{"id":3160,"date":"2026-10-12T02:23:06","date_gmt":"2026-10-12T02:23:06","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=c21635a44e341af8d80099e3f899435c0e760ca29d9767c937286b7c6ec9f1f8"},"modified":"2026-10-12T10:33:41","modified_gmt":"2026-10-12T10:33:41","slug":"cable-tie-size-and-tensile-strength-chart","status":"publish","type":"post","link":"https:\/\/yocl.com\/pt\/cable-tie-size-and-tensile-strength-chart\/","title":{"rendered":"Tabela de Tamanhos e Resist\u00eancia \u00e0 Tra\u00e7\u00e3o de Abra\u00e7adeiras: Como Ler os Dados"},"content":{"rendered":"<p><strong>Leia cada linha de abra\u00e7adeira como quatro especifica\u00e7\u00f5es separadas: comprimento, largura real da tira, di\u00e2metro m\u00e1ximo do feixe e for\u00e7a de tra\u00e7\u00e3o declarada.<\/strong> O c\u00f3digo do modelo, por si s\u00f3, n\u00e3o pode estabelecer a adequa\u00e7\u00e3o ou a capacidade de carga.<\/p>\n<h2>Tabela de tamanho e resist\u00eancia \u00e0 tra\u00e7\u00e3o de abra\u00e7adeiras YC YOCL<\/h2>\n<p>Selecionado <a href=\"https:\/\/yocl.com\/pt\/product\/yc-standard-nylon-cable-ties\/\">Linhas de nylon padr\u00e3o YC<\/a>; as colunas de for\u00e7a mostram equivalentes de cat\u00e1logo arredondados, n\u00e3o classifica\u00e7\u00f5es de carga de trabalho.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo YC<\/th>\n<th align=\"right\">Comprimento (mm)<\/th>\n<th align=\"right\">Largura real (mm)<\/th>\n<th align=\"right\">Di\u00e2metro m\u00e1x. do feixe (mm)<\/th>\n<th align=\"right\">Tra\u00e7\u00e3o declarada (lbf)<\/th>\n<th align=\"right\">Equivalente listado (kgf)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YC-3\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">2.4<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">18<\/td>\n<td align=\"right\">8<\/td>\n<\/tr>\n<tr>\n<td>YC-4\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">3.4<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">40<\/td>\n<td align=\"right\">18<\/td>\n<\/tr>\n<tr>\n<td>YC-5\u00d7200<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">4.8<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">22<\/td>\n<\/tr>\n<tr>\n<td>YC-5\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">4.8<\/td>\n<td align=\"right\">82<\/td>\n<td align=\"right\">50<\/td>\n<td align=\"right\">22<\/td>\n<\/tr>\n<tr>\n<td>YC-8\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">7.6<\/td>\n<td align=\"right\">82<\/td>\n<td align=\"right\">120<\/td>\n<td align=\"right\">55<\/td>\n<\/tr>\n<tr>\n<td>YC-12\u00d7300<\/td>\n<td align=\"right\">300<\/td>\n<td align=\"right\">12<\/td>\n<td align=\"right\">80<\/td>\n<td align=\"right\">200<\/td>\n<td align=\"right\">91<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>YC-5<\/strong> \u00e9 um c\u00f3digo de fam\u00edlia; a largura real aqui \u00e9 <strong>4.8 mm<\/strong>.<\/p>\n<h2>Leia os quatro campos por ordem<\/h2>\n<p><strong>Comprimento<\/strong> \u00e9 o comprimento total indicado da abra\u00e7adeira. <strong>Largura<\/strong> \u00e9 a largura real da tira, lida da sua pr\u00f3pria coluna. <strong>Di\u00e2metro m\u00e1ximo do feixe<\/strong> \u00e9 o maior di\u00e2metro de feixe declarado para esse modelo. Utilize este campo de di\u00e2metro para verificar o ajuste; n\u00e3o o calcule apenas a partir do comprimento. <strong>Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/strong> \u00e9 um valor de for\u00e7a com a sua unidade indicada, n\u00e3o um tamanho de feixe ou capacidade de suporte sustentada.