{"id":2818,"date":"2026-10-07T12:47:57","date_gmt":"2026-10-07T12:47:57","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2818"},"modified":"2026-10-07T12:48:05","modified_gmt":"2026-10-07T12:48:05","slug":"sp17-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/sp17-waterproof-circular-connectors\/","title":{"rendered":"Conectores Circulares \u00e0 Prova de \u00c1gua SP17"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p><strong>YOCL EL\u00c9TRICOS SP17 conectores circulares \u00e0 prova de \u00e1gua<\/strong> utilizam um acoplamento roscado para ligar cabos a recept\u00e1culos de cabo ou de painel correspondentes. A s\u00e9rie inclui fichas de cabo retas e em \u00e2ngulo reto, um recept\u00e1culo de cabo em linha e quatro formatos de recept\u00e1culo de painel.<\/p>\n<p>SP17 oferece <strong>Contactos 2, 3, 4, 5, 7, 9 ou 10<\/strong>. As configura\u00e7\u00f5es de contacto de solda t\u00eam uma classifica\u00e7\u00e3o de 10 A para 2 e 3 contactos, ou 5 A para 4, 5, 7, 9 e 10 contactos. A tens\u00e3o de trabalho tamb\u00e9m varia com o n\u00famero de contactos. Selecione o arranjo de contactos, a termina\u00e7\u00e3o e o formato de acoplamento em conjunto utilizando as tabelas abaixo.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Acoplamento roscado<\/strong> mant\u00e9m a ficha e o recept\u00e1culo correspondentes.<\/li>\n<li><strong>Sete arranjos de contactos<\/strong> cobrem 2, 3, 4, 5, 7, 9 e 10 contactos.<\/li>\n<li><strong>IP68 grau de prote\u00e7\u00e3o<\/strong> com componentes de veda\u00e7\u00e3o de cabos e tampas de conectores apresentados para a s\u00e9rie.<\/li>\n<li><strong>Contactos de cobre banhados a ouro<\/strong> e um isolador de PPS.<\/li>\n<li><strong>Fichas retas e em \u00e2ngulo reto<\/strong> suportam diferentes dire\u00e7\u00f5es de sa\u00edda de cabo.<\/li>\n<li><strong>Formatos de recept\u00e1culo de cabo e painel<\/strong> permitem liga\u00e7\u00f5es em linha ou montagem em equipamento.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<h3>Dados da S\u00e9rie<\/h3>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9rie<\/td>\n<td>SP17<\/td>\n<\/tr>\n<tr>\n<td>Acoplamento<\/td>\n<td>Bloqueio de rosca<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de contactos<\/td>\n<td>2, 3, 4, 5, 7, 9, 10<\/td>\n<\/tr>\n<tr>\n<td>Material de contacto<\/td>\n<td>Cobre banhado a ouro<\/td>\n<\/tr>\n<tr>\n<td>Material da caixa<\/td>\n<td>PC \/ PA66 termopl\u00e1stico<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de inflamabilidade da caixa<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Isolador<\/td>\n<td>PPS termopl\u00e1stico<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td>IP68<\/td>\n<\/tr>\n<tr>\n<td>Intervalo de temperatura<\/td>\n<td>\u221240 \u00b0C a +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ciclos de acoplamento<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Resist\u00eancia de isolamento<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de termina\u00e7\u00e3o<\/td>\n<td>Solda e crimpagem, dependendo do conector selecionado<\/td>\n<\/tr>\n<tr>\n<td>Di\u00e2metro exterior do cabo do plugue de cabo reto \/ recept\u00e1culo de cabo em linha<\/td>\n<td>6\u201310 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A designa\u00e7\u00e3o IP68 n\u00e3o especifica uma profundidade ou dura\u00e7\u00e3o de imers\u00e3o nos dados fornecidos. Corresponder a veda\u00e7\u00e3o do cabo ao conector selecionado e ao di\u00e2metro exterior do cabo.<\/p>\n<h3>Classifica\u00e7\u00f5es de contacto de solda<\/h3>\n<p>Os seguintes dados el\u00e9tricos e de condutor aplicam-se \u00e0s <strong>configura\u00e7\u00f5es de contacto de solda<\/strong>. N\u00e3o s\u00e3o uma tabela de classifica\u00e7\u00e3o separada para configura\u00e7\u00f5es de crimpagem ou outras termina\u00e7\u00f5es.