{"id":3509,"date":"2026-11-18T07:11:25","date_gmt":"2026-11-18T07:11:25","guid":{"rendered":"https:\/\/yocl.com\/?wpr2_import=1c507a41b93f835c8d127c1309a252cd75bf9e083efdbb24e728a8e17ea57d14"},"modified":"2026-11-18T07:11:25","modified_gmt":"2026-11-18T07:11:25","slug":"bell-mouth-cable-lugs","status":"publish","type":"post","link":"https:\/\/yocl.com\/pt\/bell-mouth-cable-lugs\/","title":{"rendered":"Terminais de Cabos com Boca de Sino: Porque a Entrada Alargada do Corpo Importa para Condutores Multifilares"},"content":{"rendered":"<p><strong>Terminais de cabos com boca de sino<\/strong> s\u00e3o terminais tubulares de compress\u00e3o de cobre formados com uma abertura em forma de funil, alargada na parte traseira do corpo do condutor, para recolher e guiar os fios de cobre multifilares de forma limpa para o interior. Na s\u00e9rie SC(JGB) da YOCL ELECTRIC, os modelos 16 cobrem condutores de 6\u2013630 mm\u00b2.<\/p>\n<p>A maioria das especifica\u00e7\u00f5es de terminais de cabos foca-se no furo do parafuso da pala e no furo do corpo, tratando a boca traseira do corpo como um corte quadrado simples. No entanto, em cabos multifilares, a borda de entrada decide se cada fio de cobre entra na zona de crimpagem ou se prende na borda durante a montagem. Para manter os t\u00f3picos vizinhos distintos, o procedimento de crimpagem (comprimento da decapagem, profundidade de inser\u00e7\u00e3o, coloca\u00e7\u00e3o da crimpagem e verifica\u00e7\u00f5es p\u00f3s-crimpagem) pertence a <a href=\"https:\/\/yocl.com\/pt\/how-to-crimp-cable-lugs\/\">como crimpar terminais de cabos<\/a>, a sele\u00e7\u00e3o de ferramentas pertence a <a href=\"https:\/\/yocl.com\/pt\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">como combinar terminais de cabo, matrizes de crimpagem e condutores<\/a>, e o dimensionamento geral do furo para o condutor pertence a <a href=\"https:\/\/yocl.com\/pt\/cable-lug-size-chart\/\">a tabela de tamanhos de terminais de cabo<\/a>. As fam\u00edlias de terminais com janela de inspe\u00e7\u00e3o ou orif\u00edcio de inspe\u00e7\u00e3o \u2014 tais como a YOCL\u2019s SC(JGK) e a s\u00e9rie JM\/JGY \u2014 destinam-se \u00e0 verifica\u00e7\u00e3o visual da profundidade e n\u00e3o \u00e0 geometria de entrada do condutor, sendo uma caracter\u00edstica distinta do corpo do terminal.<\/p>\n<h2>O problema da inser\u00e7\u00e3o de condutores entran\u00e7ados numa entrada de terminal reta<\/h2>\n<p>Um condutor de cobre entran\u00e7ado comporta-se como um feixe el\u00e1stico de fios individuais e n\u00e3o como uma haste r\u00edgida. Quando empurrado contra uma entrada de terminal com corte reto de 90 graus, os fios exteriores prendem-se facilmente no rebordo do terminal, espalham-se para fora ou dobram-se ao longo da parede exterior em vez de entrarem no orif\u00edcio.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-entry-comparison.webp\" width=\"1920\" height=\"1080\" alt=\"Conceptual outline diagram comparing a stranded copper conductor catching and splaying on a straight-cut barrel mouth versus entering smoothly through a flared bell mouth into bore d.\" \/><figcaption>Numa entrada de terminal com corte reto, os fios exteriores num feixe entran\u00e7ado el\u00e1stico podem prender-se no rebordo quadrado e espalhar-se para fora; uma entrada em sino funciona como um funil que guia todo o feixe para o interior do orif\u00edcio d.