<\/p>\n<figure class=\"wp-block-image\">\n<img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/cable-tie-size-and-tensile-strength-chart-dimensions.webp\" alt=\"Cable tie showing overall length, strap width and bundle diameter\"><figcaption>Dimens\u00f5es conceptuais; verifique o di\u00e2metro m\u00e1ximo de feixe declarado de cada modelo.<\/figcaption><\/figure>\n<p>N\u00e3o existe um c\u00e1lculo universal de comprimento para feixe: utilize o campo de di\u00e2metro declarado do modelo. <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\">UL Orienta\u00e7\u00e3o de abra\u00e7adeiras da Solutions<\/a> trata o di\u00e2metro de feixe como um limite de sele\u00e7\u00e3o recomendado pelo fabricante.<\/p>\n<p>Considere um <strong>60 mm feixe medido<\/strong> como um exerc\u00edcio de leitura. Uma linha com um <strong>50 mm<\/strong> m\u00e1ximo falha essa verifica\u00e7\u00e3o de di\u00e2metro; um <strong>82 mm<\/strong> As folgas m\u00e1ximas que uma verifica\u00e7\u00e3o permite. A sua aprova\u00e7\u00e3o n\u00e3o estabelece quanta carga cont\u00ednua a abra\u00e7adeira pode suportar, se o seu material \u00e9 adequado ao ambiente, nem quanta margem existe para passar a ponta pela cabe\u00e7a. Mantenha o seu di\u00e2metro medido separado do limite declarado pelo fabricante; o gr\u00e1fico n\u00e3o \u00e9 uma medida da sua instala\u00e7\u00e3o.<\/p>\n<h2>Duas compara\u00e7\u00f5es que tornam o gr\u00e1fico \u00fatil<\/h2>\n<p><strong>YC-5\u00d7200 \u2192 YC-5\u00d7300:<\/strong> largura e for\u00e7a mant\u00eam-se <strong>4.8 mm \/ 50 lbf<\/strong>; o limite do feixe aumenta <strong>50 \u2192 82 mm<\/strong>.<\/p>\n<p><strong>YC-5\u00d7300 \u2192 YC-8\u00d7300:<\/strong> ambos s\u00e3o <strong>300 mm<\/strong> longo com um <strong>82 mm<\/strong> limite de feixe; a largura aumenta <strong>4.8 \u2192 7.6 mm<\/strong> e for\u00e7a declarada <strong>50 \u2192 120 lbf<\/strong>. Estes pares de cat\u00e1logo n\u00e3o estabelecem uma f\u00f3rmula de largura para resist\u00eancia.<\/p>\n<p>Para qualquer nova compara\u00e7\u00e3o, copie o <strong>linha inteira<\/strong> para cada modelo e marca exatos, e indicar o que se manteve igual, o que mudou e o que a tabela deixa por saber. Retirar o comprimento de uma linha, a largura de outra e a for\u00e7a de uma terceira pode criar uma especifica\u00e7\u00e3o que nenhum modelo listado possui de facto.<\/p>\n<h2>Ler lbf, kgf e N sem misturar for\u00e7a com massa<\/h2>\n<p><strong>lbf<\/strong> significa libra-for\u00e7a; <strong>kgf<\/strong> significa quilograma-for\u00e7a. Ambas s\u00e3o unidades de for\u00e7a. Um quilograma (kg) por si s\u00f3 \u00e9 uma unidade de massa, pelo que substituir \u201ckgf\u201d por \u201ckg\u201d altera o significado da coluna. O Instituto Nacional de Normas e Tecnologia dos EUA (NIST) lista <strong>1 lbf \u2248 4.448222 N<\/strong> e <strong>1 kgf = 9.80665 N<\/strong>. <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\">Fatores de convers\u00e3o de for\u00e7a NIST SP 811<\/a>.<\/p>\n<p>Por exemplo, <strong>50 lbf \u00d7 4.448222 \u2248 222 N<\/strong>. Para uma especifica\u00e7\u00e3o controlada, solicite a base de teste do modelo exato.<\/p>\n<p>A unidade tamb\u00e9m importa quando os n\u00fameros impressos parecem id\u00eanticos. Um exemplo ilustrativo <strong>10 lbf \u2248 44.5 N<\/strong>, enquanto <strong>10 kgf \u2248 98.1 N<\/strong>: os dois valores designados por \u201c10\u201d n\u00e3o s\u00e3o a mesma for\u00e7a. Converta para uma unidade comum antes de comparar tabelas, mas mantenha a entrada original e a sua unidade ao lado do seu c\u00e1lculo. D\u00edgitos extra no valor convertido n\u00e3o aumentam a precis\u00e3o da declara\u00e7\u00e3o original do produto. Uma convers\u00e3o apenas padroniza a unidade; n\u00e3o pode recuperar um m\u00e9todo de teste em falta ou transformar uma entrada de tra\u00e7\u00e3o numa carga cont\u00ednua admiss\u00edvel. <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\">Fatores de convers\u00e3o de for\u00e7a NIST<\/a>.