{"id":2822,"date":"2026-10-07T12:50:20","date_gmt":"2026-10-07T12:50:20","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2822"},"modified":"2026-10-07T12:50:30","modified_gmt":"2026-10-07T12:50:30","slug":"sp21-waterproof-circular-connectors","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/sp21-waterproof-circular-connectors\/","title":{"rendered":"Conectores Circulares \u00e0 Prova de \u00c1gua SP21"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>YOCL ELECTRIC SP21 Conectores Circulares \u00e0 Prova de \u00c1gua fornecem liga\u00e7\u00f5es el\u00e9tricas destac\u00e1veis cabo-a-cabo e cabo-a-painel com <strong>2, 3, 4, 5, 7, 9 ou 12 contactos<\/strong>. Uma acoplagem roscada fixa os corpos de acoplamento, enquanto as op\u00e7\u00f5es de contacto pino e tomada permitem selecionar o arranjo el\u00e9trico necess\u00e1rio.<\/p>\n<p>A gama inclui fichas de cabo retas e angulares, tomadas de cabo em linha, tomadas de painel com porca traseira e tomadas montadas em flange. As veda\u00e7\u00f5es de cabo est\u00e3o listadas para <strong>4.5\u20137 mm<\/strong> e <strong>7\u201312 mm<\/strong> di\u00e2metros exteriores do cabo. O cat\u00e1logo lista <strong>prote\u00e7\u00e3o IP68<\/strong>, com especifica\u00e7\u00f5es el\u00e9tricas e de termina\u00e7\u00e3o de fios selecionadas pela configura\u00e7\u00e3o de contacto.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li><strong>Bloqueio de rosca:<\/strong> Um acoplamento de parafuso une os corpos dos conectores correspondentes.<\/li>\n<li><strong>Sete op\u00e7\u00f5es de contagem de contactos:<\/strong> Selecione 2, 3, 4, 5, 7, 9 ou 12 contactos.<\/li>\n<li><strong>Estilos de corpo de cabo e painel:<\/strong> Fichas retas, liga\u00e7\u00f5es em linha, fichas angulares e tomadas de equipamento est\u00e3o listadas.<\/li>\n<li><strong>Contactos pino e tomada:<\/strong> As designa\u00e7\u00f5es P e S referem-se ao tipo de contacto el\u00e9trico.<\/li>\n<li><strong>Contactos de cobre banhados a ouro:<\/strong> O cat\u00e1logo especifica contactos de cobre com banho de ouro.<\/li>\n<li><strong>Termina\u00e7\u00e3o selecion\u00e1vel:<\/strong> S\u00e3o listadas vers\u00f5es de soldar, com terminal de parafuso e de crimpagem, com limites espec\u00edficos da configura\u00e7\u00e3o.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9rie<\/td>\n<td>SP21<\/td>\n<\/tr>\n<tr>\n<td>Tipo de conector<\/td>\n<td>Conetor circular \u00e0 prova de \u00e1gua<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de contactos<\/td>\n<td>2 \/ 3 \/ 4 \/ 5 \/ 7 \/ 9 \/ 12<\/td>\n<\/tr>\n<tr>\n<td>Acoplamento<\/td>\n<td>Bloqueio de rosca<\/td>\n<\/tr>\n<tr>\n<td>Tipos de contacto<\/td>\n<td>P: pino; S: tomada<\/td>\n<\/tr>\n<tr>\n<td>Materiais da caixa<\/td>\n<td>PC \/ PA66 termopl\u00e1stico<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de inflamabilidade do material da caixa<\/td>\n<td>V-0<\/td>\n<\/tr>\n<tr>\n<td>Isolador<\/td>\n<td>PPS termopl\u00e1stico<\/td>\n<\/tr>\n<tr>\n<td>Contactos<\/td>\n<td>Cobre banhado a ouro<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td>IP68, classifica\u00e7\u00e3o de cat\u00e1logo<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de ciclos de acoplamento de cat\u00e1logo<\/td>\n<td>500<\/td>\n<\/tr>\n<tr>\n<td>Intervalo de temperatura<\/td>\n<td>\u221240 \u00b0C a +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Resist\u00eancia de isolamento<\/td>\n<td>2000 M\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Dados de Contacto El\u00e9trico<\/h3>\n<p>Os seguintes valores prov\u00eam da tabela de par\u00e2metros de contactos de solda do cat\u00e1logo. N\u00e3o s\u00e3o uma especifica\u00e7\u00e3o separada para contactos de crimpagem.<\/p>\n<table>\n<thead>\n<tr>\n<th>Contactos<\/th>\n<th>Corrente nominal<\/th>\n<th>Di\u00e2metro do contacto \u00d7 contagem<\/th>\n<th>Tens\u00e3o de trabalho, AC<\/th>\n<th>Tens\u00e3o de suportabilidade, AC, 1 minuto<\/th>\n<th>Resist\u00eancia de contacto<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 2<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 3<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 4<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>\u2014<\/td>\n<td>\u00d83 mm \u00d7 5<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>15 A<\/td>\n<td>\u00d82 mm \u00d7 7<\/td>\n<td>500 V<\/td>\n<td>1500 V<\/td>\n<td>2.5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>5 A<\/td>\n<td>\u00d81 mm \u00d7 9<\/td>\n<td>400 V<\/td>\n<td>1500 V<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>5 A<\/td>\n<td>\u00d81 mm \u00d7 12<\/td>\n<td>400 V<\/td>\n<td>1200 V<\/td>\n<td>5 m\u03a9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Para configura\u00e7\u00f5es de dois a cinco contactos, obtenha a corrente nominal para a termina\u00e7\u00e3o selecionada e o n\u00famero da pe\u00e7a ao encomendar. A tens\u00e3o de trabalho e o valor de resist\u00eancia de um minuto descrevem par\u00e2metros diferentes.