{"id":2867,"date":"2026-10-07T14:08:28","date_gmt":"2026-10-07T14:08:28","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2867"},"modified":"2026-10-07T14:08:37","modified_gmt":"2026-10-07T14:08:37","slug":"ip44-straight-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/id\/product\/ip44-straight-panel-sockets\/","title":{"rendered":"IP44 Soket Dudukan Panel Lurus"},"content":{"rendered":"<h2>Tinjauan<\/h2>\n<p>YOCL ELECTRIC IP44 soket industri lurus yang dipasang di panel menyediakan titik koneksi betina tetap untuk colokan industri yang kompatibel. Seri ini mencakup peringkat 16 \/ 32 A dan susunan kontak 2P+E, 3P+E, 3P+N+E. Setiap model menggabungkan peringkat arus, tegangan, posisi kontak bumi, dan desain housing tertentu.<\/p>\n<p>Tabel pemilihan menyatukan versi selungkup yang tersedia dalam satu keluarga produk. Gunakan kode model NM lengkap untuk menentukan konfigurasi listrik dan dimensi pemasangan yang sesuai.<\/p>\n<h2>Fitur<\/h2>\n<ul>\n<li>Sumbu soket lurus dan flensa pemasangan untuk instalasi panel.<\/li>\n<li>Peringkat perlindungan IP44 untuk model yang tercantum.<\/li>\n<li>Penutup berengsel di muka soket.<\/li>\n<li>Konfigurasi biru dan merah terdaftar berdasarkan model yang tepat dalam tabel pemilihan.<\/li>\n<li>Rentang konduktor dan dimensi pemasangan spesifik model untuk memilih koneksi listrik dan ruang instalasi.<\/li>\n<\/ul>\n<h2>Spesifikasi Teknis<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spesifikasi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Merek<\/td>\n<td>YOCL ELEKTRIK<\/td>\n<\/tr>\n<tr>\n<td>Jenis produk<\/td>\n<td>IP44 Soket Dudukan Panel Lurus<\/td>\n<\/tr>\n<tr>\n<td>Jenis Kelamin Kontak<\/td>\n<td>Soket betina<\/td>\n<\/tr>\n<tr>\n<td>Pemasangan<\/td>\n<td>Terpasang di panel lurus<\/td>\n<\/tr>\n<tr>\n<td>Rating proteksi<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Pilihan arus terukur<\/td>\n<td>16 \/ 32 A<\/td>\n<\/tr>\n<tr>\n<td>Susunan kontak<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Konfigurasi tegangan<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posisi kontak pentanahan<\/td>\n<td>6 jam<\/td>\n<\/tr>\n<tr>\n<td>Penampang konduktor<\/td>\n<td>Nilai spesifik model dalam tabel pemilihan<\/td>\n<\/tr>\n<tr>\n<td>Versi housing<\/td>\n<td>Rumah H, 16\/32 A; Rumah K, 16\/32 A; Rumah standar, 16\/32 A<\/td>\n<\/tr>\n<tr>\n<td>Opsi model<\/td>\n<td>18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabel Pemilihan Model<\/h2>\n<p>Nilai tegangan dan arus termasuk dalam baris model yang tepat. Tanda hubung menunjukkan bahwa tidak ada nilai spesifik model yang tersedia dalam data yang diberikan.<\/p>\n<h3>Rumah H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313H<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-323H<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-314H<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-324H<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-315H<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-325H<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>K housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-323K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-314K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-324K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-315K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-325K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-323<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-314<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-324<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-315<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-325<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensi<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Rumah H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313H<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-323H<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-314H<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>NM-324H<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-315H<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-325H<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>K housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313K<\/td>\n<td>52<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>NM-323K<\/td>\n<td>60<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-314K<\/td>\n<td>52<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>NM-324K<\/td>\n<td>60<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-315K<\/td>\n<td>52<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>NM-325K<\/td>\n<td>60<\/td>\n<td>95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Flange 76 \u00d7 76; fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Standard housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-313<\/td>\n<td>48<\/td>\n<td>58<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-323<\/td>\n<td>63<\/td>\n<td>28<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-314<\/td>\n<td>48<\/td>\n<td>28<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-324<\/td>\n<td>63<\/td>\n<td>28<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-315<\/td>\n<td>48<\/td>\n<td>28<\/td>\n<td>86<\/td>\n<\/tr>\n<tr>\n<td>NM-325<\/td>\n<td>63<\/td>\n<td>28<\/td>\n<td>95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Flange 70 \u00d7 70; fixing centres 56 \u00d7 56; circular opening \u00d856.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-straight-panel-mounted-sockets-dimension.webp\" alt=\"IP44 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-straight-panel-mounted-sockets-dimension-02.webp\" alt=\"IP44 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-straight-panel-mounted-sockets-dimension-03.webp\" alt=\"IP44 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<h2>Panduan Pemilihan<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informasi Pemesanan<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 soket industri lurus yang dipasang di panel untuk koneksi daya industri tetap.<\/p>\n<ul>\n<li>Peringkat arus: 16 \/ 32 A.<\/li>\n<li>Susunan kontak: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Soket betina dengan penutup berengsel dan flensa pemasangan panel.<\/li>\n<li>Tabel pemilihan model lengkap mencakup tegangan, posisi kontak bumi, rentang konduktor, dan dimensi spesifik housing.<\/li>\n<li>Pilih dan tanyakan berdasarkan kode model NM lengkap.<\/li>\n<\/ul>","protected":false},"featured_media":2863,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2867","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product\/2867","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media\/2863"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media?parent=2867"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_brand?post=2867"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_cat?post=2867"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_tag?post=2867"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}