
Caixa de Junção Mini à Prova de Água F1-2T IP68
entradas 2 · 16 A / 450 V · 0.5–4 mm²
Ver produtomini caixas de junção IP68 com 2–8 entradas de cabo nas gamas F1, F2, F3 e F5, mais uma caixa de interruptor basculante IP65 separada. Faça corresponder o layout da entrada, a vedação do cabo e a classificação do terminal à sua aplicação.
Explorar a gama

entradas 2 · 16 A / 450 V · 0.5–4 mm²
Ver produto
3 entries · 16 A / 450 V · 0.5–2.5 mm²
Ver produto
4 entries · 24 A / 450 V · 0.5–2.5 mm²
Ver produto
3 entries · 10 A / 450 V · 0.5–2.5 mm²
Ver produto
2 entries · 32 A / 450 V · 0.5–10 mm²
Ver produto
3 entries · 32 A / 450 V · 0.5–10 mm²
Ver produto
4 entries · 32 A / 450 V · 0.5–10 mm²
Ver produto
5 entries · 32 A / 450 V · 0.5–10 mm²
Ver produto
6 entries · 32 A / 450 V · 0.5–10 mm²
Ver produto
3 entries · 60 A / 450 V · 0.5–10 mm²
Ver produto
4 entries · 60 A / 450 V · 0.5–10 mm²
Ver produto
8 entries · 60 A / 450 V · 0.5–10 mm²
Ver produtoListed ratings apply to the specified screw-terminal configurations.
| Modelo | Entries | Current / voltage | Conductor (mm²) | Cable O.D. options (mm) |
|---|---|---|---|---|
| F1-2T | 2 | 16 A / 450 V | 0.5–4 | 3–6.5 / 5–8 / 7–10 |
| F1-3T | 3 | 16 A / 450 V | 0.5–2.5 | 3–6.5 / 5–8 / 7–10 |
| F1-4T | 4 | 24 A / 450 V | 0.5–2.5 | 3–6.5 / 5–8 / 7–10 |
| F2-3T | 3 | 10 A / 450 V | 0.5–2.5 | 5–8 / 9–12 |
| F3-2T | 2 | 32 A / 450 V | 0.5–10 | 5–8 / 9–12 / 10–14 |
| F3-3T | 3 | 32 A / 450 V | 0.5–10 | 5–8 / 9–12 |
| F3-4T | 4 | 32 A / 450 V | 0.5–10 | 5–8 / 9–12 |
| F3-5T | 5 | 32 A / 450 V | 0.5–10 | 5–8 / 9–12 |
| F3-6T | 6 | 32 A / 450 V | 0.5–10 | 5–8 / 9–12 / 10–14 |
| F5-3T | 3 | 60 A / 450 V | 0.5–10 | 5–8 / 9–12 / 10–14 |
| F5-4T | 4 | 60 A / 450 V | 0.5–10 | 5–8 / 9–12 / 10–14 |
| F5-8T | 8 | 60 A / 450 V | 0.5–10 | 5–8 / 9–12 / 10–14 |
F5-4T offers 2 + 2 and 3 + 1 entry layouts. F3-5T also has alternative layouts; confirm the arrangement when ordering.

Two cable entries, a 22 × 31 mm switch cutout and cable seals for 3–6, 5–8 or 7–10 mm outside diameters.
Choose four-terminal / two-position or six-terminal / three-position arrangements, with the specified screw-terminal or push-on connection option. Confirm the required circuit rating and whether you need the enclosure or complete switch assembly.
View switch boxChoose the number and arrangement of cable entries to suit the wiring layout.
Match each cable’s measured outside diameter to the specified sealing range.
Confirm conductor size, connection method and the terminal configuration supplied.
Check the selected model’s temperature limits and protection data for the intended environment.
The listed screw-terminal ratings are 16 A for F1-2T and F1-3T, 24 A for F1-4T, 10 A for F2-3T, 32 A for F3 models and 60 A for F5 models, all at 450 V. Match the exact model and conductor range to the circuit requirements.
The mini junction boxes are listed as IP68; the rocker switch box is IP65. Confirm the selected configuration and test conditions. Correct cable sizing, sealing and assembly remain essential.
The collection image shows a range of box and terminal options. Confirm the supplied terminal and accessories for the selected model before ordering.
Provide the series or drawing, cable-entry arrangement, cable diameters, conductor sizes, quantities and packaging requirements.