{"id":2846,"date":"2026-10-07T13:33:13","date_gmt":"2026-10-07T13:33:13","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2846"},"modified":"2026-10-07T13:35:45","modified_gmt":"2026-10-07T13:35:45","slug":"ip44-industrial-appliance-inlets","status":"publish","type":"product","link":"https:\/\/yocl.com\/id\/product\/ip44-industrial-appliance-inlets\/","title":{"rendered":"IP44 Saluran Masuk Peralatan Industri"},"content":{"rendered":"<h2>Tinjauan<\/h2>\n<p>YOCL ELECTRIC IP44 inlet alat industri menyediakan koneksi daya pria pada mesin, peralatan distribusi, dan rumah peralatan. Keluarga ini mencakup versi 16 A dan 32 A dalam konfigurasi 2P+E, 3P+E, dan 3P+N+E. Inlet panel lurus dan desain inlet permukaan tertutup dikelompokkan di sini sehingga antarmuka suplai dapat dipilih bersama dengan pengaturan pemasangannya. Konektor kabel wanita yang cocok menyediakan koneksi kabel yang dapat dilepas.<\/p>\n<h2>Fitur<\/h2>\n<ul>\n<li>Versi IP44 untuk koneksi industri tahan percikan.<\/li>\n<li>Desain panel lurus dalam housing standar dan K, ditambah desain permukaan dengan muka konektor bersudut.<\/li>\n<li>Pilihan 16 A dan 32 A dengan rentang konduktor yang dinyatakan untuk setiap model.<\/li>\n<li>Posisi kontak bumi 6h pada model yang terdaftar.<\/li>\n<li>Housing kontak biru dan merah membedakan konfigurasi listrik yang terdaftar.<\/li>\n<\/ul>\n<h2>Spesifikasi Teknis<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spesifikasi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Merek<\/td>\n<td>YOCL ELEKTRIK<\/td>\n<\/tr>\n<tr>\n<td>Jenis produk<\/td>\n<td>Inlet industri \/ inlet peralatan pria<\/td>\n<\/tr>\n<tr>\n<td>Tingkat proteksi<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Pilihan arus terukur<\/td>\n<td>16 A, 32 A<\/td>\n<\/tr>\n<tr>\n<td>Konfigurasi kontak<\/td>\n<td>2P+E; 3P+E; 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Posisi kontak-bumi<\/td>\n<td>6 jam<\/td>\n<\/tr>\n<tr>\n<td>Pemasangan<\/td>\n<td>Pemasangan panel atau pemasangan permukaan tertutup, tergantung model<\/td>\n<\/tr>\n<tr>\n<td>Antarmuka kabel pasangan<\/td>\n<td>Konektor kabel industri wanita pasangan<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas konduktor<\/td>\n<td>Spesifik model; lihat tabel pemilihan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Pemilihan Model<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Pemasangan \/ rumah<\/th>\n<th>Arus (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan<\/th>\n<th>Posisi bumi<\/th>\n<th>Rumah kontak<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>P denotes a phase contact, N neutral and E protective earth. A dash means that no voltage is assigned in this selection table.<\/p>\n<h2>Dimensi<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Lettered outline dimensions (mm)<\/th>\n<th>Fixed mounting geometry<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use the lettered dimensions with the matching inlet outline. Flange geometry and housing size differ between body versions; select the complete model code when checking installation space.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-02.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-03.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<h2>Pemilihan Koneksi<\/h2>\n<p>Match rated current, contact configuration, voltage and earth-contact position at both sides of the connection. Select panel or surface mounting before comparing the housing dimensions. The IP rating applies to the correctly assembled connection with its compatible mating interface; maintain the specified sealing and closure arrangement.<\/p>\n<h2>Informasi Pemesanan<\/h2>\n<p>Send YOCL ELECTRIC the full model code, required quantity, supply voltage, contact configuration and installation arrangement. Include conductor cross-section and the mating cable connector when requesting a complete equipment power connection.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 inlet alat industri dalam versi 16 A dan 32 A. Pilih kontak 2P+E, 3P+E atau 3P+N+E, pemasangan panel atau permukaan dan kapasitas konduktor yang sesuai dari tabel model.<\/p>","protected":false},"featured_media":2845,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2846","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media\/2845"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_brand?post=2846"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_cat?post=2846"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_tag?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}