{"id":2856,"date":"2026-10-07T13:58:16","date_gmt":"2026-10-07T13:58:16","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2856"},"modified":"2026-10-07T13:58:26","modified_gmt":"2026-10-07T13:58:26","slug":"ip44-industrial-cable-couplers","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ip44-industrial-cable-couplers\/","title":{"rendered":"IP44 Acopladores de Cabo Industriais"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>Os acopladores industriais YOCL ELECTRIC IP44 s\u00e3o conectores de cabo f\u00eamea para liga\u00e7\u00f5es de cabo industriais. Esta fam\u00edlia re\u00fane os modelos 16 A e 32 A atuais listados abaixo, com arranjos de contatos 2P+E, 3P+E e 3P+N+E. Cada modelo tem a sua pr\u00f3pria tens\u00e3o, posi\u00e7\u00e3o do rel\u00f3gio de contato de terra e design da caixa.<\/p>\n<p>A extremidade do conetor tem contatos f\u00eamea e uma tampa frontal protetora; a entrada traseira aceita o cabo de alimenta\u00e7\u00e3o. As vers\u00f5es com design H, design K, corpo traseiro branco e posi\u00e7\u00e3o especial do rel\u00f3gio permanecem grupos de modelos separados para que a fotografia da caixa e os dados dimensionais possam ser correspondidos ao conetor correto.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>IP44 classifica\u00e7\u00e3o de prote\u00e7\u00e3o para os modelos listados.<\/li>\n<li>Contatos f\u00eamea e uma tampa protetora para a extremidade do conetor de cabo.<\/li>\n<li>Op\u00e7\u00f5es de corrente nominal: 16 A e 32 A; as combina\u00e7\u00f5es reais s\u00e3o definidas pelas tabelas de modelos.<\/li>\n<li>As vers\u00f5es 2P+E, 3P+E e 3P+N+E s\u00e3o identificadas individualmente.<\/li>\n<li>Configura\u00e7\u00f5es de contacto de terra: 4h, 6h e 9h selecionados, de acordo com o modelo nomeado.<\/li>\n<li>Grupos de carca\u00e7as separados preservam a capacidade do condutor e os dados dimensionais de cada modelo.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>Conetores de cabo f\u00eamea<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Montado no cabo<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Correntes nominais<\/td>\n<td>16 A e 32 A<\/td>\n<\/tr>\n<tr>\n<td>Arranjos de contactos<\/td>\n<td>2P+E (3 contactos); 3P+E (4 contactos); 3P+N+E (5 contactos)<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00f5es de contacto de terra<\/td>\n<td>4h, 6h e 9h selecionados<\/td>\n<\/tr>\n<tr>\n<td>Configura\u00e7\u00f5es de tens\u00e3o<\/td>\n<td>Consulte as linhas de modelos individuais; as classifica\u00e7\u00f5es emparelhadas de cinco contactos s\u00e3o mantidas conforme listado.<\/td>\n<\/tr>\n<tr>\n<td>Capacidades dos condutores<\/td>\n<td>Model-specific values in mm\u00b2; see the selection tables.<\/td>\n<\/tr>\n<tr>\n<td>Housing designs<\/td>\n<td>See the separate model groups below.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Design de carca\u00e7a H \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Printed reference<\/th>\n<th>Corrente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>511<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>523<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>514<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>526<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>NM5<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>NM6<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Design de carca\u00e7a K \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Designs de corpo traseiro branco \u2014 16 \/ 32 A<\/h2>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>1\u20132.5<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>2.5\u20136<\/td>\n<td>Amarelo<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>1\u20132.5<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>2.5\u20136<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Layouts de contacto especiais 9h \u2014 16 \/ 32 A<\/h2>\n<p>These 9h models use the particular voltage and contact layouts shown below. Their conductor capacities and dimensions are not extended from the ordinary models.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Clock<\/th>\n<th>Conductor capacity (mm\u00b2)<\/th>\n<th>Body color<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213L-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-223L-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Vermelho<\/td>\n<\/tr>\n<tr>\n<td>NM-214L-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Azul<\/td>\n<\/tr>\n<tr>\n<td>NM-224L-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>\u2014<\/td>\n<td>Azul<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p>The symbols below reproduce each housing group\u2019s dimensional table in millimetres. Letter meanings differ between drawings; a repeated symbol does not define one common dimension across all groups. Match the full model code and housing group before using a drawing.