{"id":2904,"date":"2026-10-07T14:42:24","date_gmt":"2026-10-07T14:42:24","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2904"},"modified":"2026-10-07T14:42:33","modified_gmt":"2026-10-07T14:42:33","slug":"ip67-surface-mounted-industrial-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/id\/product\/ip67-surface-mounted-industrial-sockets\/","title":{"rendered":"IP67 Soket Industri Dudukan Permukaan"},"content":{"rendered":"<h2>Tinjauan<\/h2>\n<p>YOCL ELECTRIC IP67 soket industri pemasangan permukaan menyediakan titik koneksi betina tetap untuk colokan industri yang kompatibel. Seri ini mencakup peringkat 16 \/ 32 \/ 63 \/ 125 A dan susunan kontak 2P+E, 3P+E, 3P+N+E. Setiap model menggabungkan peringkat arus, tegangan, posisi kontak bumi, dan desain rumah tertentu.<\/p>\n<p>Tabel pemilihan menyatukan versi selungkup yang tersedia dalam satu keluarga produk. Gunakan kode model NM lengkap untuk menentukan konfigurasi listrik dan dimensi pemasangan yang sesuai.<\/p>\n<h2>Fitur<\/h2>\n<ul>\n<li>Selungkup belakang dan struktur pemasangan permukaan untuk pemasangan soket tetap.<\/li>\n<li>Peringkat perlindungan IP67 untuk model yang terdaftar.<\/li>\n<li>Penutup berengsel di muka soket.<\/li>\n<li>Konfigurasi biru, merah, dan kuning tercantum berdasarkan model yang tepat dalam tabel pemilihan.<\/li>\n<li>Rentang konduktor dan dimensi pemasangan spesifik model untuk memilih koneksi listrik dan ruang instalasi.<\/li>\n<li>Posisi kontak bumi alternatif terdaftar secara terpisah; cocokkan posisi bumi dengan konfigurasi colokan yang dimaksud.<\/li>\n<\/ul>\n<h2>Spesifikasi Teknis<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Spesifikasi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Merek<\/td>\n<td>YOCL ELEKTRIK<\/td>\n<\/tr>\n<tr>\n<td>Jenis produk<\/td>\n<td>IP67 Soket Industri Dudukan Permukaan<\/td>\n<\/tr>\n<tr>\n<td>Jenis Kelamin Kontak<\/td>\n<td>Soket betina<\/td>\n<\/tr>\n<tr>\n<td>Pemasangan<\/td>\n<td>Pemasangan permukaan<\/td>\n<\/tr>\n<tr>\n<td>Rating proteksi<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Pilihan arus terukur<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Susunan kontak<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Konfigurasi tegangan<\/td>\n<td>110\u2013130 V; 220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posisi kontak pentanahan<\/td>\n<td>4h \/ 6h \/ 3h<\/td>\n<\/tr>\n<tr>\n<td>Penampang konduktor<\/td>\n<td>Nilai spesifik model dalam tabel pemilihan<\/td>\n<\/tr>\n<tr>\n<td>Versi housing<\/td>\n<td>Desain housing 1, 16\/32 A; Desain housing 2, 63\/125 A; Desain housing 2, 16\/32 A; Housing standar, 63\/125 A; Konfigurasi khusus 3h<\/td>\n<\/tr>\n<tr>\n<td>Opsi model<\/td>\n<td>28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabel Pemilihan Model<\/h2>\n<p>Nilai tegangan dan arus termasuk dalam baris model yang tepat. Tanda hubung menunjukkan bahwa tidak ada nilai spesifik model yang tersedia dalam data yang diberikan.<\/p>\n<h3>Rumah desain 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Kuning<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Kuning<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6 jam<\/td>\n<td>Biru<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6 jam<\/td>\n<td>Merah<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3h special configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Arus terukur (A)<\/th>\n<th>Kontak<\/th>\n<th>Tegangan (V)<\/th>\n<th>Posisi bumi<\/th>\n<th>Warna<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>Merah<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-1242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>Merah<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensi<\/h2>\n<p>Dimension letters apply to the individual housing drawing. The same letter can identify a different feature on another housing version. Select the mounting dimensions from the exact model row.<\/p>\n<h3>Rumah desain 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>e1 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>150<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>145<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>150<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>150<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>161<\/td>\n<td>111<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 82; fixing width 71; vertical spacings 16, 48 and 40; side drawing 103.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Cable-entry drawing PG29.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-02.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-03.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-04.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-05.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<h2>Panduan Pemilihan<\/h2>\n<ol>\n<li>Choose the rated current and contact arrangement required for the connection.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informasi Pemesanan<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP67 soket industri pemasangan permukaan untuk koneksi daya industri tetap.<\/p>\n<ul>\n<li>Peringkat arus: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Susunan kontak: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Soket betina dengan penutup berengsel dan selungkup pemasangan belakang.<\/li>\n<li>Tabel pemilihan model lengkap mencakup tegangan, posisi kontak bumi, rentang konduktor, dan dimensi spesifik housing.<\/li>\n<li>Pilih dan tanyakan berdasarkan kode model NM lengkap.<\/li>\n<\/ul>","protected":false},"featured_media":2898,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2904","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product\/2904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media\/2898"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/media?parent=2904"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_brand?post=2904"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_cat?post=2904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/id\/wp-json\/wp\/v2\/product_tag?post=2904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}