<\/p>\n<h2>For\u00e7a n\u00e3o \u00e9 tens\u00e3o de material<\/h2>\n<p>Um valor em lbf ou kgf descreve <strong>for\u00e7a<\/strong>; uma folha de dados de material pode descrever em vez disso a tra\u00e7\u00e3o <strong>tens\u00e3o<\/strong> em megapascals (MPa). Estas s\u00e3o quantidades diferentes: <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-330\/sp-330-section-2\" target=\"_blank\" rel=\"noopener\">NIST&#8217;s SI table<\/a> gives the newton (N) for force and the pascal (Pa), equivalent to N\/m\u00b2, for stress. Strap width by itself is not a cross-sectional area. Dividing a listed tie force by width, or multiplying a material-stress value by width, therefore cannot produce a valid rating for a different tie. Keep the complete-tie declaration and any material property in separate fields until the relevant test basis is known.<\/p>\n<h2>What the tensile entry establishes<\/h2>\n<p>\u201cTensile strength\u201d needs a defined specimen and test condition. The International Electrotechnical Commission (IEC) defines <strong>resist\u00eancia \u00e0 tra\u00e7\u00e3o do la\u00e7o<\/strong> for a cable tie with its lock engaged. Its IEC 62275:2022 public preview also says a loop tensile value does <strong>descreve<\/strong> indicate long-term static load-bearing capability. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\">IEC 62275:2022 public preview, Sections 3.7 and 6.2.1<\/a>.<\/p>\n<p>YC lists <strong>\u201cTensile strength\u201d<\/strong> without a row-specific test method; the table alone cannot establish IEC testing. UL Solutions also distinguishes a locked tie\u2019s loop result from material strength and long-term support. <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\">UL cable-tie guidance<\/a>.<\/p>\n<p>The distinction is practical when two suppliers print similar force figures. The public IEC preview describes type-test specimens installed according to the manufacturer&#8217;s instructions; it also addresses stabilization of non-metallic samples, ambient conditions and a mandrel arrangement for mechanical tests. Those details show why the <strong>specimen, conditioning and test method<\/strong> matter to a comparison. They are requirements of the IEC method, not evidence that YOCL&#8217;s YC entries were obtained by that method. Ask whether a reported figure is a declared minimum loop result, another statistic or simply a catalogue heading before treating two numbers as comparable. <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\">IEC 62275:2022 public preview, Section 5<\/a>.<\/p>\n<p>The table also cannot decide exposure suitability. Material, operating temperature, installation conditions and ultraviolet exposure require their own exact product information. For those separate choices, see <a href=\"https:\/\/yocl.com\/pt\/nylon-vs-stainless-steel-cable-ties\/\">abra\u00e7adeiras de nylon versus a\u00e7o inoxid\u00e1vel<\/a> e <a href=\"https:\/\/yocl.com\/pt\/uv-resistant-vs-standard-cable-ties\/\">UV-resistente versus la\u00e7os de cabo padr\u00e3o<\/a>.