{"id":1826,"date":"2026-10-02T16:55:08","date_gmt":"2026-10-02T16:55:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1826"},"modified":"2026-10-02T16:55:14","modified_gmt":"2026-10-02T16:55:14","slug":"hswh-f4x-4-1-flame-retardant-dual-wall-heat-shrink-tubing","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/hswh-f4x-4-1-flame-retardant-dual-wall-heat-shrink-tubing\/","title":{"rendered":"HSWH-F4X 4:1 Tubo Termoretr\u00e1til de Parede Dupla com Alta Retard\u00e2ncia \u00e0 Chama"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>YOCL El\u00e9trico <strong>HSWH-F4X 4:1 Tubo Termoretr\u00e1til de Parede Dupla com Alta Retard\u00e2ncia \u00e0 Chama<\/strong> proporciona isolamento e selagem adesiva para cablagens de autom\u00f3veis, emendas e liga\u00e7\u00f5es el\u00e9tricas. Combina uma parede exterior de poliolefina retardadora de chama com uma camada interior de adesivo termofus\u00edvel.<\/p>\n<p>Durante o aquecimento, a parede exterior encolhe e o adesivo amolece e flui em torno do cabo ou componente. Ap\u00f3s o arrefecimento, o adesivo ajuda a formar uma interface selada contra \u00e1gua e humidade. O nominal <strong>4:1 taxa de encolhimento<\/strong> acomoda transi\u00e7\u00f5es de di\u00e2metro conetor-cabo. Seis tamanhos standard s\u00e3o fornecidos em <strong>1.22 m de comprimento<\/strong>.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Parede exterior retardadora de chama:<\/strong> Especificado para passar no teste de retardamento de chama ASTM D2671.<\/li>\n<li><strong>4:1 recupera\u00e7\u00e3o nominal:<\/strong> Permite a instala\u00e7\u00e3o sobre conetores antes de encolher em cabos mais pequenos.<\/li>\n<li><strong>Veda\u00e7\u00e3o adesiva de dupla parede:<\/strong> Combina isolamento exterior com um adesivo termofus\u00edvel interior.<\/li>\n<li><strong>Prote\u00e7\u00e3o de cablagens autom\u00f3veis:<\/strong> Adequado para emendas de fios, ramifica\u00e7\u00f5es de cablagens e liga\u00e7\u00f5es el\u00e9tricas.<\/li>\n<li><strong>Intervalo de opera\u00e7\u00e3o de -45\u00b0C a +125\u00b0C:<\/strong> Suporta a sele\u00e7\u00e3o para a temperatura de servi\u00e7o pretendida.<\/li>\n<li><strong>Resist\u00eancia a UV e cores standard:<\/strong> Parede exterior preta com revestimento adesivo branco.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL El\u00e9trico<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9rie<\/td>\n<td>HSWH-F4X<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>Tubo termo-retr\u00e1til com revestimento adesivo de dupla parede, com elevada retard\u00e2ncia \u00e0 chama<\/td>\n<\/tr>\n<tr>\n<td>Aplica\u00e7\u00e3o principal<\/td>\n<td>Feixes de cabos autom\u00f3veis<\/td>\n<\/tr>\n<tr>\n<td>Taxa de encolhimento<\/td>\n<td>4:1 nominal<\/td>\n<\/tr>\n<tr>\n<td>Camada exterior<\/td>\n<td>Poliolefina ign\u00edfuga<\/td>\n<\/tr>\n<tr>\n<td>Camada interior<\/td>\n<td>Adesivo termofus\u00edvel<\/td>\n<\/tr>\n<tr>\n<td>Temperatura inicial de encolhimento<\/td>\n<td>\u226570\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de encolhimento total<\/td>\n<td>\u2265125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de opera\u00e7\u00e3o<\/td>\n<td>-45\u00b0C a +125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>UV resist\u00eancia<\/td>\n<td>Sim<\/td>\n<\/tr>\n<tr>\n<td>Norma ambiental<\/td>\n<td>RoHS<\/td>\n<\/tr>\n<tr>\n<td>Cor