{"id":2844,"date":"2026-10-07T13:14:30","date_gmt":"2026-10-07T13:14:30","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2844"},"modified":"2026-10-07T13:14:38","modified_gmt":"2026-10-07T13:14:38","slug":"ip44-angled-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/id\/product\/ip44-angled-panel-sockets\/","title":{"rendered":"IP44 Soket Dudukan Panel Miring"},"content":{"rendered":"<h2>Tinjauan<\/h2>\n<p>YOCL ELECTRIC IP44 soket industri bersudut yang dipasang di panel menyediakan titik koneksi betina tetap untuk colokan industri yang kompatibel. Seri ini mencakup peringkat 16 \/ 32 A dan susunan kontak 2P+E, 3P+E, 3P+N+E. Setiap model menggabungkan peringkat arus tertentu, tegangan, posisi kontak bumi, dan desain housing.<\/p>\n<p>Tabel pemilihan menyatukan versi selungkup yang tersedia dalam satu keluarga produk. Gunakan kode model NM lengkap untuk menentukan konfigurasi listrik dan dimensi pemasangan yang sesuai.<\/p>\n<h2>Fitur<\/h2>\n<ul>\n<li>Badan soket bersudut dan flensa pemasangan untuk instalasi panel.<\/li>\n<li>Peringkat perlindungan IP44 untuk model yang tercantum.<\/li>\n<li>Penutup berengsel di muka soket.<\/li>\n<li>Konfigurasi biru dan merah terdaftar berdasarkan model yang tepat dalam tabel pemilihan.<\/li>\n<li>Rentang konduktor dan dimensi pemasangan spesifik model untuk memilih koneksi listrik dan ruang instalasi.<\/li>\n<\/ul>\n<h2>Spesifikasi Teknis<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spesifikasi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Merek<\/td>\n<td>YOCL ELEKTRIK<\/td>\n<\/tr>\n<tr>\n<td>Jenis produk<\/td>\n<td>IP44 Soket Dudukan Panel Miring<\/td>\n<\/tr>\n<tr>\n<td>Jenis Kelamin Kontak<\/td>\n<td>Soket betina<\/td>\n<\/tr>\n<tr>\n<td>Pemasangan<\/td>\n<td>Dipasang pada panel bersudut<\/td>\n<\/tr>\n<tr>\n<td>Rating proteksi<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Pilihan arus terukur<\/td>\n<td>16 \/ 32 A<\/td>\n<\/tr>\n<tr>\n<td>Susunan kontak<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Konfigurasi tegangan<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posisi kontak pentanahan<\/td>\n<td>6 jam<\/td>\n<\/tr>\n<tr>\n<td>Penampang konduktor<\/td>\n<td>Nilai spesifik model dalam tabel pemilihan<\/td>\n<\/tr>\n<tr>\n<td>Versi housing<\/td>\n<td>H housing, 16\/32 A; Standard housing, 16\/32 A<\/td>\n<\/tr>\n<tr>\n<td>Opsi model<\/td>\n<td>12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabel Pemilihan Model<\/h2>\n<p>Nilai tegangan dan arus termasuk dalam baris model yang tepat. Tanda hubung menunjukkan bahwa tidak ada nilai spesifik model yang tersedia dalam data yang diberikan.<\/p>\n<h3>Rumah H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413H<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-423H<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-414H<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-424H<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-415H<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-425H<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-423<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-414<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-424<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-415<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-425<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensi<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Rumah H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413H<\/td>\n<td>64<\/td>\n<td>75<\/td>\n<td>52<\/td>\n<td>60<\/td>\n<td>50<\/td>\n<td>60<\/td>\n<\/tr>\n<tr>\n<td>NM-423H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-414H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-424H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-415H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-425H<\/td>\n<td>93<\/td>\n<td>101<\/td>\n<td>77<\/td>\n<td>85<\/td>\n<td>73<\/td>\n<td>86<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing holes \u00d85.<\/p>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>t (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-413<\/td>\n<td>62<\/td>\n<td>68<\/td>\n<td>47<\/td>\n<td>48<\/td>\n<td>36<\/td>\n<td>37<\/td>\n<td>55<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>NM-423<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>43<\/td>\n<td>75<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<td>NM-414<\/td>\n<td>76<\/td>\n<td>86<\/td>\n<td>62<\/td>\n<td>62<\/td>\n<td>47<\/td>\n<td>37<\/td>\n<td>64<\/td>\n<td>57<\/td>\n<\/tr>\n<tr>\n<td>NM-424<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>43<\/td>\n<td>75<\/td>\n<td>66<\/td>\n<\/tr>\n<tr>\n<td>NM-415<\/td>\n<td>76<\/td>\n<td>86<\/td>\n<td>62<\/td>\n<td>62<\/td>\n<td>47<\/td>\n<td>37<\/td>\n<td>72<\/td>\n<td>65<\/td>\n<\/tr>\n<tr>\n<td>NM-425<\/td>\n<td>80<\/td>\n<td>96<\/td>\n<td>62<\/td>\n<td>73<\/td>\n<td>42<\/td>\n<td>47<\/td>\n<td>81<\/td>\n<td>70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing holes \u00d85.<\/p>\n<h2>Panduan Pemilihan<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informasi Pemesanan<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 soket industri bersudut yang dipasang di panel untuk koneksi daya industri tetap.<\/p>\n<ul>\n<li>Peringkat arus: 16 \/ 32 A.<\/li>\n<li>Susunan kontak: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Soket betina dengan penutup berengsel dan flensa pemasangan panel.<\/li>\n<li>Tabel pemilihan model lengkap mencakup tegangan, posisi kontak bumi, rentang konduktor, dan dimensi spesifik housing.<\/li>\n<li>Pilih dan tanyakan berdasarkan kode model NM lengkap.<\/li>\n<\/ul>","protected":false},"featured_media":2843,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2844","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product\/2844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media\/2843"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media?parent=2844"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_brand?post=2844"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_cat?post=2844"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_tag?post=2844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}