3\/8<\/td>\n<td>10.5<\/td>\n<td>13.6<\/td>\n<td>13.9<\/td>\n<td>30.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-10L<\/td>\n<td>Blue<\/td>\n<td>3\/8<\/td>\n<td>10.5<\/td>\n<td>19.2<\/td>\n<td>16.0<\/td>\n<td>35.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-12<\/td>\n<td>Blue<\/td>\n<td>1\/2<\/td>\n<td>13.0<\/td>\n<td>19.2<\/td>\n<td>16.0<\/td>\n<td>35.6<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-14<\/td>\n<td>Blue<\/td>\n<td>9\/16<\/td>\n<td>15.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-16<\/td>\n<td>Blue<\/td>\n<td>5\/8<\/td>\n<td>17.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 2-20<\/td>\n<td>Blue<\/td>\n<td>3\/4<\/td>\n<td>21.0<\/td>\n<td>27.0<\/td>\n<td>21.0<\/td>\n<td>44.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-3.5<\/td>\n<td>Yellow<\/td>\n<td>#6<\/td>\n<td>3.7<\/td>\n<td>7.2<\/td>\n<td>6.1<\/td>\n<td>22.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-4S<\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>6.1<\/td>\n<td>22.7<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-4L<\/td>\n<td>Yellow<\/td>\n<td>#8<\/td>\n<td>4.3<\/td>\n<td>9.5<\/td>\n<td>8.3<\/td>\n<td>26.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-5<\/td>\n<td>Yellow<\/td>\n<td>#10<\/td>\n<td>5.3<\/td>\n<td>9.5<\/td>\n<td>8.3<\/td>\n<td>26.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-6<\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>10.5<\/td>\n<td>29.5<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-6M<\/td>\n<td>Yellow<\/td>\n<td>1\/4<\/td>\n<td>6.5<\/td>\n<td>12.0<\/td>\n<td>13.0<\/td>\n<td>32.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-8<\/td>\n<td>Yellow<\/td>\n<td>5\/16<\/td>\n<td>8.5<\/td>\n<td>15.0<\/td>\n<td>13.7<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-10<\/td>\n<td>Yellow<\/td>\n<td>3\/8<\/td>\n<td>10.5<\/td>\n<td>15.0<\/td>\n<td>13.7<\/td>\n<td>35.0<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-12<\/td>\n<td>Yellow<\/td>\n<td>1\/2<\/td>\n<td>13.0<\/td>\n<td>19.2<\/td>\n<td>16.0<\/td>\n<td>39.4<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-14<\/td>\n<td>Yellow<\/td>\n<td>9\/16<\/td>\n<td>15.0<\/td>\n<td>32.0<\/td>\n<td>25.2<\/td>\n<td>54.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-16<\/td>\n<td>Yellow<\/td>\n<td>5\/8<\/td>\n<td>17.0<\/td>\n<td>32.0<\/td>\n<td>25.2<\/td>\n<td>54.2<\/td>\n<\/tr>\n<tr>\n<td>RVD 5.5-20<\/td>\n<td>Yellow<\/td>\n<td>3\/4<\/td>\n<td>21.0<\/td>\n<td>32.0<\/td>\n<td>25.2<\/td>\n<td>54.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The E, D1 and D2 dimensions are shown by colour group in the specification table above. The RVD column lists 1.25, 2 and 5.5 groups only; no RVD entries are shown for the other groups on these pages.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/09\/rvd-double-crimp-ring-terminal-dimension.webp\" alt=\"RVD Double-Crimp Ring Terminal dimension drawing\" \/><\/p>\n<h2>Selection Guide<\/h2>\n<p>Choose the conductor group first, then check the required bolt or stud size against the listed US bolt designation and actual d2 hole diameter. Compare B, F, L and the group-level sleeve dimensions with the available connection space. Use the model&#8217;s colour-group Imax value only in the context of the catalog specification; the source gives no operating conditions for that maximum.<\/p>\n<h2>Applications<\/h2>\n<p>Bolted conductor connections to compatible electrical equipment terminals.<\/p>\n<h2>Ordering Information<\/h2>\n<p>Specify the exact RVD model and quantity when requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC RVD Double-Crimp Ring Terminal is a copper terminal for bolted conductor connections. The 47 listed models cover 0.5\u20136 mm\u00b2 conductor groups in red, blue and yellow.<\/p>\n<ul>\n<li>Select by conductor range and bolt-hole diameter.<\/li>\n<li>Model-specific US bolt number, d2, B, F and L values are listed in the detail table.<\/li>\n<li>Group-specific maximum current, material thickness, E, D1 and D2 values are shown separately.<\/li>\n<\/ul>","protected":false},"featured_media":1805,"template":"","meta":[],"product_brand":[],"product_cat":[158],"product_tag":[],"class_list":["post-672","product","type-product","status-publish","has-post-thumbnail","product_cat-pvc-insulated-terminals","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product\/672","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media\/1805"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/media?parent=672"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_brand?post=672"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_cat?post=672"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/fr\/wp-json\/wp\/v2\/product_tag?post=672"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}