{"id":2846,"date":"2026-10-07T13:33:13","date_gmt":"2026-10-07T13:33:13","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2846"},"modified":"2026-10-07T13:35:45","modified_gmt":"2026-10-07T13:35:45","slug":"ip44-industrial-appliance-inlets","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ip44-industrial-appliance-inlets\/","title":{"rendered":"IP44 Tomadas Industriais para Aparelhos"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>As tomadas industriais YOCL ELECTRIC IP44 fornecem uma liga\u00e7\u00e3o de energia macho em m\u00e1quinas, equipamentos de distribui\u00e7\u00e3o e caixas de equipamentos. A fam\u00edlia abrange vers\u00f5es 16 A e 32 A em configura\u00e7\u00f5es 2P+E, 3P+E e 3P+N+E. As tomadas retas para painel e os designs de entrada de superf\u00edcie fechados est\u00e3o agrupados aqui para que a interface de alimenta\u00e7\u00e3o possa ser selecionada juntamente com o seu arranjo de montagem. Um conector de cabo f\u00eamea correspondente fornece a liga\u00e7\u00e3o de cabo destac\u00e1vel.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Vers\u00f5es IP44 para liga\u00e7\u00f5es industriais protegidas contra salpicos.<\/li>\n<li>Designs retos para painel em caixas padr\u00e3o e K, mais designs de superf\u00edcie com uma face de conector angular.<\/li>\n<li>Op\u00e7\u00f5es 16 A e 32 A com gamas de condutores indicadas para cada modelo.<\/li>\n<li>Posi\u00e7\u00e3o do contacto de terra 6h nas vers\u00f5es listadas.<\/li>\n<li>As caixas de contacto azuis e vermelhas distinguem as configura\u00e7\u00f5es el\u00e9tricas listadas.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>Entrada para equipamento industrial \/ entrada macho para equipamento<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de corrente nominal<\/td>\n<td>16 A, 32 A<\/td>\n<\/tr>\n<tr>\n<td>Configura\u00e7\u00f5es de contacto<\/td>\n<td>2P+E; 3P+E; 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00e3o do contacto de terra<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Montagem em painel ou montagem em superf\u00edcie com caixa, dependendo do modelo<\/td>\n<\/tr>\n<tr>\n<td>Interface de cabo de acoplamento<\/td>\n<td>Conector de cabo industrial f\u00eamea correspondente<\/td>\n<\/tr>\n<tr>\n<td>Capacidade do condutor<\/td>\n<td>Espec\u00edfico do modelo; ver tabela de sele\u00e7\u00e3o<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Sele\u00e7\u00e3o de Modelo<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Montagem \/ caixa<\/th>\n<th>Corrente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Caixa do contacto<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>Straight panel inlet, K housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>Straight panel inlet<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>Straight panel inlet<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>Surface inlet with angled face<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240 V<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>Surface inlet with angled face \u2014 L housing<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 V \/ 240\u2013415 V<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>P denotes a phase contact, N neutral and E protective earth. A dash means that no voltage is assigned in this selection table.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Lettered outline dimensions (mm)<\/th>\n<th>Fixed mounting geometry<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-613K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615K<\/td>\n<td>a=50, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625K<\/td>\n<td>a=59, b=60<\/td>\n<td>Flange width \u00d7 height (mm): 76 \u00d7 76; Fixing centres (mm): 60 \u00d7 60; Panel opening diameter (mm): 65; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-613<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-623<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-614<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-624<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-615<\/td>\n<td>a=41<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-625<\/td>\n<td>a=51<\/td>\n<td>Flange width \u00d7 height (mm): 70 \u00d7 70; Fixing centres (mm): 56 \u00d7 56; Panel opening diameter (mm): 46; Fixing hole diameter (mm): 5<\/td>\n<\/tr>\n<tr>\n<td>NM-513<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-513L<\/td>\n<td>a=125, b=71, c=43, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-523L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-514L<\/td>\n<td>a=130, b=72, c=49.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-524L<\/td>\n<td>a=139, b=81, c=58, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-515L<\/td>\n<td>a=130, b=77, c=55.5, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-525L<\/td>\n<td>a=143, b=83, c=63, \u03a6=3\u201318<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use the lettered dimensions with the matching inlet outline. Flange geometry and housing size differ between body versions; select the complete model code when checking installation space.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-02.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-appliance-inlets-dimension-03.webp\" alt=\"IP44 Industrial Appliance Inlets dimension drawing\"><\/p>\n<h2>Sele\u00e7\u00e3o de Liga\u00e7\u00e3o<\/h2>\n<p>Match rated current, contact configuration, voltage and earth-contact position at both sides of the connection. Select panel or surface mounting before comparing the housing dimensions. The IP rating applies to the correctly assembled connection with its compatible mating interface; maintain the specified sealing and closure arrangement.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>Send YOCL ELECTRIC the full model code, required quantity, supply voltage, contact configuration and installation arrangement. Include conductor cross-section and the mating cable connector when requesting a complete equipment power connection.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 tomadas industriais em vers\u00f5es 16 A e 32 A. Escolha contactos 2P+E, 3P+E ou 3P+N+E, montagem em painel ou \u00e0 superf\u00edcie e a capacidade de condutor correspondente na tabela de modelos.<\/p>","protected":false},"featured_media":2845,"template":"","meta":[],"product_brand":[],"product_cat":[53],"product_tag":[],"class_list":["post-2846","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-plugs","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2845"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2846"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2846"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2846"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}