{"id":1830,"date":"2026-10-02T17:06:19","date_gmt":"2026-10-02T17:06:19","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=1830"},"modified":"2026-10-02T17:06:25","modified_gmt":"2026-10-02T17:06:25","slug":"hsne-f-2-1-flame-retardant-ev-busbar-heat-shrink-tubing","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/hsne-f-2-1-flame-retardant-ev-busbar-heat-shrink-tubing\/","title":{"rendered":"HSNE-F 2:1 Tubo Termorretr\u00e1til Ign\u00edfugo para Barra de Barramento EV"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>YOCL El\u00e9trico <strong>HSNE-F 2:1 Tubo Termorretr\u00e1til Ign\u00edfugo para Barra de Barramento EV<\/strong> fornece isolamento el\u00e9trico e prote\u00e7\u00e3o de superf\u00edcie para barramentos de ve\u00edculos de nova energia, barras de cobre e conex\u00f5es el\u00e9tricas. A s\u00e9rie \u00e9 feita de poliolefina reticulada por radia\u00e7\u00e3o com uma constru\u00e7\u00e3o de parede \u00fanica.<\/p>\n<p>Seu <strong>2:1 taxa de encolhimento<\/strong> permite que o tubo recupere em torno de componentes condutores e \u00e1reas de conex\u00e3o. Dezoito tamanhos cobrem di\u00e2metros nominais de 10\/5 mm a 50\/25 mm. HSNE-F tem uma <strong>classifica\u00e7\u00e3o de chama VW-1<\/strong>, uma faixa de opera\u00e7\u00e3o de <strong>-55\u00b0C a +125\u00b0C<\/strong> e um padr\u00e3o <strong>cor laranja<\/strong>.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Isolamento de barramento EV:<\/strong> Adequado para barras de cobre, barramentos laminados e conex\u00f5es el\u00e9tricas de bateria.<\/li>\n<li><strong>2:1 constru\u00e7\u00e3o de parede \u00fanica:<\/strong> Forma uma cobertura isolante justa \u00e0 volta do componente.<\/li>\n<li><strong>VW-1 desempenho \u00e0 chama:<\/strong> Especificado com a ASTM D2671 como m\u00e9todo de teste.<\/li>\n<li><strong>Propriedades el\u00e9tricas definidas:<\/strong> As especifica\u00e7\u00f5es de tens\u00e3o de suporte, rigidez diel\u00e9trica e resistividade est\u00e3o listadas abaixo.<\/li>\n<li><strong>Cor laranja padr\u00e3o:<\/strong> Suporta a identifica\u00e7\u00e3o visual em sistemas el\u00e9tricos de ve\u00edculos; cores personalizadas est\u00e3o dispon\u00edveis.<\/li>\n<li><strong>Dezoito op\u00e7\u00f5es de tamanho:<\/strong> Os di\u00e2metros fornecidos, paredes recuperadas, comprimentos de embalagem e intervalos de aplica\u00e7\u00e3o est\u00e3o listados por tamanho.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL El\u00e9trico<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9rie<\/td>\n<td>HSNE-F<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>Tubo termo-retr\u00e1til de parede \u00fanica, retardador de chama<\/td>\n<\/tr>\n<tr>\n<td>Aplica\u00e7\u00e3o principal<\/td>\n<td>Barramentos e conex\u00f5es el\u00e9tricas de ve\u00edculos de nova energia<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>Poliolefina reticulada por radia\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Constru\u00e7\u00e3o<\/td>\n<td>Parede \u00fanica<\/td>\n<\/tr>\n<tr>\n<td>Taxa de encolhimento<\/td>\n<td>2:1<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de opera\u00e7\u00e3o<\/td>\n<td>-55\u00b0C a +125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura inicial de encolhimento<\/td>\n<td>\u226585\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de encolhimento total<\/td>\n<td>\u2265125\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Cor padr\u00e3o<\/td>\n<td>Laranja<\/td>\n<\/tr>\n<tr>\n<td>Cores personalizadas<\/td>\n<td>Dispon\u00edvel<\/td>\n<\/tr>\n<tr>\n<td>Norma ambiental<\/td>\n<td>RoHS<\/td>\n<\/tr>\n<tr>\n<td>Intervalo de tamanho nominal<\/td>\n<td>10\/5 mm a 50\/25 mm<\/td>\n<\/tr>\n<tr>\n<td>Embalagem standard<\/td>\n<td>100 m, 50 m ou 25 m, dependendo do tamanho<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de tamanhos listados<\/td>\n<td>18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Desempenho Mec\u00e2nico e de Chama<\/h3>\n<table>\n<thead>\n<tr>\n<th>Propriedade<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<th>M\u00e9todo ou