{"id":2874,"date":"2026-10-07T14:14:08","date_gmt":"2026-10-07T14:14:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2874"},"modified":"2026-10-07T14:14:18","modified_gmt":"2026-10-07T14:14:18","slug":"ip44-surface-mounted-industrial-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ip44-surface-mounted-industrial-sockets\/","title":{"rendered":"IP44 Tomadas Industriais Montadas \u00e0 Superf\u00edcie"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>YOCL ELECTRIC IP44 tomadas industriais de montagem \u00e0 superf\u00edcie fornecem um ponto de liga\u00e7\u00e3o f\u00eamea fixo para fichas industriais compat\u00edveis. A s\u00e9rie inclui classifica\u00e7\u00f5es 16 \/ 32 A e arranjos de contactos 2P+E, 3P+E, 3P+N+E. Cada modelo combina uma corrente nominal espec\u00edfica, tens\u00e3o, posi\u00e7\u00e3o do contacto de terra e design da caixa.<\/p>\n<p>As tabelas de sele\u00e7\u00e3o mant\u00eam as vers\u00f5es de caixa dispon\u00edveis juntas numa fam\u00edlia de produtos. Utilize o c\u00f3digo de modelo NM completo para especificar a configura\u00e7\u00e3o el\u00e9trica e as dimens\u00f5es de instala\u00e7\u00e3o correspondentes.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Caixa traseira e estrutura de fixa\u00e7\u00e3o \u00e0 superf\u00edcie para uma instala\u00e7\u00e3o de tomada fixa.<\/li>\n<li>IP44 classifica\u00e7\u00e3o de prote\u00e7\u00e3o para os modelos listados.<\/li>\n<li>Tampa articulada na face da tomada.<\/li>\n<li>Configura\u00e7\u00f5es azul, vermelha e amarela listadas por modelo exato nas tabelas de sele\u00e7\u00e3o.<\/li>\n<li>Gamas de condutores e dimens\u00f5es de montagem espec\u00edficas do modelo para selecionar a liga\u00e7\u00e3o el\u00e9trica e o espa\u00e7o de instala\u00e7\u00e3o.<\/li>\n<li>As posi\u00e7\u00f5es alternativas do contacto de terra est\u00e3o listadas separadamente; associe a posi\u00e7\u00e3o de terra \u00e0 configura\u00e7\u00e3o da ficha pretendida.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>IP44 Tomadas Industriais Montadas \u00e0 Superf\u00edcie<\/td>\n<\/tr>\n<tr>\n<td>G\u00e9nero do contacto<\/td>\n<td>Tomada f\u00eamea<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Montagem \u00e0 superf\u00edcie<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o<\/td>\n<td>IP44<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de corrente nominal<\/td>\n<td>16 \/ 32 A<\/td>\n<\/tr>\n<tr>\n<td>Arranjos de contactos<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Configura\u00e7\u00f5es de tens\u00e3o<\/td>\n<td>110\u2013130 V; 220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00f5es de contacto de terra<\/td>\n<td>4h \/ 6h \/ 9h<\/td>\n<\/tr>\n<tr>\n<td>Sec\u00e7\u00e3o transversal do condutor<\/td>\n<td>Valores espec\u00edficos do modelo nas tabelas de sele\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Vers\u00f5es da caixa<\/td>\n<td>Caixa H, 16\/32 A; Caixa K, 16\/32 A; Caixa Standard, 16\/32 A; Caixa L longa, 16\/32 A; 9h configura\u00e7\u00f5es especiais<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de modelo<\/td>\n<td>32<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabelas de Sele\u00e7\u00e3o de Modelos<\/h2>\n<p>Os valores de tens\u00e3o e corrente pertencem \u00e0 linha exata do modelo. Um tra\u00e7o indica que n\u00e3o existe um valor espec\u00edfico do modelo nos dados fornecidos.<\/p>\n<h3>Caixa H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113H-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123H-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-113H<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123H<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-114H<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-124H<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-115H<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-125H<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>K housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113K-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123K-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-113K<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123K<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-114K<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-124K<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-115K<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-125K<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Caixa standard, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-113<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-114<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-124<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-115<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-125<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Long L housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113L<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-123L<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>9h special configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113-9<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>Vermelho<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-123-9<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>380\u2013415<\/td>\n<td>9h<\/td>\n<td>Vermelho<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-114-9<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>Azul<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-124-9<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>Azul<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-115-9<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>Azul<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-125-9<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013240<\/td>\n<td>9h<\/td>\n<td>Azul<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p>As letras de dimens\u00e3o aplicam-se ao desenho da caixa individual. A mesma letra pode identificar uma caracter\u00edstica diferente noutra vers\u00e3o da caixa. Selecione as dimens\u00f5es de montagem a partir da linha do modelo exato.