<\/p>\n<table>\n<thead>\n<tr>\n<th>Contactos<\/th>\n<th>Corrente nominal<\/th>\n<th>Di\u00e2metro \u00d7 quantidade de contactos<\/th>\n<th>Tens\u00e3o de trabalho<\/th>\n<th>AC tens\u00e3o de suportabilidade, 1 minuto<\/th>\n<th>Resist\u00eancia de contacto<\/th>\n<th>Sec\u00e7\u00e3o m\u00e1xima do condutor<\/th>\n<th>Valor emparelhado AWG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>10 A<\/td>\n<td>\u00d81.5 mm \u00d7 2<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>2.5 m\u03a9<\/td>\n<td>\u2264 2 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>10 A<\/td>\n<td>\u00d81.5 mm \u00d7 3<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>2.5 m\u03a9<\/td>\n<td>\u2264 2 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 4<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 5<\/td>\n<td>500 V AC<\/td>\n<td>1500 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 7<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 9<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>5 A<\/td>\n<td>\u00d81.0 mm \u00d7 10<\/td>\n<td>400 V AC<\/td>\n<td>1200 V AC<\/td>\n<td>5 m\u03a9<\/td>\n<td>\u2264 0.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Os limites do condutor e os valores emparelhados AWG s\u00e3o mantidos conforme listado. Os valores AWG n\u00e3o s\u00e3o um intervalo de tamanho adicional convertido independentemente. A tens\u00e3o de resist\u00eancia de 1 minutos \u00e9 um par\u00e2metro de teste, separado da tens\u00e3o de trabalho.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp17-waterproof-circular-connectors-dimension.webp\" alt=\"SP17 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp17-waterproof-circular-connectors-dimension-02.webp\" alt=\"SP17 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p>As dimens\u00f5es abaixo est\u00e3o em <strong>mil\u00edmetros<\/strong>. As dimens\u00f5es do corpo e as aberturas do painel descrevem caracter\u00edsticas diferentes e devem ser verificadas para o formato escolhido.<\/p>\n<h3>Dimens\u00f5es do Corpo do Conetor<\/h3>\n<table>\n<thead>\n<tr>\n<th>Formato<\/th>\n<th>Modelo base<\/th>\n<th>Dimens\u00f5es do corpo listadas<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ficha reta para cabo<\/td>\n<td>SP1710<\/td>\n<td>Comprimento 56.5; di\u00e2metro frontal \u00d824.6<\/td>\n<\/tr>\n<tr>\n<td>Recept\u00e1culo de cabo em linha<\/td>\n<td>SP1711<\/td>\n<td>Comprimento 56.5; di\u00e2metro frontal \u00d825<\/td>\n<\/tr>\n<tr>\n<td>Recept\u00e1culo de painel com porca traseira<\/td>\n<td>SP1712<\/td>\n<td>Comprimento 19.7; proje\u00e7\u00e3o frontal 10.7; di\u00e2metro frontal \u00d825; rosca de montagem M17 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Formato de tomada de parafuso<\/td>\n<td>SP1713<\/td>\n<td>Comprimento 19.7; proje\u00e7\u00e3o frontal 10.7; di\u00e2metro frontal \u00d825; rosca de montagem M17 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Square panel receptacle<\/td>\n<td>SP1714<\/td>\n<td>Length 22.0; front projection 11; flange thickness 4.0; flange vertical size 26.0; rear thread M16 \u00d7 1<\/td>\n<\/tr>\n<tr>\n<td>Flange panel receptacle<\/td>\n<td>SP1715<\/td>\n<td>Flange width 34.0; height 24.8; body spigot diameter \u00d816.0<\/td>\n<\/tr>\n<tr>\n<td>Right-angle cable plug<\/td>\n<td>SP1716<\/td>\n<td>Overall horizontal extent 57; vertical extent 51; front vertical extent 29.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Panel Opening Data<\/h3>\n<table>\n<thead>\n<tr>\n<th>Panel format<\/th>\n<th>Listed opening data<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP1712 \/ SP1713<\/td>\n<td>Keyed opening \u00d817 with 15.6 across flats; maximum panel thickness 3<\/td>\n<\/tr>\n<tr>\n<td>SP1715<\/td>\n<td>Central opening \u00d816.8; fixing holes \u00d83.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Check the complete mounting drawing before machining a panel, including fixing-hole positions and the required clearance around the connector.<\/p>\n<h2>Formatos de Conector e Sele\u00e7\u00e3o de Acoplamento<\/h2>\n<p>Each base model is shown in <strong>\/P<\/strong> e <strong>\/S<\/strong> contact versions. <strong>P identifies male pin contacts; S identifies female socket contacts.