condi\u00e7\u00e3o de teste<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/td>\n<td>\u226510.4 MPa<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Alongamento \u00e0 rutura<\/td>\n<td>\u2265200%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Resist\u00eancia \u00e0 tra\u00e7\u00e3o ap\u00f3s envelhecimento<\/td>\n<td>\u22657.3 MPa<\/td>\n<td>158\u00b0C durante 168 horas<\/td>\n<\/tr>\n<tr>\n<td>Alongamento ap\u00f3s envelhecimento<\/td>\n<td>\u2265100%<\/td>\n<td>158\u00b0C durante 168 horas<\/td>\n<\/tr>\n<tr>\n<td>Altera\u00e7\u00e3o axial<\/td>\n<td>-5% para +5%<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<tr>\n<td>Retard\u00e2ncia \u00e0 chama<\/td>\n<td>VW-1<\/td>\n<td>ASTM D2671<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A exposi\u00e7\u00e3o 158\u00b0C \u00e9 uma condi\u00e7\u00e3o de teste de envelhecimento. A gama de temperatura de opera\u00e7\u00e3o indicada \u00e9 de -55\u00b0C a +125\u00b0C.<\/p>\n<h3>Desempenho El\u00e9trico<\/h3>\n<table>\n<thead>\n<tr>\n<th>Propriedade<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<th>M\u00e9todo de teste<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tens\u00e3o de suportabilidade (600 V)<\/td>\n<td>2500 V durante 1 minuto; sem rutura<\/td>\n<td>UL224<\/td>\n<\/tr>\n<tr>\n<td>Rigidez diel\u00e9trica<\/td>\n<td>\u226515 kV\/mm<\/td>\n<td>ASTM D149<\/td>\n<\/tr>\n<tr>\n<td>Resistividade volum\u00e9trica<\/td>\n<td>\u226510\u00b9\u2074 \u03a9\u00b7cm<\/td>\n<td>IEC 60093<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<table>\n<thead>\n<tr>\n<th>Nominal size (mm)<\/th>\n<th>Supplied I.D. (mm)<\/th>\n<th>Max. I.D. after recovery (mm)<\/th>\n<th>Wall thickness after recovery (mm)<\/th>\n<th>Standard packing (m)<\/th>\n<th>Application range (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10\/5<\/td>\n<td>10.5 \u00b1 0.30<\/td>\n<td>\u22645.00<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>5.3\u201310.1<\/td>\n<\/tr>\n<tr>\n<td>11\/5.5<\/td>\n<td>11.5 \u00b1 0.30<\/td>\n<td>\u22645.50<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>5.8\u201311.1<\/td>\n<\/tr>\n<tr>\n<td>12\/6<\/td>\n<td>12.5 \u00b1 0.30<\/td>\n<td>\u22646.00<\/td>\n<td>0.56 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>6.3\u201312.1<\/td>\n<\/tr>\n<tr>\n<td>13\/6.5<\/td>\n<td>13.5 \u00b1 0.30<\/td>\n<td>\u22646.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>6.8\u201313.1<\/td>\n<\/tr>\n<tr>\n<td>14\/7<\/td>\n<td>14.5 \u00b1 0.30<\/td>\n<td>\u22647.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>7.3\u201314.1<\/td>\n<\/tr>\n<tr>\n<td>15\/7.5<\/td>\n<td>15.5 \u00b1 0.40<\/td>\n<td>\u22647.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>7.8\u201315.1<\/td>\n<\/tr>\n<tr>\n<td>16\/8<\/td>\n<td>16.5 \u00b1 0.40<\/td>\n<td>\u22648.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>8.3\u201316.1<\/td>\n<\/tr>\n<tr>\n<td>17\/8.5<\/td>\n<td>17.5 \u00b1 0.40<\/td>\n<td>\u22648.50<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>8.8\u201317.1<\/td>\n<\/tr>\n<tr>\n<td>18\/9<\/td>\n<td>19.0 \u00b1 0.50<\/td>\n<td>\u22649.00<\/td>\n<td>0.70 \u00b1 0.10<\/td>\n<td>100<\/td>\n<td>9.3\u201318.1<\/td>\n<\/tr>\n<tr>\n<td>20\/10<\/td>\n<td>22.0 \u00b1 0.50<\/td>\n<td>\u226410.00<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<td>100<\/td>\n<td>10.5\u201321.0<\/td>\n<\/tr>\n<tr>\n<td>22\/11<\/td>\n<td>24.0 \u00b1 0.50<\/td>\n<td>\u226411.00<\/td>\n<td>0.80 \u00b1 0.15<\/td>\n<td>100<\/td>\n<td>11.5\u201323.0<\/td>\n<\/tr>\n<tr>\n<td>25\/12.5<\/td>\n<td>26.0 \u00b1 0.50<\/td>\n<td>\u226412.50<\/td>\n<td>0.90 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>13.0\u201325.0<\/td>\n<\/tr>\n<tr>\n<td>28\/14<\/td>\n<td>29.0 \u00b1 0.50<\/td>\n<td>\u226414.00<\/td>\n<td>0.90 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>14.5\u201327.0<\/td>\n<\/tr>\n<tr>\n<td>30\/15<\/td>\n<td>31.5 \u00b1 1.00<\/td>\n<td>\u226415.00<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>17.0\u201329.0<\/td>\n<\/tr>\n<tr>\n<td>35\/17.5<\/td>\n<td>36.5 \u00b1 