YOCL

Nylon Waterproof Breathable Cable Gland

Nylon cable gland combining cable entry sealing with a breathable design.

  • Specified ingress protection: IP68.
  • 4 configurations with model-specific cable ranges and metric threads.
  • Minimum airflow requirements: 100 mL/min across the listed configurations, measured at 70 mbar.
  • Black and white body options.
  • Nylon PA clamping insert; NBR and EPDM sealing materials listed.
  • Ambient temperature −40 °C to +100 °C; short-term exposure up to +120 °C.
Tanyakan tentang produk ini

Tinjauan

The YOCL ELECTRIC Nylon Waterproof Breathable Cable Gland combines cable entry sealing with a breathable design. The supplied size table specifies cable diameter ranges, minimum airflow at a pressure differential of 70 mbar, metric entry threads and installation dimensions.

The body is nylon. Select the configuration using its cable range, airflow requirement, thread length and wrench size.

Fitur

  • Breathable cable entry: Model-specific minimum airflow values stated at 70 mbar.
  • IP68 protection: As specified in the supplied product data.
  • Material selection: Nylon body.
  • Metric thread configurations: Cable clamping ranges and dimensions listed separately below.
  • Colour options: Black and white.

Spesifikasi Teknis

Parameter Spesifikasi
Jenis produk Waterproof breathable cable gland
Body material Nylon
Colour / finish Black; White
Ingress protection IP68
Airflow test pressure differential 70 mbar
Airflow specification Minimum airflow varies by configuration; see table below
Entry thread Metric, 1.5 mm pitch
Clamping insert Nylon PA
Listed sealing materials Nitrile rubber (NBR); EPDM
Ambient temperature −40 °C to +100 °C
Short-term temperature Up to +120 °C

IP68 immersion depth and duration are not provided in the supplied data.
The source lists NBR and EPDM without assigning them to individual configurations. The allowed duration of short-term +120 °C exposure is not stated.

Dimensi

Cable Range and Airflow

All cable dimensions are in millimetres. Airflow is the minimum value at 70 mbar.

Configuration Entry thread Cable range (mm) Minimum airflow (mL/min at 70 mbar)
M12×1.5/4–8 M12×1.5 4–8 ≥100
M16×1.5/4–8 M16×1.5 4–8 ≥100
M16×1.5/5–10 M16×1.5 5–10 ≥100
M20×1.5/5–10 M20×1.5 5–10 ≥100

Installation Dimensions

AG is the nominal metric thread diameter; GL is the entry thread length. Wrench sizes are in millimetres.

Configuration Minimum airflow (mL/min at 70 mbar) Thread diameter AG (mm) Thread length GL (mm) Wrench size (mm)
M12×1.5/4–8 ≥100 12 9 19
M16×1.5/4–8 ≥100 16 9 22
M16×1.5/5–10 ≥100 16 9 22
M20×1.5/5–10 ≥100 20 9 24

Overall body height H is shown in the reference drawing but is not tabulated; no H values are assigned here.

Informasi Pemesanan

Specify the body material, metric thread size, cable diameter range and required minimum airflow. Check the entry thread length and available wrench clearance against the enclosure.
Include the required colour, black or white.
Include the required sealing material and temperature conditions in the order.

Detail proyek

Bidang yang ditandai * wajib diisi.

Detail Anda akan digunakan untuk menanggapi pertanyaan Anda. Pemberitahuan privasi