exterior padr\u00e3o<\/td>\n<td>Preto<\/td>\n<\/tr>\n<tr>\n<td>Cor do adesivo padr\u00e3o<\/td>\n<td>Branco<\/td>\n<\/tr>\n<tr>\n<td>Comprimento standard<\/td>\n<td>1.22 m<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de tamanhos listados<\/td>\n<td>6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Desempenho da Camada Exterior<\/h3>\n<table>\n<thead>\n<tr>\n<th>Propriedade<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<th>M\u00e9todo ou condi\u00e7\u00e3o de teste<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/td>\n<td>\u226510.4 MPa<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Alongamento \u00e0 rutura<\/td>\n<td>\u2265300%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o ap\u00f3s envelhecimento<\/td>\n<td>\u22657.3 MPa<\/td>\n<td>158\u00b0C durante 168 horas<\/td>\n<\/tr>\n<tr>\n<td>Alongamento ap\u00f3s envelhecimento<\/td>\n<td>\u2265100%<\/td>\n<td>158\u00b0C durante 168 horas<\/td>\n<\/tr>\n<tr>\n<td>Altera\u00e7\u00e3o axial<\/td>\n<td>-8% a +8%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Retard\u00e2ncia \u00e0 chama<\/td>\n<td>Aprovado<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Rigidez diel\u00e9trica<\/td>\n<td>\u226515 kV\/mm<\/td>\n<td>IEC 60243<\/td>\n<\/tr>\n<tr>\n<td>Resistividade volum\u00e9trica<\/td>\n<td>\u226510\u00b9\u2074 \u03a9\u00b7cm<\/td>\n<td>IEC 60093<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 158\u00b0C exposure is an aging test condition. The stated operating temperature range is -45\u00b0C to +125\u00b0C.<\/p>\n<h3>Hot-Melt Adhesive Performance<\/h3>\n<table>\n<thead>\n<tr>\n<th>Propriedade<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<th>M\u00e9todo de teste<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Softening point<\/td>\n<td>90 \u00b1 5\u00b0C<\/td>\n<td>ASTM E28<\/td>\n<\/tr>\n<tr>\n<td>Absor\u00e7\u00e3o de \u00e1gua<\/td>\n<td>&lt;0.2%<\/td>\n<td>ASTM D570<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<table>\n<thead>\n<tr>\n<th>Nominal size (mm)<\/th>\n<th>Supplied I.D. (mm)<\/th>\n<th>Max. I.D. after recovery (mm)<\/th>\n<th>Total wall thickness (mm)<\/th>\n<th>Adhesive layer thickness (mm)<\/th>\n<th>Standard length (m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>4.0<\/td>\n<td>\u22654.0<\/td>\n<td>\u22640.95<\/td>\n<td>1.40 \u00b1 0.30<\/td>\n<td>0.60 \u00b1 0.20<\/td>\n<td>1.22<\/td>\n<\/tr>\n<tr>\n<td>6.0<\/td>\n<td>\u22656.0<\/td>\n<td>\u22641.27<\/td>\n<td>1.70 \u00b1 0.30<\/td>\n<td>0.80 \u00b1 0.20<\/td>\n<td>1.22<\/td>\n<\/tr>\n<tr>\n<td>8.0<\/td>\n<td>\u22658.0<\/td>\n<td>\u22641.65<\/td>\n<td>2.00 \u00b1 0.30<\/td>\n<td>0.95 \u00b1 0.20<\/td>\n<td>1.22<\/td>\n<\/tr>\n<tr>\n<td>10.0<\/td>\n<td>\u226510.0<\/td>\n<td>\u22642.00<\/td>\n<td>2.30 \u00b1 0.40<\/td>\n<td>1.10 \u00b1 0.20<\/td>\n<td>1.22<\/td>\n<\/tr>\n<tr>\n<td>12.0<\/td>\n<td>\u226512.0<\/td>\n<td>\u22642.41<\/td>\n<td>2.45 \u00b1 0.40<\/td>\n<td>1.20 \u00b1 0.20<\/td>\n<td>1.22<\/td>\n<\/tr>\n<tr>\n<td>18.0<\/td>\n<td>\u226518.0<\/td>\n<td>\u22644.45<\/td>\n<td>2.60 \u00b1 0.40<\/td>\n<td>1.34 \u00b1 0.30<\/td>\n<td>1.22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I.D. means internal diameter. Diameters and thicknesses are in millimetres; standard lengths are in metres. The \u2265 values specify minimum supplied internal diameters, and the \u2264 values specify maximum internal diameters after recovery.