1.00<\/td>\n<td>\u226417.50<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>20.0\u201330.0<\/td>\n<\/tr>\n<tr>\n<td>40\/20<\/td>\n<td>41.5 \u00b1 1.00<\/td>\n<td>\u226420.00<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>50<\/td>\n<td>22.0\u201335.0<\/td>\n<\/tr>\n<tr>\n<td>45\/22.5<\/td>\n<td>46.5 \u00b1 1.50<\/td>\n<td>\u226422.50<\/td>\n<td>1.00 \u00b1 0.15<\/td>\n<td>25<\/td>\n<td>30\u201345<\/td>\n<\/tr>\n<tr>\n<td>50\/25<\/td>\n<td>\u226550<\/td>\n<td>\u226425.00<\/td>\n<td>1.10 \u00b1 0.15<\/td>\n<td>25<\/td>\n<td>28\u201345<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I.D. means internal diameter. Diameters, wall thicknesses and application ranges are in millimetres; packing lengths are in metres. The \u2264 values specify maximum recovered internal diameters. The 50\/25 mm size has a minimum supplied I.D. of 50 mm.<\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Use the application range for the selected size together with its supplied I.D., maximum recovered I.D. and recovered wall thickness. For example, the 20\/10 mm option has a supplied I.D. of 22.0 \u00b1 0.50 mm, a maximum recovered I.D. of 10.00 mm and a recovered wall thickness of 0.80 \u00b1 0.15 mm. Its application range is 10.5\u201321.0 mm.<\/p>\n<p>Check fit over the busbar, connection or component before choosing a size. Review the packing length for that row: 100 m for sizes 10\/5 through 22\/11, 50 m for 25\/12.5 through 40\/20, and 25 m for 45\/22.5 and 50\/25.<\/p>\n<p>Specify the required color and quantity with the selected size. Orange is the standard color; other colors can be requested for project requirements.<\/p>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<ul>\n<li>EV and hybrid vehicle battery systems.<\/li>\n<li>Copper and laminated busbar insulation.<\/li>\n<li>Battery electrical connections and conductive components.<\/li>\n<li>Solder-joint protection against corrosion.<\/li>\n<li>Electrical connection and component covering.<\/li>\n<\/ul>\n<h2>Notas de Instala\u00e7\u00e3o<\/h2>\n<ol>\n<li>Measure the busbar, conductor or component requiring insulation.<\/li>\n<li>Select HSNE-F tubing using the application range and dimensional table.<\/li>\n<li>Cut the tubing to the required length and slide it into position.<\/li>\n<li>Aplique calor controlado uniformemente \u00e0 volta do tubo at\u00e9 que este recupere uniformemente.<\/li>\n<li>Remove the heat source and allow the tubing to cool.<\/li>\n<li>Inspect the recovered tubing for complete and uniform coverage.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Especificar <strong>HSNE-F<\/strong>, the selected nominal size, required color and quantity when making an enquiry to YOCL Electric. Standard packing is <strong>100 m, 50 m or 25 m<\/strong> according to the size table.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL El\u00e9trico HSNE-F fornece isolamento de parede \u00fanica retardador de chama para barramentos de EV, barras de cobre e conex\u00f5es el\u00e9tricas.<\/p>\n<ul>\n<li>Poliolefina reticulada por radia\u00e7\u00e3o com uma 2:1 taxa de encolhimento.<\/li>\n<li>Classifica\u00e7\u00e3o de inflamabilidade VW-1; intervalo de opera\u00e7\u00e3o de -55\u00b0C a +125\u00b0C.<\/li>\n<li>Temperatura inicial de encolhimento \u226585\u00b0C; temperatura de encolhimento total \u2265125\u00b0C.<\/li>\n<li>Dezoito tamanhos de 10\/5 mm a 50\/25 mm, com comprimentos de embalagem especificados por tamanho.<\/li>\n<li>Cor laranja padr\u00e3o; cores personalizadas dispon\u00edveis.<\/li>\n<\/ul>","protected":false},"featured_media":1829,"template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-1830","product","type-product","status-publish","has-post-thumbnail","product_cat-single-wall-heat-shrink-tubing","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/1830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/1829"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=1830"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1830"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1830"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}