{"id":2039,"date":"2026-10-04T08:38:03","date_gmt":"2026-10-04T08:38:03","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2039"},"modified":"2026-10-04T08:38:12","modified_gmt":"2026-10-04T08:38:12","slug":"sv-series-unipolar-junction-blocks","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/sv-series-unipolar-junction-blocks\/","title":{"rendered":"Blocos de Jun\u00e7\u00e3o Unipolares S\u00e9rie SV"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p><strong>YOCL Electric SV series unipolar junction blocks<\/strong> connect main conductors to multiple branch conductors for single-pole power distribution inside electrical panels, distribution boards and control cabinets.<\/p>\n<p>The series includes <strong>SV-35 at 125 A<\/strong> and <strong>SV-95 at 232 A<\/strong>, both rated <strong>500 V<\/strong>. Each block has <strong>two main conductor openings<\/strong> and <strong>four branch conductor openings<\/strong> in an insulated housing.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Single-pole distribution<\/strong> with separate main and branch conductor connections.<\/li>\n<li><strong>Two main and four branch openings<\/strong>, giving six connection openings per block.<\/li>\n<li><strong>Two current ratings:<\/strong> 125 A for SV-35 and 232 A for SV-95.<\/li>\n<li><strong>Main conductor capacity up to 95 mm\u00b2<\/strong> and branch conductor capacity up to 16 mm\u00b2 on SV-95.<\/li>\n<li><strong>Insulated junction-block construction<\/strong> for organized panel connections.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Brand<\/td>\n<td>YOCL El\u00e9trico<\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>SV<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Unipolar junction block \/ power distribution block<\/td>\n<\/tr>\n<tr>\n<td>Pole configuration<\/td>\n<td>Single pole<\/td>\n<\/tr>\n<tr>\n<td>Rated voltage<\/td>\n<td>500 V<\/td>\n<\/tr>\n<tr>\n<td>Main conductor openings<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Branch conductor openings<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Total connection openings<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Constru\u00e7\u00e3o<\/td>\n<td>Insulated housing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Model Comparison<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Rated current (A)<\/th>\n<th>Rated voltage (V)<\/th>\n<th>Main conductor range (mm\u00b2)<\/th>\n<th>Branch conductor range (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SV-35<\/td>\n<td>125<\/td>\n<td>500<\/td>\n<td>10\u201335<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>SV-95<\/td>\n<td>232<\/td>\n<td>500<\/td>\n<td>70\u201395<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SV-35<\/td>\n<td>69 \u00d7 43 \u00d7 39<\/td>\n<\/tr>\n<tr>\n<td>SV-95<\/td>\n<td>71.5 \u00d7 57.2 \u00d7 57.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Select <strong>SV-35<\/strong> for a 125 A rating, main conductors of <strong>10\u201335 mm\u00b2<\/strong> and branch conductors of <strong>2.5\u20136 mm\u00b2<\/strong>. Select <strong>SV-95<\/strong> for a 232 A rating, main conductors of <strong>70\u201395 mm\u00b2<\/strong> and branch conductors of <strong>6\u201316 mm\u00b2<\/strong>.<\/p>\n<p>Compare the main and branch conductor ranges together with the required circuit rating and available panel space. Both models provide two main openings and four branch openings.<\/p>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<ul>\n<li>Electrical distribution panels and distribution boards<\/li>\n<li>Control and power distribution cabinets<\/li>\n<li>Machinery and industrial equipment wiring<\/li>\n<li>Industrial automation panels<\/li>\n<\/ul>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Provide the <strong>SV model<\/strong>, <strong>quantity<\/strong>, <strong>required circuit current and voltage<\/strong>, and <strong>main and branch conductor sizes<\/strong> when requesting a quotation from <strong>YOCL El\u00e9trico<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Electric SV series unipolar junction blocks distribute a single electrical pole between main and branch conductors in electrical panels. SV-35 is rated 125 A and SV-95 is rated 232 A, both at 500 V. Each model has two main conductor openings and four branch openings. Choose the model by its current rating and separate conductor ranges.<\/p>\n<ul>\n<li>Two SV models with insulated housings<\/li>\n<li>Main conductor capacity up to 95 mm\u00b2 on SV-95<\/li>\n<li>Branch conductor capacity up to 16 mm\u00b2 on SV-95<\/li>\n<li>Six connection openings per block<\/li>\n<\/ul>","protected":false},"featured_media":2038,"template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-2039","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-distribution-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2038"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2039"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2039"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2039"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}