<\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Select a supplied diameter that can pass over the largest connector, terminal or component. Then check the specified maximum recovered I.D., total wall thickness and adhesive layer thickness for the cable or joint being covered.<\/p>\n<p>Use the dimensions for the selected size when assessing fit. For example, the 8.0 mm size has a supplied I.D. of at least 8.0 mm and a maximum recovered I.D. of 1.65 mm. Its total wall thickness is 2.00 \u00b1 0.30 mm and adhesive layer thickness is 0.95 \u00b1 0.20 mm.<\/p>\n<p>Check the initial and full shrink temperatures for installation and the operating range for service. The standard construction has a black outer wall and white adhesive.<\/p>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<ul>\n<li>Automotive wire harnesses and harness branches.<\/li>\n<li>Wire splices and wire-to-wire joints.<\/li>\n<li>Connector and terminal insulation.<\/li>\n<li>Cable repair and moisture protection for electrical connections.<\/li>\n<\/ul>\n<h2>Notas de Instala\u00e7\u00e3o<\/h2>\n<ol>\n<li>Select an HSWH-F4X size that can pass over the connector, terminal or component.<\/li>\n<li>Cut the tubing to the required length, slide it over the harness and position it over the area to be protected.<\/li>\n<li>Apply controlled heat evenly around the tubing.<\/li>\n<li>Continue heating until the outer wall has recovered and the adhesive has flowed around the underlying surface.<\/li>\n<li>Remove the heat source and allow the tubing and adhesive to cool completely.<\/li>\n<li>Check for uniform recovery and sealing.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Especificar <strong>HSWH-F4X<\/strong>, the required nominal size and quantity when making an enquiry to YOCL Electric. The standard length is <strong>1.22 m<\/strong>, com um <strong>black outer wall<\/strong> e <strong>white hot-melt adhesive<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL El\u00e9trico HSWH-F4X proporciona isolamento retardador de chama e selagem adesiva para cablagens de autom\u00f3veis, emendas e conectores.<\/p>\n<ul>\n<li>4 Nominal: 1 taxa de encolhimento com constru\u00e7\u00e3o de parede dupla.<\/li>\n<li>Parede exterior de poliolefina retardadora de chama e revestimento interior de adesivo termofus\u00edvel.<\/li>\n<li>Seis tamanhos de 4 mm a 18 mm fornecidos I.D.; comprimento padr\u00e3o 1.22 m.<\/li>\n<li>Temperatura inicial de encolhimento \u226570\u00b0C; temperatura de encolhimento total \u2265125\u00b0C.<\/li>\n<li>Intervalo de opera\u00e7\u00e3o -45\u00b0C a +125\u00b0C; parede exterior preta e adesivo branco.<\/li>\n<\/ul>","protected":false},"featured_media":1825,"template":"","meta":[],"product_brand":[],"product_cat":[94],"product_tag":[],"class_list":["post-1826","product","type-product","status-publish","has-post-thumbnail","product_cat-adhesive-heat-shrink","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/1826","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/1825"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=1826"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1826"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1826"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1826"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}