<\/p>\n<h3>Caixa H, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>e (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113H-4<\/td>\n<td>87<\/td>\n<td>64<\/td>\n<td>110<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>NM-123H-4<\/td>\n<td>128<\/td>\n<td>84<\/td>\n<td>147<\/td>\n<td>68<\/td>\n<\/tr>\n<tr>\n<td>NM-113H<\/td>\n<td>87<\/td>\n<td>64<\/td>\n<td>110<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>NM-123H<\/td>\n<td>128<\/td>\n<td>84<\/td>\n<td>147<\/td>\n<td>68<\/td>\n<\/tr>\n<tr>\n<td>NM-114H<\/td>\n<td>100<\/td>\n<td>75<\/td>\n<td>125<\/td>\n<td>59<\/td>\n<\/tr>\n<tr>\n<td>NM-124H<\/td>\n<td>128<\/td>\n<td>84<\/td>\n<td>147<\/td>\n<td>68<\/td>\n<\/tr>\n<tr>\n<td>NM-115H<\/td>\n<td>100<\/td>\n<td>75<\/td>\n<td>131<\/td>\n<td>59<\/td>\n<\/tr>\n<tr>\n<td>NM-125H<\/td>\n<td>128<\/td>\n<td>84<\/td>\n<td>152<\/td>\n<td>68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>K housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113K-4<\/td>\n<td>149<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>NM-123K-4<\/td>\n<td>163<\/td>\n<td>107<\/td>\n<\/tr>\n<tr>\n<td>NM-113K<\/td>\n<td>149<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>NM-123K<\/td>\n<td>163<\/td>\n<td>107<\/td>\n<\/tr>\n<tr>\n<td>NM-114K<\/td>\n<td>150<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>NM-124K<\/td>\n<td>163<\/td>\n<td>107<\/td>\n<\/tr>\n<tr>\n<td>NM-115K<\/td>\n<td>153<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-125K<\/td>\n<td>163<\/td>\n<td>113<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 82; fixing width 71; vertical spacings 16, 47 and 40; side drawing 103.<\/p>\n<h3>Caixa standard, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>\u03c6 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113-4<\/td>\n<td>135<\/td>\n<td>92<\/td>\n<td>50<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-123-4<\/td>\n<td>153<\/td>\n<td>102<\/td>\n<td>65<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-113<\/td>\n<td>135<\/td>\n<td>92<\/td>\n<td>50<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-123<\/td>\n<td>153<\/td>\n<td>102<\/td>\n<td>65<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-114<\/td>\n<td>140<\/td>\n<td>95<\/td>\n<td>56<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-124<\/td>\n<td>152<\/td>\n<td>104<\/td>\n<td>65<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-115<\/td>\n<td>139<\/td>\n<td>96<\/td>\n<td>63<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-125<\/td>\n<td>153<\/td>\n<td>107<\/td>\n<td>70<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 71; fixing width 58; vertical spacings 15 and 33.<\/p>\n<h3>Long L housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>\u03c6 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-113L<\/td>\n<td>168<\/td>\n<td>92<\/td>\n<td>50<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<tr>\n<td>NM-123L<\/td>\n<td>190<\/td>\n<td>102<\/td>\n<td>65<\/td>\n<td>3\u201318<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 71; fixing width 58; vertical spacings 15 and 33.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-surface-mounted-industrial-sockets-dimension.webp\" alt=\"IP44 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-surface-mounted-industrial-sockets-dimension-02.webp\" alt=\"IP44 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-surface-mounted-industrial-sockets-dimension-03.webp\" alt=\"IP44 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-surface-mounted-industrial-sockets-dimension-04.webp\" alt=\"IP44 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip44-surface-mounted-industrial-sockets-dimension-05.webp\" alt=\"IP44 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<ol>\n<li>Escolha a corrente nominal e a configura\u00e7\u00e3o de contactos necess\u00e1ria para a liga\u00e7\u00e3o.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP44 tomadas industriais de montagem \u00e0 superf\u00edcie para liga\u00e7\u00f5es el\u00e9tricas industriais fixas.<\/p>\n<ul>\n<li>Intensidades nominais: 16 \/ 32 A.<\/li>\n<li>Configura\u00e7\u00f5es de contactos: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Tomada f\u00eamea com tampa articulada e caixa de montagem traseira.<\/li>\n<li>As tabelas completas de sele\u00e7\u00e3o de modelos incluem tens\u00e3o, posi\u00e7\u00e3o do contacto de terra, gamas de condutores e dimens\u00f5es espec\u00edficas da caixa.<\/li>\n<li>Selecione e consulte pelo c\u00f3digo completo do modelo NM.<\/li>\n<\/ul>","protected":false},"featured_media":2868,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2874","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2868"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2874"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2874"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2874"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}