<\/strong> Contact gender is separate from whether the connector body is a cable plug or a receptacle.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo base<\/th>\n<th>Formato<\/th>\n<th>Matching base models<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP1710<\/td>\n<td>Ficha reta para cabo<\/td>\n<td>SP1711, SP1712, SP1713, SP1714, SP1715<\/td>\n<\/tr>\n<tr>\n<td>SP1711<\/td>\n<td>Recept\u00e1culo de cabo em linha<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1712<\/td>\n<td>Recept\u00e1culo de painel com porca traseira<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1713<\/td>\n<td>Formato de tomada de parafuso<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1714<\/td>\n<td>Square panel receptacle<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1715<\/td>\n<td>Flange panel receptacle<\/td>\n<td>SP1710, SP1716<\/td>\n<\/tr>\n<tr>\n<td>SP1716<\/td>\n<td>Right-angle cable plug<\/td>\n<td>SP1711, SP1712, SP1713, SP1714, SP1715<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose a compatible pin\/socket pair with the same contact count and arrangement. The table identifies mating body families, rather than a complete orderable part number.<\/p>\n<h2>Identifica\u00e7\u00e3o do Modelo e Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Por exemplo, <strong>SP1710\/P<\/strong> identifies the straight cable plug with pin contacts, while <strong>SP1711\/S<\/strong> identifies the inline cable receptacle with socket contacts. Contact count and termination still need to be specified.<\/p>\n<p>The SP1710 code legend identifies <strong>solder termination as code 1, normally unmarked<\/strong>, and <strong>crimp termination as code 3<\/strong>. State the required termination in an enquiry; do not select a crimp configuration solely from the solder rating table.<\/p>\n<ol>\n<li>Select the contact count and check its solder working voltage and rated current where applicable.<\/li>\n<li>Choose a straight or right-angle cable plug and a matching cable or panel receptacle.<\/li>\n<li>Specify P pin contacts or S socket contacts for each mating half.<\/li>\n<li>State the conductor size and termination method.<\/li>\n<li>State the cable outer diameter for each cable connector and the panel mounting format for each panel receptacle.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>For an SP17 enquiry, provide the <strong>base model, contact count, P\/S contact version, termination, conductor size, cable outer diameter and quantity<\/strong>. For panel receptacles, include the mounting format and available panel thickness. For right-angle plugs, include the cable exit direction and cable diameter so the corresponding seal configuration can be selected.<\/p>","protected":false},"excerpt":{"rendered":"<p>Conectores circulares YOCL EL\u00c9TRICOS SP17 \u00e0 prova de \u00e1gua fornecem liga\u00e7\u00f5es de cabo e painel roscadas com sete configura\u00e7\u00f5es de contacto.<\/p>\n<ul>\n<li>Contactos 2, 3, 4, 5, 7, 9 ou 10<\/li>\n<li>Grau de prote\u00e7\u00e3o IP68; intervalo de temperatura de \u221240 \u00b0C a +85 \u00b0C<\/li>\n<li>Pot\u00eancias de solda: 10 A para contactos 2\/3, 5 A para contactos 4\/5\/7\/9\/10<\/li>\n<li>Tens\u00e3o de trabalho: 500 V AC para contactos 2\u20135; 400 V AC para contactos 7\/9\/10, para configura\u00e7\u00f5es de solda<\/li>\n<li>Fichas retas e em \u00e2ngulo reto com formatos de recept\u00e1culo em linha e de painel<\/li>\n<\/ul>","protected":false},"featured_media":2815,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2818","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2815"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2818"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2818"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2818"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}