<\/p>\n<h2>Keep the exact-model record intact<\/h2>\n<p>When copying a chart entry into a drawing or purchase specification, keep the full model code, original units, listed dimensions, source page and retrieval date together. If a field is blank, write <strong>\u201cnot stated\u201d<\/strong>; a neighboring length or width does not fill it. Record your measured bundle diameter separately from the manufacturer&#8217;s maximum and from the evidence still needed for the application. For a force-sensitive use, that missing evidence may include the test method, specimen condition and approved service limits. This record makes an enquiry precise and prevents a later unit conversion or catalogue revision from hiding the original claim.<\/p>\n<p>Utilizar o <a href=\"https:\/\/yocl.com\/pt\/cable-ties-manufacturer\/\">gama de bra\u00e7adeiras YOCL<\/a> to compare the selected material and construction. Include the measured bundle diameter, intended environment and exact model when requesting its complete strength and test documentation.<\/p>\n<p><strong>Leitura relacionada:<\/strong> <a href=\"https:\/\/yocl.com\/pt\/why-do-nylon-cable-ties-break\/\">troubleshooting broken nylon ties<\/a>.<\/p>\n<h2>Refer\u00eancias<\/h2>\n<ul>\n<li>YOCL EL\u00c9TRICA, <a href=\"https:\/\/yocl.com\/pt\/product\/yc-standard-nylon-cable-ties\/\"><em>Abra\u00e7adeiras de Nylon YC Standard<\/em><\/a>, model table, checked 12 October 2026.<\/li>\n<li>UL Solutions, <a href=\"https:\/\/www.ul.com\/services\/cable-ties-cable-management\" target=\"_blank\" rel=\"noopener\"><em>Cable Ties and Cable Management<\/em><\/a>, bundling diameter, loop strength and application limits.<\/li>\n<li>National Institute of Standards and Technology, <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-appendix-b-conversion-factors\/nist-guide-si-appendix-b9\" target=\"_blank\" rel=\"noopener\"><em>Guide for the Use of the International System of Units (SI), SP 811, Appendix B.9: Force<\/em><\/a>, lbf and kgf conversion factors.<\/li>\n<li>National Institute of Standards and Technology, <a href=\"https:\/\/www.nist.gov\/pml\/special-publication-330\/sp-330-section-2\" target=\"_blank\" rel=\"noopener\"><em>The International System of Units (SI), SP 330, Section 2<\/em><\/a>, SI units for force and stress.<\/li>\n<li>IEC, <a href=\"https:\/\/cdn.standards.iteh.ai\/samples\/104902\/2cd16dcb98e242f1b56333a5ddb4c06e\/IEC-62275-2022.pdf\" target=\"_blank\" rel=\"noopener\"><em>IEC 62275:2022 \u2014 public preview<\/em><\/a>, Sections 3.7, 5.1\u20135.3, 5.9 and 6.2.1; consulted preview sections only.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Read each cable tie row as four separate specifications: length, actual strap width, maximum bundle diameter and declared tensile force. The model code alone cannot establish fit or load capacity. YOCL YC cable tie size and tensile strength chart Selected YC standard nylon rows; force columns show rounded catalogue equivalents, not working-load ratings. YC model [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3159,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[163],"tags":[],"class_list":["post-3160","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cable-ties-cable-management"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts\/3160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/comments?post=3160"}],"version-history":[{"count":0,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts\/3160\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/3159"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=3160"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/categories?post=3160"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/tags?post=3160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}