{"id":2904,"date":"2026-10-07T14:42:24","date_gmt":"2026-10-07T14:42:24","guid":{"rendered":"https:\/\/yocl.com\/?post_type=product&#038;p=2904"},"modified":"2026-10-07T14:42:33","modified_gmt":"2026-10-07T14:42:33","slug":"ip67-surface-mounted-industrial-sockets","status":"publish","type":"product","link":"https:\/\/yocl.com\/pt\/product\/ip67-surface-mounted-industrial-sockets\/","title":{"rendered":"IP67 Tomadas Industriais de Montagem \u00e0 Superf\u00edcie"},"content":{"rendered":"<h2>Vis\u00e3o Geral<\/h2>\n<p>As tomadas industriais de montagem \u00e0 superf\u00edcie YOCL ELECTRIC IP67 fornecem um ponto de liga\u00e7\u00e3o f\u00eamea fixo para fichas industriais compat\u00edveis. A s\u00e9rie inclui classifica\u00e7\u00f5es 16 \/ 32 \/ 63 \/ 125 A e arranjos de contactos 2P+E, 3P+E, 3P+N+E. Cada modelo combina uma corrente nominal espec\u00edfica, tens\u00e3o, posi\u00e7\u00e3o do contacto de terra e design da caixa.<\/p>\n<p>As tabelas de sele\u00e7\u00e3o mant\u00eam as vers\u00f5es de caixa dispon\u00edveis juntas numa fam\u00edlia de produtos. Utilize o c\u00f3digo de modelo NM completo para especificar a configura\u00e7\u00e3o el\u00e9trica e as dimens\u00f5es de instala\u00e7\u00e3o correspondentes.<\/p>\n<h2>Caracter\u00edsticas<\/h2>\n<ul>\n<li>Caixa traseira e estrutura de fixa\u00e7\u00e3o \u00e0 superf\u00edcie para uma instala\u00e7\u00e3o de tomada fixa.<\/li>\n<li>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o IP67 para os modelos listados.<\/li>\n<li>Tampa articulada na face da tomada.<\/li>\n<li>Configura\u00e7\u00f5es azul, vermelha e amarela listadas por modelo exato nas tabelas de sele\u00e7\u00e3o.<\/li>\n<li>Gamas de condutores e dimens\u00f5es de montagem espec\u00edficas do modelo para selecionar a liga\u00e7\u00e3o el\u00e9trica e o espa\u00e7o de instala\u00e7\u00e3o.<\/li>\n<li>As posi\u00e7\u00f5es alternativas do contacto de terra est\u00e3o listadas separadamente; associe a posi\u00e7\u00e3o de terra \u00e0 configura\u00e7\u00e3o da ficha pretendida.<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es T\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Marca<\/td>\n<td>YOCL EL\u00c9TRICO<\/td>\n<\/tr>\n<tr>\n<td>Tipo de produto<\/td>\n<td>IP67 Tomadas Industriais de Montagem \u00e0 Superf\u00edcie<\/td>\n<\/tr>\n<tr>\n<td>G\u00e9nero do contacto<\/td>\n<td>Tomada f\u00eamea<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Montagem \u00e0 superf\u00edcie<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o de prote\u00e7\u00e3o<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de corrente nominal<\/td>\n<td>16 \/ 32 \/ 63 \/ 125 A<\/td>\n<\/tr>\n<tr>\n<td>Arranjos de contactos<\/td>\n<td>2P+E \/ 3P+E \/ 3P+N+E<\/td>\n<\/tr>\n<tr>\n<td>Configura\u00e7\u00f5es de tens\u00e3o<\/td>\n<td>110\u2013130 V; 220\u2013240 V; 380\u2013415 V; 220\u2013380 \/ 240\u2013415 V<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00f5es de contacto de terra<\/td>\n<td>4h \/ 6h \/ 3h<\/td>\n<\/tr>\n<tr>\n<td>Sec\u00e7\u00e3o transversal do condutor<\/td>\n<td>Valores espec\u00edficos do modelo nas tabelas de sele\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Vers\u00f5es da caixa<\/td>\n<td>Caixa de design 1, 16\/32 A; Caixa de design 2, 63\/125 A; Caixa de design 2, 16\/32 A; Caixa standard, 63\/125 A; Configura\u00e7\u00f5es especiais 3h<\/td>\n<\/tr>\n<tr>\n<td>Op\u00e7\u00f5es de modelo<\/td>\n<td>28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Tabelas de Sele\u00e7\u00e3o de Modelos<\/h2>\n<p>Os valores de tens\u00e3o e corrente pertencem \u00e0 linha exata do modelo. Um tra\u00e7o indica que n\u00e3o existe um valor espec\u00edfico do modelo nos dados fornecidos.<\/p>\n<h3>Caixa de design 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>110\u2013130<\/td>\n<td>4h<\/td>\n<td>Amarelo<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>16<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>32<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>16<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>1\u20132.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>32<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>2.5\u20136<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>63<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>125<\/td>\n<td>2P+E<\/td>\n<td>220\u2013240<\/td>\n<td>6h<\/td>\n<td>Azul<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>63<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>125<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>63<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>6\u201316<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>125<\/td>\n<td>3P+N+E<\/td>\n<td>220\u2013380 \/ 240\u2013415<\/td>\n<td>6h<\/td>\n<td>Vermelho<\/td>\n<td>16\u201350<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3h special configurations<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>Corrente nominal (A)<\/th>\n<th>Contactos<\/th>\n<th>Tens\u00e3o (V)<\/th>\n<th>Posi\u00e7\u00e3o terra<\/th>\n<th>Cor<\/th>\n<th>Conductor cross-section (mm\u00b2)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1142-3<\/td>\n<td>16<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>Vermelho<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<tr>\n<td>NM-1242-3<\/td>\n<td>32<\/td>\n<td>3P+E<\/td>\n<td>380\u2013415<\/td>\n<td>3h<\/td>\n<td>Vermelho<\/td>\n<td>\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00e3o<\/h2>\n<p>As letras de dimens\u00e3o aplicam-se ao desenho da caixa individual. A mesma letra pode identificar uma caracter\u00edstica diferente noutra vers\u00e3o da caixa. Selecione as dimens\u00f5es de montagem a partir da linha do modelo exato.