<\/figcaption><\/figure>\n<p>Na oficina ou dentro de um quadro el\u00e9trico, o bloqueio de fios numa entrada de terminal reta cria dois defeitos mec\u00e2nicos imediatos antes mesmo de a ferramenta de crava\u00e7\u00e3o tocar no terminal:<\/p>\n<ul>\n<li><strong>Fios presos fora do terminal:<\/strong> Uma vez removido o isolamento de um cabo entran\u00e7ado, a camada exterior de fios relaxa ligeiramente para fora. Se o di\u00e2metro interior do terminal <strong>d<\/strong> \u00e9 ajustado de perto ao feixe de condutores, mesmo uma ligeira entrada em \u00e2ngulo contra uma extremidade de corte quadrado prende um ou mais fios exteriores. Esses fios que escapam dobram-se para fora da parede do terminal \u2014 reduzindo a sec\u00e7\u00e3o transversal do condutor capturada dentro da uni\u00e3o e deixando filamentos de cobre expostos que podem desviar-se para terminais de fase adjacentes ou estruturas met\u00e1licas ligadas \u00e0 terra.<\/li>\n<li><strong>Profundidade de inser\u00e7\u00e3o incompleta:<\/strong> Mesmo quando um fio preso n\u00e3o se dobra totalmente para o exterior do tubo, o amontoamento na extremidade do terminal prende o feixe e impede que o condutor atinja a profundidade total de assentamento dentro do terminal.<\/li>\n<li><strong>Porque \u00e9 que as sec\u00e7\u00f5es transversais maiores oferecem maior resist\u00eancia:<\/strong> Em <strong>6 mm\u00b2<\/strong>, um fio de cobre de baixa tor\u00e7\u00e3o \u00e9 f\u00e1cil de torcer entre dois dedos e inserir num tubo reto. A partir de <strong>95 mm\u00b2<\/strong> e acima \u2014 atrav\u00e9s de <strong>185 mm\u00b2<\/strong>, <strong>300 mm\u00b2<\/strong>, e <strong>630 mm\u00b2<\/strong>\u2014a rigidez dos cabos pesados, os raios de curvatura apertados nos inv\u00f3lucros e o maior n\u00famero de fios tornam o alinhamento coaxial perfeito muito mais dif\u00edcil de manter manualmente, pelo que as extremidades quadradas dos terminais prendem os fios com muito mais facilidade durante a montagem.<\/li>\n<\/ul>\n<h2>O que a entrada do terminal alargada altera \u2014 e o que n\u00e3o altera<\/h2>\n<p>Uma boca de sino \u00e9 um funil c\u00f3nico suave formado na extremidade de entrada do terminal de cobre: como refere a especifica\u00e7\u00e3o do produto YOCL\u2019s SC(JGB), a abertura alargada ajuda a guiar os condutores \u2014 incluindo condutores de cobre entran\u00e7ados \u2014 para dentro do terminal. A jusante desse rebordo de entrada, a estrutura da uni\u00e3o mec\u00e2nica e el\u00e9trica do terminal permanece inalterada.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-jgb-vs-jga.webp\" width=\"1920\" height=\"1080\" alt=\"Catalogue studio comparison of YOCL SC(JGB) bell mouth flared-entry copper cable lug and SC(JGA) standard straight-entry copper cable lug.\" \/><figcaption>Comparando os terminais de cobre com boca de sino YOCL SC(JGB) com os terminais de cobre de entrada padr\u00e3o SC(JGA): o funil alargado altera apenas a entrada do condutor, enquanto o di\u00e2metro interno do terminal, a zona de crava\u00e7\u00e3o e a patilha de um furo permanecem iguais em termos de fun\u00e7\u00e3o.<\/figcaption><\/figure>\n<p>Separar o que o alargamento altera do que permanece id\u00eantico evita interpreta\u00e7\u00f5es excessivas da geometria do cat\u00e1logo:<\/p>\n<ul>\n<li><strong>O que o alargamento altera (entrada de montagem):<\/strong> Em vez de apresentar um rebordo anelar plano \u00e0 extremidade do fio descarnado, a boca alargada alarga a abertura alvo e afunila suavemente para dentro em dire\u00e7\u00e3o ao orif\u00edcio cil\u00edndrico. Os fios exteriores ligeiramente soltos contactam uma rampa inclinada que re\u00fane o conjunto de fios e guia o feixe coaxialmente para dentro do tubo.<\/li>\n<li><strong>O que permanece id\u00eantico a jusante:<\/strong> Para al\u00e9m do afunilamento de entrada curto, o di\u00e2metro interno do corpo cil\u00edndrico (<strong>d<\/strong> na tabela abaixo), o di\u00e2metro externo do corpo (<strong>D<\/strong>), a zona de crava\u00e7\u00e3o por compress\u00e3o, a sele\u00e7\u00e3o da matriz e a patilha de montagem plana de um orif\u00edcio funcionam exatamente da mesma forma que nos terminais de entrada reta padr\u00e3o da YOCL. <a href=\"https:\/\/yocl.com\/pt\/product\/sc-jga-copper-cable-lugs\/\">SC(JGA) terminais de cobre<\/a>.