<\/p>\n<h3>Limites do condutor por termina\u00e7\u00e3o<\/h3>\n<table>\n<thead>\n<tr>\n<th>Contactos<\/th>\n<th>Limite do condutor de solda<\/th>\n<th>Entrada do cat\u00e1logo AWG<\/th>\n<th>Limite do condutor de terminal de parafuso<\/th>\n<th>Entrada do cat\u00e1logo AWG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2 \/ 3 \/ 4 \/ 5<\/td>\n<td>\u22644 mm\u00b2<\/td>\n<td>12 AWG<\/td>\n<td>\u22641.5 mm\u00b2<\/td>\n<td>15 AWG<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u22642 mm\u00b2<\/td>\n<td>14 AWG<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>9 \/ 12<\/td>\n<td>\u22640.75 mm\u00b2<\/td>\n<td>18 AWG<\/td>\n<td>\u2014<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Os limites m\u00e9tricos e as entradas AWG s\u00e3o reproduzidos como pares de cat\u00e1logo. Um travess\u00e3o significa que n\u00e3o \u00e9 fornecido limite de condutor para essa termina\u00e7\u00e3o nesta tabela. Selecione o tamanho do fio juntamente com o inserto de contato e a termina\u00e7\u00e3o. Os limites de condutor espec\u00edficos para crimpagem n\u00e3o s\u00e3o especificados aqui.<\/p>\n<h3>Sele\u00e7\u00e3o da Bainha do Cabo<\/h3>\n<table>\n<thead>\n<tr>\n<th>Estilos de corpo aplic\u00e1veis<\/th>\n<th>Di\u00e2metro exterior do cabo listado<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2110 fichas de cabo retas, SP2111 tomadas de cabo em linha e SP2116 fichas de cabo angulares<\/td>\n<td>4.5\u20137 mm ou 7\u201312 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>O cat\u00e1logo identifica a gama de cabos mais pequena como op\u00e7\u00e3o I e a gama maior como op\u00e7\u00e3o II; II n\u00e3o est\u00e1 marcada. Selecione a gama de veda\u00e7\u00e3o a partir do di\u00e2metro real da bainha do cabo.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp21-waterproof-circular-connectors-dimension.webp\" alt=\"SP21 Waterproof Circular Connectors dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/sp21-waterproof-circular-connectors-dimension-02.webp\" alt=\"SP21 Waterproof Circular Connectors dimension drawing\"><\/p>\n<h3>Dimens\u00f5es do Corpo do Conetor<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo base<\/th>\n<th>Dimens\u00f5es do corpo listadas<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2110 ficha de cabo reta<\/td>\n<td>65 mm comprimento total; \u00d829.3 mm di\u00e2metro frontal<\/td>\n<\/tr>\n<tr>\n<td>SP2111 tomada de cabo em linha<\/td>\n<td>65 mm comprimento total; \u00d829 mm di\u00e2metro frontal<\/td>\n<\/tr>\n<tr>\n<td>SP2112 \/ SP2113 tomadas de painel<\/td>\n<td>21.5 mm overall length; M21 \u00d7 1 mounting thread; panel thickness 3 mm max.<\/td>\n<\/tr>\n<tr>\n<td>SP2114 square-flange socket<\/td>\n<td>27 mm overall length; 30 mm flange height; 22 mm horizontal mounting-hole pitch<\/td>\n<\/tr>\n<tr>\n<td>SP2115 two-hole flange socket<\/td>\n<td>37.5 mm body width \u00d7 28.5 mm height; 31 mm hole pitch; \u00d83.6 mm body mounting holes; 21.5 mm overall length<\/td>\n<\/tr>\n<tr>\n<td>SP2116 angled cable plug<\/td>\n<td>57 mm horizontal overall length; 51 mm vertical overall height; 29.3 mm front dimension<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Dimens\u00f5es da Abertura do Painel<\/h3>\n<table>\n<thead>\n<tr>\n<th>Tomada de painel<\/th>\n<th>Abertura de painel listada<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2112 \/ SP2113<\/td>\n<td>\u00d821 mm opening with 19.8 mm flat-to-flat height<\/td>\n<\/tr>\n<tr>\n<td>SP2115<\/td>\n<td>\u00d821 mm central opening; two \u00d84 mm mounting holes on 31 mm centres<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Os furos do corpo do conetor e os furos de montagem no painel t\u00eam dimens\u00f5es separadas. Utilize o desenho de instala\u00e7\u00e3o completo da tomada selecionada para verificar a forma da abertura e a posi\u00e7\u00e3o dos furos.