<\/p>\n<h3>Caixa de design 1, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>e1 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1131-4<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231-4<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1131<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>115<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1231<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1141<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1241<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>143<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<tr>\n<td>NM-1151<\/td>\n<td>95<\/td>\n<td>102<\/td>\n<td>124<\/td>\n<td>64.2<\/td>\n<td>77.5<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>NM-1251<\/td>\n<td>120<\/td>\n<td>112<\/td>\n<td>150<\/td>\n<td>90.2<\/td>\n<td>79<\/td>\n<td>98.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1332<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1432<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1342<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1442<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<tr>\n<td>NM-1352<\/td>\n<td>176<\/td>\n<td>171<\/td>\n<td>225<\/td>\n<td>119<\/td>\n<td>136<\/td>\n<td>103<\/td>\n<\/tr>\n<tr>\n<td>NM-1452<\/td>\n<td>180<\/td>\n<td>260<\/td>\n<td>305<\/td>\n<td>160<\/td>\n<td>241<\/td>\n<td>141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Design 2 housing, 16\/32 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-1132<\/td>\n<td>145<\/td>\n<td>99<\/td>\n<\/tr>\n<tr>\n<td>NM-1232<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1142<\/td>\n<td>150<\/td>\n<td>101<\/td>\n<\/tr>\n<tr>\n<td>NM-1242<\/td>\n<td>160<\/td>\n<td>108<\/td>\n<\/tr>\n<tr>\n<td>NM-1152<\/td>\n<td>150<\/td>\n<td>106<\/td>\n<\/tr>\n<tr>\n<td>NM-1252<\/td>\n<td>161<\/td>\n<td>111<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Base width 82; fixing width 71; vertical spacings 16, 48 and 40; side drawing 103.<\/p>\n<h3>Standard housing, 63\/125 A<\/h3>\n<table>\n<thead>\n<tr>\n<th>Modelo<\/th>\n<th>a (mm)<\/th>\n<th>b (mm)<\/th>\n<th>c (mm)<\/th>\n<th>d (mm)<\/th>\n<th>e (mm)<\/th>\n<th>f (mm)<\/th>\n<th>g (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>NM-133<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-143<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-134<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-144<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<tr>\n<td>NM-135<\/td>\n<td>134<\/td>\n<td>311<\/td>\n<td>108<\/td>\n<td>111<\/td>\n<td>20<\/td>\n<td>155<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>NM-145<\/td>\n<td>154<\/td>\n<td>338<\/td>\n<td>122<\/td>\n<td>130<\/td>\n<td>20<\/td>\n<td>187<\/td>\n<td>6.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional drawing dimensions (mm): Cable-entry drawing PG29.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-02.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-03.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-04.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/yocl.com\/wp-content\/uploads\/2026\/10\/ip67-surface-mounted-industrial-sockets-dimension-05.webp\" alt=\"IP67 Surface-Mounted Industrial Sockets dimension drawing\"><\/p>\n<h2>Guia de Sele\u00e7\u00e3o<\/h2>\n<ol>\n<li>Escolha a corrente nominal e a configura\u00e7\u00e3o de contactos necess\u00e1ria para a liga\u00e7\u00e3o.<\/li>\n<li>Match the voltage configuration and earth contact position to the mating plug. Colour alone is insufficient for model selection.<\/li>\n<li>Select the housing version and use its own mounting and conductor-range values.<\/li>\n<li>Include the complete model code and quantity in the enquiry.<\/li>\n<\/ol>\n<h2>Informa\u00e7\u00f5es de Encomenda<\/h2>\n<p>For a quotation, provide the complete NM model code, required quantity and mounting version. If identifying a replacement, include a photograph of the existing contact face and mounting layout.<\/p>","protected":false},"excerpt":{"rendered":"<p>YOCL ELECTRIC IP67 tomadas industriais de montagem \u00e0 superf\u00edcie para liga\u00e7\u00f5es el\u00e9tricas industriais fixas.<\/p>\n<ul>\n<li>Intensidades nominais: 16 \/ 32 \/ 63 \/ 125 A.<\/li>\n<li>Configura\u00e7\u00f5es de contactos: 2P+E \/ 3P+E \/ 3P+N+E.<\/li>\n<li>Tomada f\u00eamea com tampa articulada e caixa de montagem traseira.<\/li>\n<li>As tabelas completas de sele\u00e7\u00e3o de modelos incluem tens\u00e3o, posi\u00e7\u00e3o do contacto de terra, gamas de condutores e dimens\u00f5es espec\u00edficas da caixa.<\/li>\n<li>Selecione e consulte pelo c\u00f3digo completo do modelo NM.<\/li>\n<\/ul>","protected":false},"featured_media":2898,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[],"class_list":["post-2904","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-sockets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product\/2904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media\/2898"}],"wp:attachment":[{"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/media?parent=2904"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2904"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2904"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/yocl.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}