<\/li>\n<li><strong>Uma funcionalidade de inser\u00e7\u00e3o, nunca uma melhoria el\u00e9trica:<\/strong> A YOCL n\u00e3o publica qualquer classifica\u00e7\u00e3o de corrente, valor de tra\u00e7\u00e3o ou classifica\u00e7\u00e3o de temperatura para a s\u00e9rie SC(JGB, e a boca afunilada nunca deve ser considerada como tendo maior capacidade de corrente, menor resist\u00eancia de contacto ou temperaturas de funcionamento mais baixas. A qualidade da uni\u00e3o el\u00e9trica prov\u00e9m do ajuste correto entre o condutor e o di\u00e2metro interno e da compress\u00e3o a frio do corpo \u2014 a boca em sino serve simplesmente para garantir que todos os fios entram efetivamente nesse corpo antes da crava\u00e7\u00e3o.<\/li>\n<\/ul>\n<h2>Tabela de tamanhos de terminais de cabo com boca em sino: YOCL S\u00e9rie SC(JGB (6\u2013630 mm\u00b2)<\/h2>\n<p>Especifica\u00e7\u00e3o <strong>terminais de cabo com entrada em funil<\/strong> em YOCL ELECTRIC <a href=\"https:\/\/yocl.com\/pt\/product\/sc-jgb-bell-mouth-copper-cable-lugs\/\">SC(JGB) terminais de cabo de cobre com entrada em funil<\/a> a gama abrange modelos de cobre 16 a partir de <strong>SC(JGB)-6<\/strong> para <strong>SC(JGB)-630<\/strong>, where each model suffix identifies nominal copper conductor cross-section in mm\u00b2 and every dimensional column is given in millimetres.<\/p>\n<figure class=\"wp-block-image\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/11\/bell-mouth-cable-lugs-dimension-guide.webp\" width=\"1920\" height=\"1080\" alt=\"Orthographic dimension drawing for YOCL SC(JGB) bell mouth copper cable lugs showing overall length L, barrel inner diameter d, barrel outer diameter D, palm width B, and fixed mounting-hole \u03a6 range options.\" \/><figcaption>YOCL SC(JGB) dimension definitions: d is barrel inner bore, D is barrel outer diameter, L is overall length, B is palm width, and the \u03a6 range lists fixed hole diameters available per model at order time.<\/figcaption><\/figure>\n<h3>Understanding the Mounting-Hole \u03a6-Range Rule Before Ordering<\/h3>\n<p>Look carefully at the <strong>Mounting-Hole \u03a6 Range (mm)<\/strong> column in the SC(JGB) table below. Each row prints a millimetre range\u2014such as <strong>6.4\u20138.4 mm<\/strong> on <strong>SC(JGB)-6<\/strong> ou <strong>10.5\u201318.5 mm<\/strong> on <strong>SC(JGB)-240<\/strong>\u2014because each conductor model is manufactured in multiple fixed stud-hole diameters within that span.<\/p>\n<p>As stated on YOCL&#8217;s SC(JGB) product page, <strong>that range represents the available hole sizes for the model, not an adjustable, slotted, or one-size-fits-all hole<\/strong>. Every supplied lug has a single round mounting hole punched to one specific diameter. When requesting a quotation or placing an order, specify three items together:<\/p>\n<ol>\n<li><strong>Complete model code<\/strong> (for example, <strong>SC(JGB)-95<\/strong> ou <strong>SC(JGB)-240<\/strong>);<\/li>\n<li><strong>Required mounting-hole diameter<\/strong> (chosen from that model&#8217;s published <strong>\u03a6<\/strong> range to match your equipment bolt or stud);<\/li>\n<li><strong>Order quantity<\/strong>.