<\/p>\n<h3>Design de carca\u00e7a H \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213H-4<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H-4<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-213H<\/td>\n<td>a = 155; b = 51.3; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-223H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-214H<\/td>\n<td>a = 156.5; b = 51.3; c = 61.2<\/td>\n<\/tr>\n<tr>\n<td>NM-224H<\/td>\n<td>a = 200; b = 64.2; c = 71.6<\/td>\n<\/tr>\n<tr>\n<td>NM-215H<\/td>\n<td>a = 161.7; b = 50.2; c = 69<\/td>\n<\/tr>\n<tr>\n<td>NM-225H<\/td>\n<td>a = 200; b = 70.8; c = 79.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design de carca\u00e7a K \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213K-4<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K-4<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-213K<\/td>\n<td>a = 134; b = 73; c = 51<\/td>\n<\/tr>\n<tr>\n<td>NM-223K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-214K<\/td>\n<td>a = 143; b = 80; c = 57<\/td>\n<\/tr>\n<tr>\n<td>NM-224K<\/td>\n<td>a = 167; b = 90; c = 66<\/td>\n<\/tr>\n<tr>\n<td>NM-215K<\/td>\n<td>a = 150; b = 82; c = 64<\/td>\n<\/tr>\n<tr>\n<td>NM-225K<\/td>\n<td>a = 167; b = 97; c = 72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Designs de corpo traseiro branco \u2014 16 \/ 32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Drawing\/table dimensions (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-213-4<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223-4<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213L<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223L<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-213<\/td>\n<td>a = 131; b = 69; c = 50.5; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-223<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-214<\/td>\n<td>a = 131; b = 79; c = 56; \u03c6 = 6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-224<\/td>\n<td>a = 152; b = 94; c = 65; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-215<\/td>\n<td>a = 141; b = 93; c = 64; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<tr>\n<td>NM-225<\/td>\n<td>a = 154; b = 101; c = 71; \u03c6 = 8\u201320<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-02.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-03.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-04.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-industrial-cable-couplers-dimension-05.webp\" alt=\"IP44 Industrial Cable Couplers dimension drawing\"><\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<p>Choose a female cable coupler when the mating connection is made at the end of a cable. A wall-mounted socket or an appliance inlet belongs to a different mounting and contact family.<\/p>\n<p>Select the current rating, contact arrangement, rated voltage, earth-contact clock position and IP rating together from one actual model row. Body color alone is insufficient: the special clock-position groups include different voltage\/contact combinations from the ordinary groups.<\/p>\n<p>Keep the complete suffix when selecting the housing version. Models that share an electrical rating may have different lengths, cable-entry dimensions or body shapes. Conductor capacity is a cross-sectional range in mm\u00b2 and must not be confused with a cable-entry dimension in mm.<\/p>\n<p>For five-contact models, the table preserves the paired 220\u2013380 \/ 240\u2013415 V notation. It does not create an additional arbitrary voltage combination. A dash in the capacity column means that the particular row supplies no confirmed value.<\/p>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>When enquiring about YOCL ELECTRIC IP44 industrial cable couplers, provide the full model code, quantity, current rating, contact arrangement, rated voltage, clock position and the required housing design. Include the conductor cross-section and cable outside diameter so that the cable entry and terminal range can be checked for that specific model.<\/p>\n<p>Printed secondary references identify the catalogue entries where shown; they do not create extra model options or replace the full NM model code.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 acopladores industriais para liga\u00e7\u00f5es de ponta de cabo, com designs de caixa distintos e tabelas completas de sele\u00e7\u00e3o de modelos NM.<\/p>\n<ul>\n<li>Correntes nominais: 16 A e 32 A.<\/li>\n<li>Arranjos de contactos: 2P+E, 3P+E e 3P+N+E.<\/li>\n<li>4h, 6h e 9h selecionadas de liga\u00e7\u00f5es de contacto de terra, dependendo do modelo.<\/li>\n<li>Conetor de cabo f\u00eamea com tampa frontal.<\/li>\n<li>Selecione a tens\u00e3o, a capacidade do condutor e as dimens\u00f5es pelo c\u00f3digo completo do modelo.<\/li>\n<\/ul>","protected":false},"featured_media":2850,"template":"","meta":[],"product_brand":[],"product_cat":[55],"product_tag":[],"class_list":["post-2856","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-couplers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2850"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2856"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2856"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}