{"id":2748,"date":"2026-10-07T10:22:50","date_gmt":"2026-10-07T10:22:50","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2748"},"modified":"2026-10-07T10:22:58","modified_gmt":"2026-10-07T10:22:58","slug":"ycc02-pole-branching-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ycc02-pole-branching-connectors\/","title":{"rendered":"Conectores de ramifica\u00e7\u00e3o de polo el\u00e9tricos YOCL YCC02"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>Os conectores de ramifica\u00e7\u00e3o de YOCL polos YCC02 ELECTRIC fornecem configura\u00e7\u00f5es de liga\u00e7\u00e3o de dois, tr\u00eas, quatro ou seis furos para cabos de alum\u00ednio e cobre. Os modelos Standard e -E t\u00eam especifica\u00e7\u00f5es de liga\u00e7\u00e3o adicional diferentes. As designa\u00e7\u00f5es de modelos cinzento, azul e amarelo\/verde s\u00e3o listadas separadamente para que o conector exato possa ser selecionado.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>As especifica\u00e7\u00f5es dos condutores de alum\u00ednio e cobre s\u00e3o listadas separadamente.<\/li>\n<li>Formas de dois, tr\u00eas, quatro e seis furos.<\/li>\n<li>Vers\u00f5es de conector Standard e -E.<\/li>\n<li>Tampa em poliamida; corpo em alum\u00ednio estanhado ou lat\u00e3o e parafusos em ferro estanhado ou lat\u00e3o.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tens\u00e3o nominal<\/td>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<td>Corrente nominal<\/td>\n<td>Al: 145 A; Cu: 135 A<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00e3o sem kit de veda\u00e7\u00e3o<\/td>\n<td>IP23<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00e3o com kit de veda\u00e7\u00e3o<\/td>\n<td>IP33<\/td>\n<\/tr>\n<tr>\n<td>Temperatura m\u00ednima de instala\u00e7\u00e3o<\/td>\n<td>+5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de opera\u00e7\u00e3o<\/td>\n<td>\u221225 a +80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Material da tampa<\/td>\n<td>Poliamida<\/td>\n<\/tr>\n<tr>\n<td>Corpo<\/td>\n<td>Alum\u00ednio ou lat\u00e3o, estanhado<\/td>\n<\/tr>\n<tr>\n<td>Parafusos<\/td>\n<td>Ferro ou lat\u00e3o, estanhado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Especifica\u00e7\u00f5es do modelo<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Cor<\/th>\n<th>Holes<\/th>\n<th>Al conductor specification (mm\u00b2)<\/th>\n<th>Cu conductor specification (mm\u00b2)<\/th>\n<th>Additional connection specification (mm\u00b2)<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Current Al\/Cu (A)<\/th>\n<th>Torque specifications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>YCC02-2-GY<\/td>\n<td>Cinza<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-BE<\/td>\n<td>Azul<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-GY-E<\/td>\n<td>Cinza<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-BE-E<\/td>\n<td>Azul<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-2-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>2<\/td>\n<td>2\u00d750<\/td>\n<td>2\u00d735<\/td>\n<td>1\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-GY<\/td>\n<td>Cinza<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-BE<\/td>\n<td>Azul<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-GY-E<\/td>\n<td>Cinza<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-BE-E<\/td>\n<td>Azul<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-3-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>3<\/td>\n<td>3\u00d750<\/td>\n<td>3\u00d735<\/td>\n<td>2\u00d76<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>2 N\u00b7m at 1.5\u20136 mm\u00b2 (M6), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-GY<\/td>\n<td>Cinza<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-BE<\/td>\n<td>Azul<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-GY-E<\/td>\n<td>Cinza<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-BE-E<\/td>\n<td>Azul<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-4-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>4<\/td>\n<td>4\u00d750<\/td>\n<td>4\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-GY<\/td>\n<td>Cinza<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-BE<\/td>\n<td>Azul<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-PE<\/td>\n<td>Yellow\/Green<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>N\u00e3o especificado<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-GY-E<\/td>\n<td>Cinza<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-BE-E<\/td>\n<td>Azul<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<tr>\n<td>YCC02-6-PE-E<\/td>\n<td>Yellow\/Green<\/td>\n<td>6<\/td>\n<td>6\u00d750<\/td>\n<td>6\u00d735<\/td>\n<td>3\u00d72.5<\/td>\n<td>1000<\/td>\n<td>145 \/ 135<\/td>\n<td>1 N\u00b7m at 1.5\u20132.5 mm\u00b2 (M4), LED; 3 N\u00b7m at 2.5\u201316 mm\u00b2 (M10); 8 N\u00b7m at 25\u201350 mm\u00b2 (M10)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Choose hole arrangement, colour designation and standard or -E version together. The conductor entries are the specified cross-sections and quantities; they are not a substitute for an unstated conductor range. Apply the torque for the relevant screw size and conductor cross-section. IP33 applies with the sealing kit.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Specify the exact model, quantity and conductor requirements when requesting a quotation. Select a complete model row; ratings and connection capacities are not interchangeable between models.<\/p>","protected":false},"excerpt":{"rendered":"<p>Conectores de ramifica\u00e7\u00e3o de YCC02 polos para condutores Al\/Cu.<\/p>\n<ul>\n<li>Configura\u00e7\u00f5es de dois, tr\u00eas, quatro ou seis furos.<\/li>\n<li>1000 V; corrente nominal Al 145 A \/ Cu 135 A.<\/li>\n<li>Modelos Standard e -E com liga\u00e7\u00f5es adicionais distintas.<\/li>\n<li>IP23 sem kit de selagem; IP33 com kit de selagem.<\/li>\n<li>Designa\u00e7\u00f5es de modelos cinzento, azul e amarelo\/verde.<\/li>\n<\/ul>","protected":false},"featured_media":2743,"template":"","meta":[],"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-2748","product","type-product","status-publish","has-post-thumbnail","product_cat-modular-distribution-blocks","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2743"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2748"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2748"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2748"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}