<\/li>\n<\/ol>\n<h3>Complete YOCL SC(JGB) Dimensional Specification Table (16 Models)<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Mounting-Hole \u03a6 Range \u2014 Available Hole Sizes (mm)<\/th>\n<th>D Barrel Outer (mm)<\/th>\n<th>d Barrel Inner (mm)<\/th>\n<th>L Overall (mm)<\/th>\n<th>B Palm Width (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>SC(JGB)-6<\/strong><\/td>\n<td>6.4\u20138.4<\/td>\n<td>5.5<\/td>\n<td>4.5<\/td>\n<td>23<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-10<\/strong><\/td>\n<td>6.4\u20138.4<\/td>\n<td>6.5<\/td>\n<td>5.5<\/td>\n<td>27<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-16<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>8<\/td>\n<td>6.6<\/td>\n<td>33<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-25<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>9<\/td>\n<td>7.2<\/td>\n<td>36<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-35<\/strong><\/td>\n<td>6.4\u201312.5<\/td>\n<td>10.5<\/td>\n<td>8.7<\/td>\n<td>42<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-50<\/strong><\/td>\n<td>8.4\u201312.5<\/td>\n<td>12<\/td>\n<td>10<\/td>\n<td>49<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-70<\/strong><\/td>\n<td>8.4\u201312.5<\/td>\n<td>14.5<\/td>\n<td>12.1<\/td>\n<td>55<\/td>\n<td>21<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-95<\/strong><\/td>\n<td>8.4\u201316.5<\/td>\n<td>16<\/td>\n<td>13.2<\/td>\n<td>59<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-120<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>19<\/td>\n<td>15.6<\/td>\n<td>67<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-150<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>20.5<\/td>\n<td>16.9<\/td>\n<td>72<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-185<\/strong><\/td>\n<td>10.5\u201316.5<\/td>\n<td>23.5<\/td>\n<td>19.5<\/td>\n<td>78<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-240<\/strong><\/td>\n<td>10.5\u201318.5<\/td>\n<td>26<\/td>\n<td>21.4<\/td>\n<td>90<\/td>\n<td>38<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-300<\/strong><\/td>\n<td>10.5\u201318.5<\/td>\n<td>30<\/td>\n<td>24.4<\/td>\n<td>100<\/td>\n<td>42<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-400<\/strong><\/td>\n<td>10.5\u201320.5<\/td>\n<td>34<\/td>\n<td>28.2<\/td>\n<td>113<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-500<\/strong><\/td>\n<td>12.5\u201322.5<\/td>\n<td>38<\/td>\n<td>32<\/td>\n<td>126<\/td>\n<td>54<\/td>\n<\/tr>\n<tr>\n<td><strong>SC(JGB)-630<\/strong><\/td>\n<td>12.5\u201322.5<\/td>\n<td>45<\/td>\n<td>37.8<\/td>\n<td>145<\/td>\n<td>65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Regra de Sele\u00e7\u00e3o:<\/strong> Match nominal copper conductor cross-section to the <strong>SC(JGB)<\/strong> model suffix first, verify stripped conductor clearance against barrel inner diameter <strong>d<\/strong> (de <strong>4.5 mm<\/strong> at 6 mm\u00b2 up to <strong>37.8 mm<\/strong> at 630 mm\u00b2), specify the exact fixed mounting-hole diameter from the row&#8217;s <strong>\u03a6<\/strong> range for your terminal bolt, and check overall length <strong>L<\/strong> (23\u2013145 mm) and palm width <strong>B<\/strong> (10\u201365 mm) against terminal compartment barriers. For the general bore-and-stud sizing method across lug families, see <a href=\"https:\/\/yocl.com\/pt\/cable-lug-size-chart\/\">a tabela de tamanhos de terminais de cabo<\/a>.<\/p>\n<p>For example, terminating a <strong>95 mm\u00b2<\/strong> stranded copper feeder selects <strong>SC(JGB)-95<\/strong> (<strong>d = 13.2 mm<\/strong>, <strong>D = 16 mm<\/strong>, <strong>L = 59 mm<\/strong>, <strong>B = 24 mm<\/strong>), and the buyer specifies the exact required bolt-hole diameter within <strong>8.4\u201316.5 mm<\/strong> at order time; stepping up to a <strong>240 mm\u00b2<\/strong> feeder selects <strong>SC(JGB)-240<\/strong> (<strong>d = 21.4 mm<\/strong>, <strong>D = 26 mm<\/strong>, <strong>L = 90 mm<\/strong>, <strong>B = 38 mm<\/strong>) with its fixed hole chosen within <strong>10.5\u201318.5 mm<\/strong>.