<\/p>\n<h2>Formatos de Conector e Fam\u00edlias de Acoplamento<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo do corpo da base<\/th>\n<th>Formato<\/th>\n<th>Fam\u00edlia de acoplamento listada<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SP2110<\/td>\n<td>Ficha reta para cabo<\/td>\n<td>SP2111 \/ SP2112 \/ SP2113 \/ SP2114 \/ SP2115<\/td>\n<\/tr>\n<tr>\n<td>SP2111<\/td>\n<td>Soquete de cabo em linha<\/td>\n<td>SP2110 \/ SP2116<\/td>\n<\/tr>\n<tr>\n<td>SP2112<\/td>\n<td>Soquete de painel com porca traseira<\/td>\n<td>SP2110 \/ SP2116<\/td>\n<\/tr>\n<tr>\n<td>SP2113<\/td>\n<td>Screw-terminal panel socket<\/td>\n<td>SP2110 \/ SP2116<\/td>\n<\/tr>\n<tr>\n<td>SP2114<\/td>\n<td>Tomada de painel com flange quadrada<\/td>\n<td>SP2110 \/ SP2116<\/td>\n<\/tr>\n<tr>\n<td>SP2115<\/td>\n<td>Tomada de painel com flange de dois furos<\/td>\n<td>SP2110 \/ SP2116<\/td>\n<\/tr>\n<tr>\n<td>SP2116<\/td>\n<td>Ficha de cabo angular<\/td>\n<td>SP2111 \/ SP2112 \/ SP2113 \/ SP2114 \/ SP2115<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Cada fam\u00edlia de corpos \u00e9 apresentada com <strong>Pino \/P<\/strong> e <strong>Soquete \/S<\/strong> contact options. Match the contact count and opposite electrical contact types as well as the body families when specifying a mating pair.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Use the base body model and contact designation, such as <strong>SP2110\/P<\/strong> for a straight cable plug with pin contacts or <strong>SP2114\/S<\/strong> for a square-flange body with socket contacts. These are catalogue base designations; contact count, cable seal range and termination must also be specified.<\/p>\n<p>The catalogue&#8217;s termination legend uses <strong>1 for soldering (unmarked)<\/strong>, <strong>2 for screw termination<\/strong> e <strong>3 for crimping<\/strong>. The presence of a termination in the legend does not establish that every body and contact-count combination is available in that form. Obtain the complete part number for the requested configuration.<\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<ol>\n<li>Select the body style and mating body family.<\/li>\n<li>Specify pin or socket contacts and the required contact count on both sides.<\/li>\n<li>Select the termination and conductor size using the applicable limits.<\/li>\n<li>Match the cable seal to the cable jacket diameter; for panel versions, use the format-specific opening dimensions.<\/li>\n<li>Specify the required current, AC working voltage, quantity and mating-part requirements. Obtain model-specific data for a crimp version or a two- to five-contact current rating.<\/li>\n<\/ol>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<ul>\n<li>Detachable equipment wiring.<\/li>\n<li>Inline cable connections.<\/li>\n<li>Panel-mounted electrical interfaces.<\/li>\n<li>Multi-contact power and signal connections.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC SP21 Conectores Circulares \u00e0 Prova de \u00c1gua fornecem interfaces de cabo e equipamento com bloqueio roscado e configura\u00e7\u00f5es de contacto selecion\u00e1veis.<\/p>\n<ul>\n<li><strong>2 \/ 3 \/ 4 \/ 5 \/ 7 \/ 9 \/ 12 contactos<\/strong>; op\u00e7\u00f5es de pinos e tomadas.<\/li>\n<li><strong>IP68 classifica\u00e7\u00e3o do cat\u00e1logo<\/strong> e <strong>\u221240 \u00b0C a +85 \u00b0C<\/strong> intervalo de temperatura.<\/li>\n<li>Contactos de cobre banhados a ouro com PC \/ PA66 inv\u00f3lucros e isoladores de PPS.<\/li>\n<li>Fichas de cabo retas e angulares, tomadas em linha e formatos de tomadas de painel.<\/li>\n<li><strong>4.5\u20137 mm ou 7\u201312 mm<\/strong> intervalos de revestimento do cabo.<\/li>\n<li>Op\u00e7\u00f5es de solda, terminal de parafuso e crimpagem dependem da configura\u00e7\u00e3o.<\/li>\n<\/ul>","protected":false},"featured_media":2819,"template":"","meta":[],"product_brand":[],"product_cat":[176],"product_tag":[],"class_list":["post-2822","product","type-product","status-publish","has-post-thumbnail","product_cat-sp-waterproof-connectors","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2822","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2819"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2822"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2822"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2822"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}