{"id":2897,"date":"2026-10-07T14:39:08","date_gmt":"2026-10-07T14:39:08","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2897"},"modified":"2026-10-07T14:39:17","modified_gmt":"2026-10-07T14:39:17","slug":"ip67-straight-panel-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ip67-straight-panel-sockets\/","title":{"rendered":"IP67 Tomadas retas montadas em painel"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>As tomadas industriais retas montadas em painel YOCL IP67 fornecem um ponto de liga\u00e7\u00e3o f\u00eamea fixo para fichas industriais compat\u00edveis. A s\u00e9rie inclui classifica\u00e7\u00f5es 16 \/ 32 \/ 63 \/ 125 A e arranjos de contactos 2P+E, 3P+E, 3P+N+E. Cada modelo combina uma corrente nominal espec\u00edfica, tens\u00e3o, posi\u00e7\u00e3o do contacto de terra e design da caixa.<\/p>\n<p>As tabelas de sele\u00e7\u00e3o mant\u00eam as vers\u00f5es de caixa dispon\u00edveis juntas numa fam\u00edlia de produtos. Utilize o c\u00f3digo de modelo NM completo para especificar a configura\u00e7\u00e3o el\u00e9trica e as dimens\u00f5es de instala\u00e7\u00e3o correspondentes.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Eixo da tomada reta e flange de montagem para instala\u00e7\u00e3o em painel.<\/li>\n<li>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o IP67 para os modelos listados.<\/li>\n<li>Tampa articulada na face da tomada.<\/li>\n<li>Configura\u00e7\u00f5es azuis e vermelhas listadas por modelo exato nas tabelas de sele\u00e7\u00e3o.<\/li>\n<li>Gamas de condutores e dimens\u00f5es de montagem espec\u00edficas do modelo para selecionar a liga\u00e7\u00e3o el\u00e9trica e o espa\u00e7o de instala\u00e7\u00e3o.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>IP67 Tomadas retas montadas em painel<\/td>\n<\/tr>\n<tr>\n<td>G\u00e9nero do contacto<\/td>\n<td>Tomada f\u00eamea<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Montada em painel reta<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de corrente nominal<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Arranjos de contactos<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Configura\u00e7\u00f5es de tens\u00e3o<\/td>\n<td>220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00f5es de contacto de terra<\/td>\n<td>6h<\/td>\n<\/tr>\n<tr>\n<td>Sec\u00e7\u00e3o transversal do condutor<\/td>\n<td>Valores espec\u00edficos do modelo nas tabelas de sele\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Vers\u00f5es da caixa<\/td>\n<td>Caixa 1, 16\/32 A; Caixa 2, 63\/125 A; Caixa 2, 16\/32 A; Caixa standard, 63\/125 A<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de modelo<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabelas de Sele\u00e7\u00e3o de Modelos<\/h2>\n<p>Os valores de tens\u00e3o e corrente pertencem \u00e0 linha exata do modelo. Um tra\u00e7o indica que n\u00e3o existe um valor espec\u00edfico do modelo nos dados fornecidos.<\/p>\n<h3>Caixa de design 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p>As letras de dimens\u00e3o aplicam-se ao desenho da caixa individual. A mesma letra pode identificar uma caracter\u00edstica diferente noutra vers\u00e3o da caixa. Selecione as dimens\u00f5es de montagem a partir da linha do modelo exato.<\/p>\n<h3>Caixa de design 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3131<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-3231<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3141<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-3241<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-3151<\/td>\n<td>76<\/td>\n<td>76<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>NM-3251<\/td>\n<td>76<\/td>\n<td>85<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a, b (mm)<\/th>\n<th>c, d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-3332<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3432<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3342<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3442<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3352<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>48<\/td>\n<td>83<\/td>\n<td>116<\/td>\n<td>\u2014<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>NM-3452<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>45<\/td>\n<td>104<\/td>\n<td>127<\/td>\n<td>100<\/td>\n<td>7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-4132<\/td>\n<td>56<\/td>\n<td>83<\/td>\n<\/tr>\n<tr>\n<td>NM-4232<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4142<\/td>\n<td>56<\/td>\n<td>89<\/td>\n<\/tr>\n<tr>\n<td>NM-4242<\/td>\n<td>65<\/td>\n<td>97<\/td>\n<\/tr>\n<tr>\n<td>NM-4152<\/td>\n<td>56<\/td>\n<td>92<\/td>\n<\/tr>\n<tr>\n<td>NM-4252<\/td>\n<td>67<\/td>\n<td>105<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Flange 76 \u00d7 76; fixing centres 60 \u00d7 60; circular opening \u00d865; fixing holes \u00d85.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<th>h (mm)<\/th>\n<th>i (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-333<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-343<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-334<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-344<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-335<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>80<\/td>\n<td>80<\/td>\n<td>57<\/td>\n<td>86<\/td>\n<td>115<\/td>\n<td>109<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td>NM-345<\/td>\n<td>120<\/td>\n<td>120<\/td>\n<td>100<\/td>\n<td>100<\/td>\n<td>65<\/td>\n<td>96<\/td>\n<td>130<\/td>\n<td>124<\/td>\n<td>88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-02.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-03.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-straight-panel-mounted-sockets-dimension-04.webp\" alt=\"IP67 Straight Panel-Mounted Sockets dimension drawing\"><\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<ol>\n<li>Escolha a corrente nominal e a configura\u00e7\u00e3o de contactos necess\u00e1ria para a liga\u00e7\u00e3o.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL Tomadas industriais retas montadas em painel IP67 para liga\u00e7\u00f5es el\u00e9tricas industriais fixas.<\/p>\n<ul>\n<li>Intensidades nominais: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Configura\u00e7\u00f5es de contactos: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Tomada f\u00eamea com tampa articulada e flange de montagem em painel.<\/li>\n<li>As tabelas completas de sele\u00e7\u00e3o de modelos incluem tens\u00e3o, posi\u00e7\u00e3o do contacto de terra, gamas de condutores e dimens\u00f5es espec\u00edficas da caixa.<\/li>\n<li>Selecione e consulte pelo c\u00f3digo completo do modelo NM.<\/li>\n<\/ul>","protected":false},"featured_media":2892,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2897","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2892"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2897"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2897"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2897"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}