<\/p>\n<h2>When Bell Mouth Lugs Earn Their Place \u2014 and When Straight Entry Is Fine<\/h2>\n<p>Flared-entry lugs are the practical answer to a specific wire-insertion problem rather than an automatic replacement for every straight-entry lug on a bill of materials. Matching the barrel mouth to conductor construction and assembly workflow keeps selection grounded:<\/p>\n<ul>\n<li><strong>Where bell mouth lugs earn their place:<\/strong><\/li>\n<li><strong>Stranded and flexible multi-wire copper conductors:<\/strong> The higher the wire count and the finer the individual copper strands, the more readily the stripped end mushrooms or catches on a square tube edge.<\/li>\n<li><strong>Larger cable cross-sections:<\/strong> On heavy feeders\u2014such as <strong>95 mm\u00b2<\/strong> (<strong>d = 13.2 mm<\/strong>), <strong>185 mm\u00b2<\/strong> (<strong>d = 19.5 mm<\/strong>), <strong>300 mm\u00b2<\/strong> (<strong>d = 24.4 mm<\/strong>), and <strong>630 mm\u00b2<\/strong> (<strong>d = 37.8 mm<\/strong>)\u2014guiding a stiff cable end onto a lug inside a tight termination box benefits directly from a funnelled entry.<\/li>\n<li><strong>Repetitive panel and harness production:<\/strong> When an assembly line terminates hundreds of cable ends per shift, every snagged strand forces the operator to pull the cable out, re-lay the wires, and repeat the insertion. A flared entry cuts down that repetitive assembly rework.<\/li>\n<li><strong>When a standard straight entry is completely adequate:<\/strong><\/li>\n<li><strong>Solid copper conductors:<\/strong> A single solid wire has no individual strands to splay or fold back at the mouth.<\/li>\n<li><strong>Small stranded conductors that seat cleanly:<\/strong> On compact sizes such as <strong>6 mm\u00b2<\/strong> ou <strong>10 mm\u00b2<\/strong> where a neatly stripped conductor slips straight into bore <strong>d<\/strong> without catching, a standard straight-entry lug performs the termination without difficulty.<\/li>\n<li><strong>Undisturbed bench terminations verified by trial fit:<\/strong> If the stripped conductor will not be bent or handled roughly between stripping and crimping, and a dry trial fit confirms the wire bundle enters the barrel cleanly to full depth, barrel entry geometry is not your bottleneck.<\/li>\n<\/ul>\n<h2>Insertion Practice with a Flared Barrel Entry<\/h2>\n<p>A flared mouth guides strands inward, but it does not excuse careless wire preparation or blind crimping. Follow three assembly habits whenever terminating stranded copper conductors into an SC(JGB) lug:<\/p>\n<ol>\n<li><strong>Re-twist the strand lay by hand after stripping:<\/strong> Pulling off tough cable insulation often untwists or ruffles the outer copper layer. Before presenting the wire to the lug, gently twist the stripped strands in the natural direction of their lay so the bundle enters the bell mouth as a single coherent cylinder.<\/li>\n<li><strong>Seat the conductor fully home before compressing:<\/strong> Push the cable smoothly through the flare until the conductor reaches full insertion depth inside the barrel; for strip-length matching, seating depth criteria, and crimp placement along the barrel, follow <a href=\"https:\/\/yocl.com\/pt\/how-to-crimp-cable-lugs\/\">como crimpar terminais de cabos<\/a>.<\/li>\n<li><strong>Inspect the bell mouth rim before closing the crimping tool:<\/strong> Pause and look all the way around the flared entry lip before applying pressure. <strong>Zero strands may sit outside the flare.<\/strong> Any wire resting outside the bell mouth is outside the crimp barrel\u2014closing the die over it locks a reduced-section joint and a loose external copper whisker permanently in place. If even one strand escapes, withdraw the cable, re-form the lay, and insert again before crimping.<\/li>\n<\/ol>\n<h2>Perguntas Frequentes<\/h2>\n<h3>Does a bell mouth cable lug carry more current than a standard lug?<\/h3>\n<p>No. YOCL publishes no current rating, tensile figure, or temperature rating for the SC(JGB) series, and the flared mouth provides no ampacity, resistance, or thermal advantage over a straight-entry lug. Electrical joint quality is determined by proper bore fit (<strong>d<\/strong>) and barrel compression, which match standard copper tube lugs in form.<\/p>\n<h3>Is the mounting hole on an SC(JGB) lug adjustable?<\/h3>\n<p>No. The <strong>Mounting-Hole \u03a6 Range<\/strong> in the SC(JGB) chart (<strong>6.4\u20138.4 mm<\/strong> through <strong>12.5\u201322.5 mm<\/strong>) lists the range of fixed circular hole diameters manufactured for each model\u2014never a slotted or adjustable hole. Specify the model code, the exact required mounting-hole diameter, and quantity when ordering.<\/p>\n<h3>Do I need different crimp dies for bell mouth cable lugs?<\/h3>\n<p>The crimp is made on the cylindrical barrel body downstream of the flared mouth, just as on straight-entry copper cable lugs (<strong>D<\/strong> das <strong>5.5 mm<\/strong> para <strong>45 mm<\/strong> e <strong>d<\/strong> das <strong>4.5 mm<\/strong> para <strong>37.8 mm<\/strong> across 6\u2013630 mm\u00b2). Do not assume a special bell-mouth die; follow <a href=\"https:\/\/yocl.com\/pt\/how-to-match-cable-lugs-crimp-dies-and-conductors\/\">como combinar terminais de cabo, matrizes de crimpagem e condutores<\/a>.<\/p>\n<h3>Should I choose a bell mouth lug or a peephole lug?<\/h3>\n<p>They solve two different assembly tasks. A bell mouth lug (<strong>SC(JGB)<\/strong>) flares the rear barrel entry to guide multi-wire stranded conductors smoothly into the bore without splaying strands, whereas a peephole lug (such as YOCL&#8217;s <strong>SC(JGK<\/strong> ou <strong>JM\/JGY<\/strong> series) provides an inspection hole to check conductor seating depth before crimping.<\/p>\n<h2>Refer\u00eancias<\/h2>\n<ul>\n<li><strong>Informa\u00e7\u00e3o do Produto EL\u00c9TRICO YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/pt\/product\/sc-jgb-bell-mouth-copper-cable-lugs\/\">SC(JGB) Anilhas de Cobre para Cabos com Boca de Sino<\/a>: flared-entry copper lug specifications, mounting-hole \u03a6-range ordering rules, and 16-model dimensional table (6\u2013630 mm\u00b2).<\/li>\n<li><strong>Informa\u00e7\u00e3o do Produto EL\u00c9TRICO YOCL<\/strong> \u2014 <a href=\"https:\/\/yocl.com\/pt\/product\/sc-jga-copper-cable-lugs\/\">SC(JGA) Anilhas de Cobre para Cabos<\/a>: standard straight-entry copper tube cable lug counterpart series (6\u2013630 mm\u00b2).<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Bell mouth cable lugs are copper compression tube terminals formed with a funnel-shaped, flared opening at the rear of the conductor barrel to gather and guide multi-wire copper strands cleanly into the bore. Across YOCL ELECTRIC&#8217;s SC(JGB) series, 16 models cover 6\u2013630 mm\u00b2 conductors. Most cable-lug specifications focus on the palm bolt hole and barrel [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3508,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[164],"tags":[],"class_list":["post-3509","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-terminals-connections"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts\/3509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/comments?post=3509"}],"version-history":[{"count":1,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts\/3509\/revisions"}],"predecessor-version":[{"id":3510,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/posts\/3509\/revisions\/3510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/3508"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=3509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/categories?post=3509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/tags?post=3509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}